SoliTek SOLID Series Solar Modules Installation Guide

SoliTek SOLID Series Solar Modules Installation Guide

SoliTek-LOGO

SoliTek SOLID Series Solar Modules

SoliTek-SOLID-Series-Solar-Modules-PRODUCT

Istruzzjonijiet għall-Użu

  • Read this guide entirely before installation.
  • This document provides minimum requirements and recommendations for safe and successful installation of SoliTek PV modules and is necessary to retain compliance with IEC 61215, IEC 61730, and UL 61730 standards.
  • This guide provides basic information on JSC SoliTek Cells SOLID series photovoltaic modules, including their installation and safe handling.
  • All instructions should be read and understood before attempting installation. Contact your dealer or JSC SoliTek Cells for further information if needed.
  • This documentation refers to the PV modules themselves and is not a comprehensive installation manual for personnel not specifically trained in PV modules.
  • It serves as a general but strictly mandatory reference for the installer. Infringement or inaccurate observance of any clause in this documentation voids the warranty.
  • The installer must understand and follow all applicable local, state, and federal regulations and standards for building construction, electrical design, fire, and safety.
  • Check with local authorities for permitting requirements before installing or maintaining PV modules, and become familiar with mechanical and electrical requirements for photovoltaic systems.
  • In-nuqqas li ssegwi l-istruzzjonijiet f'din il-gwida jista' jagħmel ħsara lill-komponenti tas-sistema, jipperikola l-persunal, jagħmel ħsara lill-proprjetà, jew jinvalida l-garanzija tal-pannelli.
  • Rooftop PV systems should only be installed on dwellings formally analyzed for structural integrity and confirmed to be capable of handling the additional weighted load of PV system components (including PV modules) by a certified building specialist or engineer.

ĦTIĠIET ĠENERALI

  • Jekk jogħġbok aqra din il-gwida kompletament qabel l-installazzjoni.
  • L-għan ta 'dan id-dokument huwa li jipprovdi rekwiżiti minimi u rakkomandazzjonijiet għal installazzjoni sigura u b'suċċess tal-moduli SoliTek PV.
  • Dan id-dokument fih ukoll rekwiżiti meħtieġa biex tinżamm il-konformità tal-modulu PV SoliTek mal-istandards IEC 61215, IEC 61730, UL 61730.
  • Din il-gwida fiha informazzjoni bażika dwar il-moduli fotovoltajċi tas-serje SOLID JSC "SoliTek Cells", l-installazzjoni tagħhom u l-immaniġġjar sikur. L-istruzzjonijiet kollha għandhom jinqraw u jinftiehmu qabel ma tipprova l-installazzjoni. Jekk hemm xi mistoqsijiet, jekk jogħġbok ikkuntattja lin-negozjant tiegħek jew lil JSC "SoliTek Cells" għal aktar informazzjoni.
  • This documentation refers to the PV-modules themselves and is not meant to be a complete installation manual for personnel not specifically trained to PV-modules.
  • It serves as a general but strictly mandatory reference for the Installer.
  • Ksur jew osservanza mhux preċiża ta' kwalunkwe klawżola ta' din id-dokumentazzjoni iħassar il-garanzija.
  • L-installatur għandu jifhem u jsegwi r-regolamenti u l-istandards lokali, statali u federali applikabbli kollha għall-kostruzzjoni tal-bini, disinn elettriku, nar, u sigurtà, u għandu jiċċekkja mal-awtoritajiet lokali biex jiddetermina r-rekwiżiti applikabbli tal-permessi qabel ma jipprova jinstalla jew iżomm moduli PV u għandu issir familjari mar-rekwiżiti mekkaniċi u elettriċi għal sistemi fotovoltajċi.
  • In-nuqqas ta' segwitu tal-istruzzjonijiet f'din il-gwida jista' jagħmel ħsara lill-komponenti tas-sistema, jipperikola l-persunal, jagħmel ħsara lill-proprjetà, jew jinvalida l-garanzija tal-pannelli.
  • Is-sistemi PV fuq il-bjut għandhom jiġu installati biss fuq abitazzjonijiet li ġew analizzati formalment għall-integrità strutturali u kkonfermati li huma kapaċi jimmaniġġjaw it-tagħbija addizzjonali peżata tal-komponenti tas-sistema PV, inklużi l-moduli PV, minn speċjalista jew inġinier tal-bini ċċertifikat.
  • For your safety, do not attempt to work on a rooftop until safety precautions have been identified and taken, including, without limitation fall protection measures, ladders or stairways, and personal protective equipment (PPE).
  • For your safety, do not install or handle PV modules under adverse conditions, including, without limitation strong or gusty winds, and wet or frosted roof surfaces.
  • Il-kostruzzjoni tal-modulu PV ta 'pjanċa ċatta tikkonsisti f'assemblaġġ laminat ta' ċelloli solari inkapsulati f'materjal iżolanti f'żewġ folji tal-ħġieġ.
  • Żomm din id-dokumentazzjoni f'post sigur għal referenza futura.
  • Tippruvax tiżżarma l-modulu, u tneħħi l-ebda pjanċi tal-isem jew komponenti mehmuża! Jekk tagħmel hekk titħassar il-garanzija.

