ENTTEC 73539 DIN PIXIE
Informazzjoni dwar il-Prodott
Speċifikazzjonijiet:
- Gwida tal-Ħolqien tal-Protokoll tad-Dwana
- Compatible with ENTTEC pixel controllers: DIN PIXIE, PIXELATOR MINI, PIXELATOR MINI MK2, OCTO MK2, OCTO MK3
- Firmware Version Requirements: V1.0 or above for some models, V2.0 or above for others, V4.0 or above for OCTO MK2
Istruzzjonijiet għall-Użu tal-Prodott
Introduzzjoni:
ENTTEC Pixel controllers support over 20 default pixel protocols. The custom protocol feature allows users to create a custom protocol for pixel fixtures not covered by default protocols without the need for new firmware.
Rekwiżiti ta' Setup:
- Datasheet of the desired pixel fixture
- Computer to access the device settings page
- For ENTTEC Ethernet Controller: Device IP address (DHCP or static)
- For DIN PIXIE: EMU Software for configuration
Guide to Custom Protocol Creation:
- Verify datasheet for compatible pixel protocol
- Navigate to the Device’s User Interface to enablethe custom protocol feature
- Adjustthe pixel fixture’s data voltage timing viathe web interface based othe n datasheet
Step 1: Verify Datasheet for Compatible Protocol
- Check the data transmission method from the datasheet
- Identify data transmission method (e.g., D1-D2-D3…Dn or C1-C2-D1-D2…Dn)
- Choose a supported protocol with a similar data transmission method
FIRMWARE KOMPATIBBLI
Il-ħolqien ta' protokoll personalizzat jidher fil-kontrolluri tal-pixel ENTTEC li ġejjin:
| SKU | Prodott | Verżjoni tal-Firmware |
| 73539 | DIN PIXIE | V2.0 jew aktar |
| 70067 | PIXELATOR MINI | V2.0 jew aktar |
| 70068 | PIXELATOR MINI MK2 | V1.0 jew aktar |
| 71521 | OCTO MK2 | V4.0 jew aktar |
| 71522 | OCTO MK3 | V1.0 jew aktar |
INTRODUZZJONI
- ENTTEC Pixel controllers support more than 20 pixel protocols by default. In the event of missing protocol, this custom feature allows users to create a custom protocol for the desired pixel fixture anytime without having to submit a support request for new firmware.
- Din il-karatteristika tippermetti lill-utenti jaġġustaw il-voltage timing ibbażat fuq il-protokolli appoġġjati jekk il-metodu ta 'trażmissjoni tad-dejta jaqbel ma' kwalunkwe protokolli appoġġjati tagħna.
- Dan id-dokument jipprovdi struzzjonijiet ta 'setup għall-ħolqien ta' protokoll tal-pixels personalizzat u l-verifika tal-kriterji.
REKWIŻITI TA' SETUP
Dawn li ġejjin huma meħtieġa biex jinħoloq protokoll tad-dwana:
- Datasheet: Obtain the datasheet of the desired pixel fixture to gather necessary information. Contact the dealer or manufacturer for this document.
- Apparat: Use a computer to access the device settings page.
- For the TEC Ethernet Controller: Obtain the device IP address, which can be either DHCP or static, based on your network settings. Discover the IP using the ENTTEC EMU app.
- For DIN PIXIE: Use the EMU Software for configuration.
GWIDA GĦALL-ĦOLQIEN TA’ PROTOKOLL DWANA
Din il-karatteristika tippermetti lill-utenti jaġġustaw id-data voltage timing to meet specific protocol needs. To create a custom protocol:
- Ivverifika d-datasheet għall-protokoll tal-pixel kompatibbli.
- Innaviga lejn l-Interface tal-Utent tal-Apparat biex tippermetti l-karatteristika tal-protokoll tad-dwana.
- Aġġusta l-volum tad-dejta tal-apparat tal-pixeltage timing permezz tal- web interface skont id-datasheet tal-manifattur.
Pass 1: Ivverifika d-datasheet għall-protokoll kompatibbli
- Ivverifika l-metodu tat-trażmissjoni tad-dejta tal-protokoll mixtieq tiegħek mid-datasheet.
- The data transmission method implies how the data is forwarded. Below are demonstrated the common data transmission methods:
- L-aktar metodu komuni jittrasmetti data mingħajr bits addizzjonali (eż., D1-D2-D3...Dn).
Example: Informazzjoni maqbuda mid-datasheet tal-WB2812B
- Xi protokolli, bħal TM1814, jinkludu data addizzjonali fuq quddiem (eż., C1-C2-D1-D2...Dn).
Example: Informazzjoni maqbuda mid-datasheet ta' TM1814
- L-aktar metodu komuni jittrasmetti data mingħajr bits addizzjonali (eż., D1-D2-D3...Dn).
- The data transmission method implies how the data is forwarded. Below are demonstrated the common data transmission methods:
- Innomina l-protokoll ta’ tqabbil appoġġjat mill-apparat (jew agħżel minn hawn fuq example) that shares the same data transmission method as your desired pixel protocol.
- Ipproċedi għall-Pass 2 għal aktar konfigurazzjoni.
Step 2: Navigate to the Device’s Settings page to enable the custom protocol feature
In this step, the OCTO/PIXELATOR MINI Series and Din PIXIE are guided accordingly due to their distinct interfaces.
For ENTTEC Ethernet Controllers (OCTO/PIXELATOR MINI Series)
- Access to the OCTO/PIXELATOR MINI web interface
- Google Chrome huwa ssuġġerit bħala l- web browser to access the OCTO/PIXELATOR MINI’s web interface.
- Free ENTTEC app, EMU can be used to discover OCTO/PIXELATOR MINI’s IP address. See the ENTTEC websit www.enttec.com biex tniżżel l-app.
- After entering the IP address of OCTO/PIXELATOR MINI, the user will land on the Home page of OCTO/PIXELATOR MINI’s User Interface.

