1. Introduzzjoni
1.1 Prodott Fuqview
The Blodgett R2506 Time Relay Kit is an essential component designed for precise timing control in Blodgett K4, K5, and K7 oven models. This electromechanical relay ensures accurate operation of oven functions that require timed sequences, contributing to consistent cooking results and operational efficiency. It is built for durability and reliable performance in commercial kitchen environments.
1.2 Informazzjoni dwar is-Sigurtà
TWISSIJA: Electrical components can be hazardous. Installation, maintenance, and troubleshooting should only be performed by qualified and certified personnel. Disconnect power to the appliance before servicing. Failure to follow these instructions may result in electrical shock, fire, or serious injury. Always adhere to local electrical codes and regulations.
2. Kontenut tal-Pakkett
Verify that all components are present and undamaged upon opening the package. The Blodgett R2506 Time Relay Kit typically includes:
- 1 x Blodgett R2506 Time Relay Unit
- Associated wiring (as pre-attached or included)
- Installation instructions/diagram (if not part of this manual)
3. Speċifikazzjonijiet
| Karatteristika | Dettall |
|---|---|
| Numru tal-Mudell | BLR2506 |
| Tip ta' Prodott | Time Relay Kit |
| Kompatibilità | Blodgett K4, K5, K7 Oven Models |
| Dimensjonijiet tal-Pakkett | 8 x 6 x 4 pulzieri |
| Piż tal-oġġett | 0.4 lbs (4.8 uqija) |
| Pajjiż ta' Oriġini | Istati Uniti |
| Tip ta' Konnettur | Invita |
| Kuntatt Materjal | Fidda |
| Tip ta 'Immuntar | Immonta fuq il-Panew |
| Mod ta' Operazzjoni | Awtomatiku |
4. Setup u Installazzjoni
Installation of the Blodgett R2506 Time Relay Kit requires electrical expertise. It is strongly recommended that installation be performed by a qualified service technician to ensure proper function and safety.
4.1 Linji Gwida Ġenerali dwar l-Installazzjoni
- Skonnettja l-Enerġija: Before beginning any installation, ensure the oven is completely disconnected from its power source.
- Panel ta' Aċċess: Locate and open the access panel on your Blodgett K4, K5, or K7 oven where the existing time relay is situated or where the new relay is to be installed.
- Identifika Komponenti: Carefully identify the existing relay (if replacing) and its associated wiring. Take photos for reference if needed.
- Immuntar: The relay is designed for panel mounting. Secure the new R2506 relay firmly in the designated mounting location within the oven's control panel.
4.2 Konnessjonijiet tal-Wiring
The R2506 Time Relay uses screw-type connectors for secure electrical connections. Refer to the wiring diagram provided with your specific oven model or the relay kit for precise connection points. Ensure all connections are tight and correct to prevent electrical hazards or malfunction.

Figura 1: Quddiem view of the Blodgett R2506 Time Relay Kit, showing the main unit with pre-attached wires and protective orange caps on terminals.

Figura 2: Ġenb view of the Blodgett R2506 Time Relay Kit, highlighting the wiring connections and the overall compact design.

Figura 3: Angolat view of the Blodgett R2506 Time Relay Kit, providing a clearer look at the internal circuit diagrams printed on the casing.

Figura 4: Minn fuq għal isfel view of the Blodgett R2506 Time Relay Kit, showing the adjustable control dial for setting timing parameters.
4.3 Kontroll ta' wara l-installazzjoni
After installation, secure the access panel. Before restoring power, double-check all connections and ensure no tools or loose items are left inside the oven's control area. Restore power and test the oven's timed functions to confirm proper operation of the new relay.
5. Operazzjoni
The Blodgett R2506 Time Relay operates automatically, as indicated by its specifications. Its primary function is to control the duration of specific oven cycles or components based on pre-set timing parameters.
5.1 Funzjonalità Bażika
Once installed and powered, the relay receives signals from the oven's control system to initiate a timed sequence. It then maintains a circuit connection for the programmed duration before automatically switching off or on, depending on its specific role within the oven's operation.
5.2 Issettjar tat-Tajmer
The R2506 relay features an adjustable dial (visible in Figure 4) that allows for setting the desired time delay or duration. The specific range and increments for timing adjustments will be marked on the dial itself. Consult your oven's main user manual for instructions on how to calibrate or set the timing for specific cooking programs or functions that utilize this relay.
6. Manutenzjoni
The Blodgett R2506 Time Relay Kit is designed for minimal maintenance. However, periodic inspection can help ensure its longevity and reliable performance.
- Spezzjoni Viżwali: Annually, or as part of routine oven maintenance, visually inspect the relay for any signs of physical damage, discoloration from overheating, or loose connections.
- Tindif: Ensure the area around the relay is free from dust, grease, and debris. Use a dry, soft cloth or a gentle brush to clean the exterior of the relay. Do not use liquid cleaners directly on the component.
- Servizzi Professjonali: Any internal issues or suspected malfunctions should be addressed by a qualified service technician. Do not attempt to open or repair the relay yourself.
7 Issolvi l-problemi
If the oven's timed functions are not operating correctly, the time relay may be a contributing factor. Always ensure power is disconnected before inspecting components.
| Problema | Kawża Possibbli | Soluzzjoni |
|---|---|---|
| Timed function does not activate. | No power to relay, faulty wiring, relay failure. | Verify power supply to the oven. Check all wiring connections for tightness and continuity. If connections are good, the relay may need replacement by a qualified technician. |
| Timed function activates but does not turn off. | Relay contacts stuck, internal relay failure. | This indicates an internal fault with the relay. Replacement by a qualified technician is required. |
| Inaccurate timing. | Incorrect dial setting, internal relay calibration issue. | Ensure the dial is set correctly according to oven specifications. If the issue persists, the relay may be faulty and require replacement. |
| Burning smell or visible damage. | Overheating, short circuit, component failure. | Immediately disconnect power. Do not attempt to operate the oven. Contact a qualified service technician for inspection and repair/replacement. |
For issues not listed above, or if troubleshooting steps do not resolve the problem, contact Blodgett customer support or a certified service technician.
8. Garanzija u Appoġġ
8.1 Garanzija tal-Manifattur
The Blodgett R2506 Time Relay Kit is covered by a manufacturer's warranty against defects in materials and workmanship. The specific terms and duration of the warranty may vary. Please refer to the warranty documentation included with your purchase or visit the official Blodgett websit għal informazzjoni dettaljata.
8.2 Appoġġ għall-Klijent
For technical assistance, parts inquiries, or warranty claims, please contact Blodgett customer support. Have your product model number (BLR2506) and purchase information ready when contacting support.
Blodgett Official Websit: www.blodgett.com
(Contact information such as phone numbers or specific email addresses may be found on the official website or your purchase invoice.)