Immaniġġjar u Applikazzjoni

TQANDIL

  • SoliTek PV modules must be transported in the supplied packaging only and kept in the packaging until they are ready to be installed.
  • Protect pallets against movement and exposure to damage during transportation. Secure pallets from falling over.
  • Taqbiżx l-għoli massimu tal-pallets li għandhom jiġu f'munzelli, kif indikat fuq l-ippakkjar tal-pallet.
  • Store pallets in a cool and dry location until the PV modules are ready to be unpackaged.
  • SoliTek PV modules are heavy and should be handled with care. Never use the junction box or cables as a grip.
  • Do not exert mechanical stress on the cables.
  • Never step on PV modules or drop or place heavy objects on them.
  • Be careful when placing PV modules on hard surfaces and secure them from falling.
  • Broken glass can result in personal injury. PV modules with broken glass cannot be repaired and must not be used.
  • Broken or damaged PV modules must be handled carefully and disposed of properly.

APPLIKAZZJONI

Restrizzjonijiet

  • SoliTek PV modules must be mounted on appropriate mounting structures positioned on suitable buildings, the ground, or other structures suitable for PV modules (e.g. carports, building facades or PV trackers).
  • PV modules must not be mounted on moving vehicles of any kind. Modules must not be installed in locations where they could be submerged in water.
  • Do not install modules above 2000 m (6561 ft) altitude above sea level
  • Dawl ikkonċentrat artifiċjalment m'għandux ikun dirett fuq moduli SoliTek PV.

Rakkomandazzjonijiet

  • SoliTek jirrakkomanda li l-moduli PV jiġu mmuntati f'angolu minimu ta 'inklinazzjoni ta' 10 gradi biex jippermetti tindif proprju minnu nnifsu mix-xita.
  • Sfumatura parzjali jew kompluta ta 'modulu jew moduli PV jista' jnaqqas b'mod sinifikanti l-prestazzjoni tas-sistema.
  • SoliTek jirrakkomanda li jiġi minimizzat l-ammont ta 'dell matul is-sena biex jiżdied l-ammont ta' enerġija prodotta mill-moduli PV.
  • Sistema għolja voltages could be induced in the event of an indirect lightning strike, which could cause damage to PV system components.
  • The open area of wire loops should be minimized in order to reduce the risk of lightning-induced voltagŻidiet.
  • Ventilazzjoni tal-modulu aħjar u kejbils ta 'konnessjoni iqsar iżidu l-produzzjoni tal-enerġija elettrika.

Għal moduli bifacial:

  • Huwa rakkomandat li jiżdied l-għoli tal-pannell PV mill-art sabiex aktar dawl ikun jista 'jivvjaġġa taħt il-modulu u mbagħad jirrifletti
  • Il-gwadann bifacial jiżdied b'mod sinifikanti jekk il-moduli huma installati fuq l-abjad (valur għoli ta 'albedo), uċuħ li jirriflettu d-dawl.

Installazzjoni elettrika

SIGURTÀ

  • Il-moduli PV jistgħu jipproduċu kurrent u voltage meta espost għad-dawl ta' kwalunkwe intensità. Il-kurrent elettriku jiżdied b'intensità tad-dawl ogħla. DC voltage ta '50 Volts jew ogħla huwa potenzjalment letali. Li tikkuntattja ċ-ċirkwiti ħajjin ta 'sistema PV li topera taħt id-dawl jista' jirriżulta f'xokk elettriku letali.
  • Iddiżattiva l-moduli PV billi tneħħihom kompletament mid-dawl jew billi tkopri l-wiċċ ta 'quddiem tagħhom b'materjal opak. Rigward ir-regolamenti tas-sigurtà għal tagħmir elettriku ħaj meta taħdem ma 'moduli li huma esposti għal kwalunkwe dawl. Uża għodda iżolati u tilbes dehbijiet metalliċi waqt li taħdem ma 'moduli PV.
  • Sabiex tevita l-ark u xokk elettriku, ma skonnettjax konnessjonijiet elettriċi taħt tagħbija. Konnessjonijiet difettużi jistgħu jirriżultaw ukoll f'ark u xokk elettriku. Żomm il-konnetturi niexfa u nodfa u kun żgur li jkunu f'kondizzjoni xierqa tax-xogħol. Qatt daħħal oġġetti metalliċi fil-konnetturi jew timmodifikahom b'xi mod sabiex tiżgura konnessjoni elettrika.
  • Do not touch or handle PV modules with broken glass unless the PV modules are first disconnected, and you are wearing proper PPE. Avoid handling PV modules when they are wet unless cleaning the PV modules as directed in this manual. Never touch electrical and wet connections without protecting yourself with insulated gloves.
  • The modules are qualified for Class II protection against electrical shock, in accordance with clause 4 of IEC 61730-1:2016, which can be used in systems operating at > 50 V DC or >240 W, where general contact access is anticipated and modules qualified for safety through UL 61730 within this application class are considered to meet the requirements of Safety Class II.
  • L-installazzjoni tas-sistemi fotovoltajċi solari teħtieġ ħiliet u għarfien speċjalizzat. Għandu jitwettaq biss minn persunal kwalifikat u mgħallem b'mod speċjali. L-installatur jassumi r-riskju kollu ta' korriment, inkluż ir-riskju ta' xokk elettriku.
  • Uża biss tagħmir, konnetturi, wajers u ħardwer tal-immuntar iddisinjati speċifikament għall-użu f'sistema fotovoltajka.
  • Before any manipulation at an installed PV plant, switch it off first on the AC-side, and then on the DC side of the inverter or the charge controller.
  • Meta skonnettja wajers konnessi ma 'modulu fotovoltajku li huwa espost għad-dawl, jista' jseħħ ark elettriku. L-arki jistgħu jikkawżaw ħruq, jibdew nirien, jew inkella joħolqu problemi ta' sikurezza (sa xokk elettriku letali).
  • Iċċekkja għal vol li jifdaltage before starting and observe the local safety-relevant regulations for such working conditions.
  • Taħt kundizzjonijiet normali, modulu fotovoltajku jista 'jipproduċi aktar kurrent u/jew voltage (hawn: 30V DC) milli rrappurtat f'kundizzjonijiet tat-test standard.
  • Kuntatt ma' DC voltage ta' 30 V jew aktar huwa potenzjalment perikoluż. Oqgħod attenta meta wajers jew timmaniġġjaw moduli esposti għad-dawl tax-xemx.
  • Ikkonnettja biss moduli bl-istess kurrent tal-ħruġ nominali f'serje. Jekk il-moduli huma konnessi f'serje, il-volum totalitage hija ugwali għas-somma tal-modulu individwali voltages.
  • Qabbad biss moduli jew kombinazzjonijiet ta 'serje ta' moduli bl-istess voltage in parallel. If modules are connected in parallel, the total current is equal to the sum of the individual module or series combination currents.
  • Dejjem uża l-istess tip ta 'modulu f'sistema fotovoltajka partikolari.
  • If the sum of short circuit currents of the parallel-connected modules exceeds the reverse current, string diodes or fuses have to be used in each string of modules connected in parallel. These string diodes or fuses have to be qualified for the maximum expected current and voltage. The fuse rating value is also corresponds to the maximum reverse current that a module can withstand. The reverse current value can be found on the product label, in the product datasheet or in chapter 8 of the installation manual. Observe the instructions and safety precautions for all other components used in the system, including wiring and cables, connectors, DC-breakers, inverters, etc.
  • Uża tagħmir tas-sigurtà xieraq (għodda iżolati, ingwanti dielettriċi, żraben u eċċ.) approvat għall-użu fuq installazzjonijiet elettriċi.