Example of the OCTO homepage in Figure 1 indicates IP address 10.10.3.31, which was assigned by the DHCP server. For the out-of-box OCTO/PIXELATOR MINI that is connected directly to a computer (no DHCP server), the default IP address is 192.168.0.10.
See OCTO/PIXELATOR MINI User Manual ‘Networking’ section for more information.
- Navigate to the Settings page – Output Setting.
Mur għall-output fejn l-apparat tal-pixel mixtieq huwa konness miegħu. Agħżel protokoll tal-pixel mil-lista dropdown li jaqsam l-istess metodu ta 'trażmissjoni vverifikat fil-Pass 1.
- Enable Custom protocol (Continue to Step 3)
Ippermetti l-kaxxa tal-immarka 'Custom' biex taċċessa d-data voltage setup tal-ħin. Immarka biex tiddiżattiva l-protokoll tad-dwana.
Għal DIN PIXIE
- Qabbad DIN PIXIE ma' kompjuter billi tuża USB Type-B.
- Tnedija Software EMU.
- Skennja għall-apparat u kklikkja fuq il-Conf tad-DIN PIXIE skoperti.

- Enable Custom Protocol (Continue to Step 3)
Pick a pixel protocol from the dropdown list that shares the same transmission method verified in tp,1, and enable Custom.
Pass 3: Issettja vol personalizzattage timing
- Qabbel il-voltage timing fuq id-datasheet tal-protokoll mixtieq tiegħek. Il-Protokoll tad-dwana jeħtieġ 4 inputs biex tlesti d-dejta voltage aġġustament tal-ħin:
Voltage Timing Definition Bit 0 Ħin Għoli (T0H) Il-voltagĦin għoli meħtieġ għall-kodiċi 0. Bit 1 Ħin Għoli (T1H) Il-voltagĦin għoli meħtieġ għall-kodiċi 1. Overall Bit Time: Il-vol totalitage time for a single bit. Lower limit = T0H+T0L
Upper limit = T1H+T1L
Irrisettja l-Ħin Il-vol totalitagĦin baxx meħtieġ biex terġa 'tiġi reset it-trażmissjoni tad-dejta bejn kull lott tad-dejta. 
- Datasheet – Data voltage timing info Eżample
Mill-folja tad-dejta tal-WB2818B- Locate the ‘Sequence Time’ table in WB2818B’s datasheet for the voltage medda ta' ħin.
- Imla l-voltage medda ta' ħin fil-qasam tad-dwana f'Settings tal-Output.

IMPORTANTI
- ENTTEC recommends taking the median value of the range for the start.
- L-utent ikollu SAVE settings biex il-valur modifikat jidħol fis-seħħ.
- Fine adjustment of value required, followed by actual output test to optimise custom protocol for pixel fixture control.
- ENTTEC recommends a trial run on the actual setup before finalising the custom protocol setup.
- Typical issues of incorrect setup include, including and not limited to, failure to light up and output flickering.
KONKLUŻJONI
- Din il-gwida wriet kif twaqqaf protokoll tad-dwana għal apparati ENTTEC eliġibbli u pprovdiet għarfien tekniku dwar il-verifika tad-datasheet tal-attrezzaturi tal-pixels mixtieqa tiegħek.
- Billi jsegwu dawn il-passi, l-utenti jistgħu joħolqu protokoll tal-pixels personalizzat li ma jinstabx fil-lista drop-down mingħajr ma jistennew appoġġ tekniku jew rilaxx ġdid tal-firmware. Jekk għandek mistoqsijiet jew diffikultà biex issib l-informazzjoni t-tajba, ikkuntattja lit-tim ta’ appoġġ ta’ ħbiberija tagħna fl-uffiċċji lokali.
FAQ
How do I access the device settings page on my computer?
You can access the device settings page by connecting your computer to the device's network and entering the IP address in a web browser.
Can I create a custom protocol without the datasheet?
It is recommended to have the datasheet to ensure accurate customization of the protocol based on the pixel fixture's specifications.
Dokumenti / Riżorsi
![]() |
ENTTEC 73539 DIN PIXIE [pdfManwal tal-Istruzzjonijiet DIN PIXIE, PIXELATOR MINI, PIXELATOR MINI MK2, OCTO MK2, OCTO MK3, 73539 DIN PIXIE, 73539, DIN PIXIE, PIXIE |