KONFIGURAZZJONI

  • Taħt kundizzjonijiet normali, modulu fotovoltajku x'aktarx jesperjenza kundizzjonijiet li jipproduċu aktar kurrent u/jew voltage than reported at Standard Test Conditions (STC: 1000 W/ m2, AM 1.5, and 250C/770F cell temperature) or Bifacial nominal power index(BNPl front irradiance 1000 W/m2, back irradiance 135 W/m2 AM 1.5, and 25 OC/770F cell temperature). The short-circuit current (ISC) should be multiplied by a factor of 1.25 and the open-circuit voltage (VOC) għandu jiġi mmultiplikat b'fattur sa 1.25 ibbażat fuq l-inqas u l-ogħla temperatura ambjentali rreġistrata għall-post tal-installazzjoni meta jiġi ddeterminat il-komponent voltagklassifikazzjonijiet e, klassifikazzjonijiet tal-kurrent tal-konduttur, daqsijiet tal-fjusijiet, u daqs tal-kontrolli konnessi mal-output PV.
  • Voltages huma addittivi meta l-moduli PV huma konnessi direttament f'serje, u l-kurrenti tal-moduli huma addittivi meta l-moduli PV huma konnessi direttament b'mod parallel. Moduli PV b'karatteristiċi elettriċi differenti m'għandhomx ikunu konnessi direttament f'serje. L-użu ta 'apparat elettroniku adattat ta' partijiet terzi konnessi ma 'moduli PV jista' jippermetti konnessjonijiet elettriċi differenti u għandu jiġi installat skond l-istruzzjonijiet speċifikati tal-manifattur.
  • Il-vol massimutage of serial interconnection of the modules must be less than the maximum certified module’s system voltage. Ukoll, l-input massimu voltage tal-inverter u tal-apparati elettriċi l-oħra fis-sistema għandhom jiġu kkunsidrati. Iċ-ċirkwit miftuħ voltage of the array string needs to be calculated at the lowest expected a mbient temperature forthe location. The maximal system voltage for the module is indicated in the module’s datasheet.
  • Accordingly, for BLACKSTAR, SOLID or MAGNUS series modules, the values of ISC and VOC under STC or BNPI marked on this module should be multiplied by a factor of 1,25 when determining component voltage ratings, conductor current ratings, fuse sizes, and size of controls connected to the PV output. In the USA, referto Section 690-8 of the National Electrical Code (N EC) for an additional multiplying factor of 125 percent (80 percent de-rating) which may be applicable.

APPARAT TA' PROTEZZJONI TA' KURRURŻ EŻEJDA (OCPD)

  • When the potential reverse current of a PV string exceeds the rated SoliTek PV module series fuse rating (values indicated at the module datasheet) an overcurrent protection device (OCPD) must be used.
  • An overcurrent protection device is required for each series string if more than two series are connected in parallel.
  • In this case, it is needed to use one fuse per string rated at 1.25 x Isc or higher (Isc is the PV module’s short circuit current at STC). A PV fuse on each PV string will protect the PV modules and conductors from overcurrent faults and help minimize any safety hazards.
  • The PV fuse will also isolate the faulted PV string so the balance of the PV system can continue to generate electricity.
  • Fjus amp klassifikazzjoni ≥ 1.25 x Isc
  • Agħżel klassifikazzjoni standard ogħla li jmiss fil-katalgu tal-Fjusijiet PV disponibbli.
  • Isc = Kurrent ta' short-circuit ta' modulu wieħed f'Kundizzjonijiet Standard tat-Test (STC).
  • Meta wieħed iqis il-valuri tal-Isc tal-moduli SoliTek, il-valur it-tajjeb tal-Fjusijiet PV li għandhom jintużaw fl-installazzjoni huwa 30 A. SoliTek jirrakkomanda li tuża fjusis PV kemm fil-kondutturi pożittivi kif ukoll negattivi.

CABLE & WIRING

Il-moduli SoliTek PV huma pprovduti b'żewġ kejbils tal-ħruġ standard, reżistenti għad-dawl tax-xemx li huma mitmuma b'konnetturi PV lesti għall-biċċa l-kbira tal-installazzjonijiet. It-terminal pożittiv (+) għandu konnettur maskili filwaqt li t-terminal negattiv (-) għandu konnettur femminili. Il-wiring tal-modulu huwa maħsub għal konnessjonijiet ta 'serje (jiġifieri, interkonnessjonijiet maskili (+) għal femminili (-)) iżda jistgħu jintużaw ukoll biex jgħaqqdu apparati elettriċi xierqa ta' partijiet terzi li jista 'jkollhom konfigurazzjonijiet ta' wajers alternattivi sakemm jiġu segwiti l-istruzzjonijiet tal-manifattur.
Uża wajers fuq il-post b'żoni ta 'sezzjoni trasversali xierqa li huma approvati għall-użu fil-kurrent massimu ta' short-circuit tal-modulu PV. Il-wajers kollha għandhom ikunu insulati doppji, kejbils cross-linked b'rata minima ta' 1,8 kV (aktar minn 1500 V voltage) u temperatura nominali minima ta' 90 °C (190 °F). Daqs tal-wajer mhux inqas minn 4 mm² (12 AWG). It-tip ta 'insulazzjoni għandu jkun xieraq għat-tip ta' metodu ta 'installazzjoni użat u għandu jissodisfa r-rekwiżiti IEC 61730 u Klassi ta' Sigurtà II.

  • Livell ta' insulazzjoni: 1,8 kV (konduttur-konduttur).
  • Temperatura: -40 °C sa +90 °C (-40 °F sa 190 °F) mill-inqas.
  • Kostruzzjoni tal-konduttur: wajer tar-ram stranded fil-laned b'purità tar-ram akbar minn 99,9%.
  • Insulazzjoni primarja: polyethylene cross-linked (XLPE), reżistenti għad-dawl tax-xemx u għall-umdità, ritardant tal-fjammi. Adattat għal kondjuwit u raceways installati taħt l-art.
  • Insulazzjoni (ġakketta): termoplastiku, reżistenti għad-dawl tax-xemx, ritardant tal-fjammi, reżistenti għall-ilma.
  • Dijametru minimu ta 'barra tal-kejbil b'insulazzjoni - 5,2 mm (2,05 pulzier).
  • Sezzjoni trasversali minima tal-konduttur – 4 mm² (12 AWG).

SoliTek jirrakkomanda lill-installaturi jużaw biss kejbils reżistenti għad-dawl tax-xemx kwalifikati għal wajers ta 'kurrent dirett (DC) f'sistemi PV. Il-kejbils għandhom jitwaħħlu mal-istruttura tal-immuntar b'tali mod li tiġi evitata ħsara mekkanika tal-kejbil u/jew il-modulu. Tapplikax stress fuq il-kejbils. Għat-twaħħil, uża mezzi xierqa, bħal irbit tal-kejbil reżistenti għad-dawl tax-xemx u/jew klipps tal-ġestjoni tal-wajer. Filwaqt li l-kejbils huma reżistenti għad-dawl tax-xemx u reżistenti għall-ilma, fejn possibbli, evita l-espożizzjoni diretta għad-dawl tax-xemx u l-immersjoni fl-ilma tal-kejbils.
It-tul standard tal-kejbils mill-kaxxi tal-junction huwa 1,2 m (47,24 pulzier). Huwa maħsub li żewġ pannelli jkunu interkonnessi fis-sistema.

L-ART

  • Module grounding must be done in accordance with the electrical design and construction specifications, procedures, regulations and other special grounding requirements applicable to the installation sites. If grounding is needed, it should be done accordingly:

Framed type modules grounding
Toqob immarkati b'marka ta 'l-ert fuq il-qafas jistgħu jintużaw biss għall-ert. Ttaqqabx toqob ta' l-ert addizzjonali fuq il-qafas tal-modulu.
The grounding conductor or strap may be copper, copper alloy, or any other material acceptable foruse as an electrical conductor in accordance with local electric codes and regulations.
Il-konduttur tal-ert għandu mbagħad jagħmel konnessjoni mal-ert bl-użu ta 'elettrodu tal-ert adattat.
A bolted connection is required; it incorporates:

  • Daqs tal-bolt ta 'M4.
  • Waxer tas-snien taħt ir-ras tal-bolt jew bolt bis-snien għandu jippenetra kisjiet mhux konduttivi bħall-qafas anodizzat.
  • A fasten nut adattat għall-bolt M4.
  • Il-ħardwer kollu għandu jkun ta' metall mhux tal-ħadid, azzar li ma jissaddadx serje 300, jew protett b'mod xieraq kontra l-korrużjoni.
  • It-torque rakkomandat biex tissakkar l-iskorfina hija 2 Nm÷2.2 Nm (1,48÷1,62 ft-lb).
  • Bolt ta 'l-ert għandu jgħaddi mill-elementi ta' konnessjoni kollha.

SoliTek-SOLID-Series-Solar-Modules-FIG-1

  • L-apparati elenkati u identifikati għall-ertjar ta' frejms metalliċi ta' moduli PV huma permessi li jsejsu l-frejms metalliċi esposti tal-modulu ma' strutturi ta' immuntar ertjati.
  • In any case the grounding screws or other parts have to be used separately from the mounting parts of the module.
  • Alternate grounding options built through the mounting system are acceptable as long as they have been IEC and UL approved.
  • Grounding resistance of the grounding structure shall be reached according to local regulations, Eurocodes, or other legal normative references.

Frameless type modules grounding

  • Due to that modules are without frame, grounding is not forseen. Other PV plant equipment should be grounded according to the local and national electrical codes.

KONNETTURI

  • Connectors for SoliTek PV panels are Stäubli MC4-Evo 2. Keep connectors dry and clean and ensure that connector caps are hand-tight before connecting the modules.
  • Tippruvax tagħmel konnessjoni elettrika b'konnetturi mxarrbin, maħmuġin, jew difettużi b'xi mod ieħor.
  • Evita l-espożizzjoni għad-dawl tax-xemx u l-immersjoni tal-konnetturi fl-ilma. Evita li l-konnetturi jistrieħu fuq l-art jew fuq il-wiċċ tas-saqaf.
  • Do not disconnect under load. Faulty connections can result in arcs and electrical shock.
  • Iċċekkja li l-konnessjonijiet elettriċi kollha jkunu mwaħħla sew. Kun żgur li l-konnetturi kollha tal-qfil huma kompletament imqabbda u msakkra.

DJODI TAL-BYPASS

The PV module’s junction box contains 3 bypass diodes (one in each part of split junction box; Schottky type) connected in parallel with the PV cell strings. In the case of partial shading (hot-spot effect), the diodes bypass the current generated by the non-shaded cells, therebylimiting module heating and performance losses.
Dajowds tal-bypass mhumiex apparati ta 'protezzjoni ta' kurrent żejjed. Diodes bypass jiddevjaw il-kurrent mill-kordi taċ-ċelluli fil-każ ta 'dell parzjali. Il-karatteristiċi ta 'dawn id-dijodi:

  • Voltage klassifikazzjoni – 50 V.
  • Klassifikazzjoni kurrenti - 25 A.

KLASSJONI TA' NAR

  • Il-moduli SoliTek SOLID Bifacial u Blackstar ġew approvati mit-test tan-nar IEC u kisbu Klassi ta 'Fjammabilità A. It-test tan-nar sar b'inklinazzjoni ta' 127 mm (5 pulzieri) għal kull 300 mm (11,81 pulzier), kif preskritt fil-punt A.2.5 ta 'IEC 61730-2.
  • SoliTek SOLID Bifacial has fire rating of 28 according to UL1703-2 standard. SoliTek Blackstar has fire rating of 29 according to UL1703-2 standard.

Immuntar mekkaniku

  • The mechanical loads described in this manual are the test loads.
  • For calculating the equivalent maximum design loads, a safety factor of 1.5 (Design load×1.5 safety factor=Mechanical test load) needs to be considered in compliance with the requirements of the local laws and regulations.

ĦTIĠIET ĠENERALI

  • Modules can be mounted in landscape or portrait orientation. For the bifacial modules, in order to get notable bifacial gain, the distance between the bottom of the modules and the roof or ground surface shall be at least 0,8 m (31,50 inch).
  • Also, the bifacial gain increases significantly if modules are installed above white, light-reflecting surfaces (under surfaces with high albedo value).
  • If the mounting rails are installed across the module, the bifaciality effect will be lower due to back-side cells shading.
  • Jekk jogħġbok osserva r-regolamenti tas-sigurtà u l-istruzzjonijiet ta 'installazzjoni inklużi mas-sistema ta' immuntar. Jekk meħtieġ, jekk jogħġbok ikkuntattja lill-fornitur direttament għal aktar informazzjoni.
  • The modules must be safely set onto the mounting rail.
  • The whole rail supporting the photovoltaic system must be strong enough to resist potential mechanical pressures caused either by wind or snow, in accordance with local, regional and state safety (and other associated) standards.
  • The mounting system shall be tested and inspected by a third-party testing institution with static mechanical analysis capacity in accordance with local national standards or international standards.
  • Before installing modules on a roof, ensure that the roof construction is suitable.
  • In addition, any roof penetration required to mount the modules must be properly sealed to prevent leaks.
  • Kun żgur li l-binarju tal-immuntar mhux se jiddeforma jew jaffettwa l-moduli meta jespandi bħala riżultat tal-espansjoni termali.
  • The module can appear thermal expansion and cold contraction; thus, the interval between two adjoining modules shall be no lesser than 10 mm (0,39 inch).
  • Tippruvax tħaffer toqob fil-wiċċ tal-ħġieġ u l-frejms tal-moduli peress li dan iħassar il-garanzija.
  • The mounting method must not result in the direct contact of dissimilar metals with the aluminum frame of the modules that will result in galvanic corrosion.

Il-komponenti tal-immuntar għandhom ikunu magħmula minn materjali li jdumu, kontra l-korrużjoni u reżistenti għall-UV (istainless steel u komponenti tal-aluminju anodizzati huma rakkomandati).

IMMONTAR MA' CLAMPS

  • Uża mill-inqas 4 cl laminatamps biex tiffissa moduli fuq il-binarji tal-immuntar. Moduli clamps partijiet tal-metall m'għandhomx jiġu f'kuntatt mal-ħġieġ ta 'quddiem jew ta' wara. Meta tagħżel dan it-tip ta’ clamp-metodu ta 'immuntar, uża mill-inqas erba' clamps fuq kull modulu; żewġ clamps għandhom ikunu mwaħħla fuq kull naħa twila. Skont it-tagħbijiet lokali tar-riħ u tas-silġ, cl addizzjonaliamps jistgħu jkunu meħtieġa biex jiżguraw li l-moduli jistgħu jġorru t-tagħbija.
  • Clamps tightening torque għandu jkun mill-inqas 15 Nm (11,06 ft-lb), iżda mhux akbar minn 20 Nm (14,75 ft-lb). Normalment, 15 Nm (11,06 ft-lb), jintlaħaq meta żewġ aluminju profiles imissu lil xulxin. Meta modulu huwa installat f'orjentazzjoni ritratt fuq is-saqaf immejla li għandu> 45° inklinazzjoni, huwa meħtieġ ganċ addizzjonali fil-qiegħ tal-modulu.

SoliTek-SOLID-Series-Solar-Modules-FIG-2 SoliTek-SOLID-Series-Solar-Modules-FIG-3

SOLID Black, Semi-clear, Satin, Agro Frameless

Bil-binarji trasversali

SoliTek-SOLID-Series-Solar-Modules-FIG-4 SoliTek-SOLID-Series-Solar-Modules-FIG-5SoliTek-SOLID-Series-Solar-Modules-FIG-6

BLACKSTAR, SOLID Black 35(40) mm, SOLID Semi-clear 35(40) mm, SOLID Satin 35(40) mm, SOLID Agro 35(40) mm, Magnus Framed mounting

  • Meta tagħżel dan it-tip ta’ clamp-metodu ta 'immuntar, uża mill-inqas erba' clamps fuq kull modulu; żewġ clamps għandhom ikunu mwaħħla fuq kull naħa tal-modulu. Moduli clamps m'għandux jiġi f'kuntatt mal-ħġieġ ta 'quddiem u m'għandux jiddeforma l-qafas.
  • Kun żgur li tevita effetti shadowing fuq iċ-ċelloli solari mill-modulu clamps.
  • The module frame is not to be modified under any circumstances. Do not to block the drain hole of the frame.
  • It-tul ta' clamp should be at least 30 mm (1,18 inch).
  • Il-clamp għandhom jikkoinċidu l-qafas tal-modulu b'mill-inqas 5 mm (0,2 pulzier), iżda mhux aktar minn 10 mm (0,4 pulzier).

Bil-binarji trasversali

SoliTek-SOLID-Series-Solar-Modules-FIG-7 SoliTek-SOLID-Series-Solar-Modules-FIG-8 SoliTek-SOLID-Series-Solar-Modules-FIG-9

Mingħajr binarji trasversali jew binarji huma perpendikolari mal-qafas tal-ġenb twil

SoliTek-SOLID-Series-Solar-Modules-FIG-10 SoliTek-SOLID-Series-Solar-Modules-FIG-11

B'sistema ta 'inserzjoni

SoliTek-SOLID-Series-Solar-Modules-FIG-12

Immuntar bil-boltijiet

  • Il-modulu għandu jkun imwaħħal u sostnut b'erba' boltijiet tal-istainless steel M8 permezz tat-toqob tal-immuntar indikati fuq il-vireg trasversali. Torque fuq il-clamp bolt has to be in range of 8÷10 Nm (5,9÷7,38 ft-lb). The transversal bars positioning is shown in Figure 3.
  • If additional mounting points are required, depending on the local wind and snow loads, then a mounting solution with clamping hardware għandu jintgħażel.

SoliTek-SOLID-Series-Solar-Modules-FIG-13

  • Mounting with bolts can be done only through dedicated predrilled holes in the frame.
  • It-tħaffir ta 'toqob ġodda huwa pprojbit u jħassar il-garanzija.

SoliTek-SOLID-Series-Solar-Modules-FIG-14 SoliTek-SOLID-Series-Solar-Modules-FIG-15

POŻIZZJONI TAL-KAXXA TAL-JUNCTION

  • Għad-distanza bejn il-kaxxa tal-junction u t-tarf tal-modulu jew dimensjonijiet oħra tal-pożizzjoni u ż-żoni tal-junction box jekk jogħġbok irreferi għall-figuri murija hawn taħt.

SoliTek-SOLID-Series-Solar-Modules-FIG-16

MANUTENZJONI

  • Sabiex tiġi żgurata l-aħjar prestazzjoni tal-modulu, SoliTek jirrakkomanda dan li ġej:
  • Jekk meħtieġ, il-faċċata tal-ħġieġ tal-modulu tista 'titnaddaf bl-ilma u sponża ratba jew drapp.
  • Jista 'jintuża deterġent ħafif u li ma jobrox biex jitneħħew tbajja' aktar iebsa.
  • Iċċekkja l-konnessjonijiet elettriċi u mekkaniċi perjodikament u kun żgur li huma nodfa, sikuri, kompluti u siguri.
  • F'każ ta' problema, ikkonsulta ma' persuna liċenzjata/kwalifikata.

SPEĊIFIKAZZJONIJIET

Parametru \ Mudell BLACKSTAR B.96 SOLID Black (Semi-Clear) B.96 35(40) mm BLACKSTAR Satin B.96 MAGNUS B.108
Kundizzjonijiet tat-test STC STC STC STC
Qawwa nominali 455 W 455 W 445 W 510 W
Dejta Elettrika @STC
Qawwa massima (Pmax), W 455 455 445 510
Voltage fil-Qawwa Massima (Vmpp), V 29,71 29,71 29,40 33,34
Kurrent fil-Qawwa Massima (Impp), A 15,31 15,31 15,14 15,30
Ċirkwit Miftuħ Voltage (Voc), V 34,82 34,82 34,40 39,06
Kurrent ta' Short Circuit (Isc), A 15,97 15,97 15,79 15,95
Data Termali
Firxa tat-Temperatura Operattiva -40oC ÷ 85oC (-40°F ÷ 185°F) -40oC ÷ 85oC (-40°F ÷ 185°F) -40oC ÷ 85oC (-40°F ÷ 185°F) -40oC ÷ 85oC (-40°F ÷ 185°F)
Koeffiċjent tat-Temperatura ta' Pmax -0,362%/°C (°F) -0,362%/°C (°F) -0,362%/°C (°F) -0,362%/°C (°F)
Koeffiċjent tat-Temperatura ta' Voc -0,265%/°C (°F) -0,265%/°C (°F) -0,265%/°C (°F) -0,265%/°C (°F)
Koeffiċjent tat-Temperatura ta 'Isc +0,036% /° C (°F) +0,036% /° C (°F) +0,036% /° C (°F) +0,036% /° C (°F)
Data tad-daqs u l-piż
Tul 1762 mm 1762 mm 1762 mm 1961 mm
Wisa' 1134 mm 1134 mm 1134 mm 1134 mm
Ħxuna 30 mm 35(40) mm 30mm 30 mm
Piż 25,5 kg 35(36) kg 25,5 kg 28,5 kg
Metodu ta 'immuntar
Reference to the chapter 3.3 3.3 3.3 3.3
Oħrajn
Kurrent b'lura massimu, A 30
Fire    class, IEC 61730/UL 61730 A/Tip II
Sistema massima voltage, V 1500

Table 9. Electrical and mechanical parameters table.

Parametru \ Mudell SOLIDU Semi- clear B.96 SOLID Black B.96 SOLIDU Satin B.96 SOLIDU Agro B.64
Kundizzjonijiet tat-test STC STC STC STC
Qawwa nominali 455 W 455 W 445 W 300 W
Dejta Elettrika @STC
Qawwa massima (Pmax), W 455 455 445 300
Voltage fil-Qawwa Massima (Vmpp), V 29,71 29,71 29,40 19,60
Kurrent fil-Qawwa Massima (Impp), A 15,31 15,31 15,14 15,31
Ċirkwit Miftuħ Voltage (Voc), V 34,82 34,82 34,40 22,76
Kurrent ta' Short Circuit (Isc), A 15,97 15,97 15,79 15,97
Data Termali
Firxa tat-Temperatura Operattiva -40oC ÷ 85oC (-40°F ÷ 185°F) -40oC ÷ 85oC (-40°F ÷ 185°F) -40oC ÷ 85oC (-40°F ÷ 185°F) -40oC ÷ 85oC (-40°F ÷ 185°F)
Koeffiċjent tat-Temperatura ta' Pmax -0,30%/°C (°F) -0,30%/°C (°F) -0,30%/°C (°F) -0,30%/°C (°F)
Koeffiċjent tat-Temperatura ta' Voc -0,25%/°C (°F) -0,25%/°C (°F) -0,25%/°C (°F) -0,25%/°C (°F)
Koeffiċjent tat-Temperatura ta 'Isc +0,045% /° C (°F) +0,045% /° C (°F) +0,045% /° C (°F) +0,045% /° C (°F)
Data tad-daqs u l-piż
Tul 1772 ± 2 mm 1772 ± 2 mm 1772 ± 2 mm 1772 ± 2 mm
Wisa' 1144±2 1144±2 1144 ± 2 mm 1144 ± 2 mm
Ħxuna 7,2 mm 7,2 mm 7,2 mm 7,2 mm
Piż 33kg 33 kg 33 kg 33 kg
Metodu ta 'immuntar
Reference to the chapter 3.2 3.2 3.2 3.2
Oħrajn
Kurrent b'lura massimu, A 30
Fire    class, IEC 61730/UL 61730 A/Tip II
Sistema massima voltage, V 1500

Table 10. Electrical and mechanical parameters table.

Parametru \ Mudell SOLID Satin B.96 35 mm SOLID Satin B. 96 40 mm SOLID AgroB.64 35 mm SOLID AgroB.64 40 mm
Kundizzjonijiet tat-test STC STC STC STC
Qawwa nominali 445 W 445 W 300 W 300 W
Dejta Elettrika @STC
Qawwa massima (Pmax), W 445 445 300 300
Voltage fil-Qawwa Massima (Vmpp), V 29,40 29,40 19,60 19,60
Kurrent fil-Qawwa Massima (Impp), A 15,14 15,14 15,31 15,31
Ċirkwit Miftuħ Voltage (Voc), V 34,40 34,40 22,78 22,78
Kurrent ta' Short Circuit (Isc), A 15,79 15,79 15,97 15,97
Data Termali
Firxa tat-Temperatura Operattiva -40oC ÷ 85oC (-40°F ÷ 185°F) -40oC ÷ 85oC (-40°F ÷ 185°F) -40oC ÷ 85oC (-40°F ÷ 185°F) -40oC ÷ 85oC (-40°F ÷ 185°F)
Koeffiċjent tat-Temperatura ta' Pmax -0,362%/°C (°F) -0,362%/°C (°F) -0,30%/°C (°F) -0,30%/°C (°F)
Koeffiċjent tat-Temperatura ta' Voc -0,265%/°C (°F) -0,265%/°C (°F) -0,25%/°C (°F) -0,25%/°C (°F)
Koeffiċjent tat-Temperatura ta 'Isc +0,036% /° C (°F) +0,036% /° C (°F) +0,045% /° C (°F) +0,045% /° C (°F)
Data tad-daqs u l-piż
Tul 1762mm 1762mm 1762 mm 1762 mm
Wisa' 1134 mm 1134 mm 1134 mm 1134 mm
Ħxuna 35 mm 40 mm 35 mm 40 mm
Piż 35 kg 36kg 35 kg 36 kg
Metodu ta 'immuntar
Reference to the chapter 3.3
Oħrajn
Kurrent b'lura massimu, A 30
Fire    class, IEC 61730/UL 61730 A/Tip II
Sistema massima voltage, V 1500

Table 11.Electrical and mechanical parameters table.

  • The electrical characteristics are within of the indicated values of ISC (φISC) ±3%, VOC (ϕVOC) ±3,5% and PMPP (ϕPmax) ±5%, under Standard Test Conditions (STC) (irradiance of 1000 W/m²,AM 1.5 spectrum, and a cell temperature of 25°C / 77°F)
  • Il-pannelli kollha SoliTek SOLID PV jikkorrispondu għall-klassi tas-sigurtà elettrika II.

Ċaħda ta' responsabbiltà

  • Peress li huwa impossibbli għal SoliTek li jikkontrolla l-installazzjoni, it-tħaddim, l-applikazzjoni u l-manutenzjoni tas-sistema fotovoltajka skont din l-istruzzjoni. SoliTek ma jaċċettax ir-responsabbiltà u espressament jiċħad ir-responsabbiltà għal kwalunkwe telf, ħsara jew spiża li tirriżulta minn jew b'xi mod konness ma' tali installazzjoni, tħaddim, użu jew manutenzjoni.
  • SoliTek will not take any responsibility for any possible violation of patent rights and third-party rights that are related to the application of the solar energy system. No permission of patents is given through implication.
  • The information of this instruction is from the knowledge and experiences of SoliTek. However, the instructions and suggestions of this instruction do not make an external or internal of guarantee. SoliTek reserves the right to revise this instruction, products and all the information about products without prior notification to customers.

www.solitek.eu

FAQ

  • Q: What should I do before installing the PV modules?
    • A: Read this entire guide, understand all instructions, and ensure compliance with all local, state, and federal regulations. Consult a certified building specialist for the structural integrity of the dwelling.
  • Q: Can I install the PV modules myself without professional training?
    • A: This documentation is not a complete installation manual for personnel not specifically trained in PV-modules. It serves as a general but strictly mandatory reference for the installer. Professional installation is highly recommended.
  • Q: What happens if I don’t follow the instructions in this guide?
    • A: Failure to follow instructions may damage system components, endanger personnel, damage property, or invalidate the panel warranty.
  • Q: Is it safe to work on a rooftop during installation?
    • A: Do not attempt to work on a rooftop until safety precautions have been identified and taken, including fall protection measures, ladders or stairways, and personal protective equipment (PPE). Avoid adverse conditions like strong winds or wet/frosted roofs.
  • Q: How should I store the PV modules before installation?
    • A: Store pallets in a cool and dry location until the PV modules are ready to be unpackaged. Do not exceed the maximum stacking height indicated on the packaging.

Dokumenti / Riżorsi

PDF thumbnailSOLID Series Solar Modules
Installation Guide · SOLID Series Solar Modules, SOLID Series, Solar Modules, Modules

Referenzi

Staqsi Mistoqsija

Use this section to ask about setup, compatibility, troubleshooting, or anything missing from this manual.

Staqsi Mistoqsija

Ask about setup, compatibility, troubleshooting, or anything missing from this manual. Name and email are optional.