The Aninerel ANJ-12KP-SP-WIFI is a 12000W solar hybrid inverter designed for both on-grid and off-grid solar power systems. It converts 48V DC power to 120V single-phase or 240V split-phase AC power, providing a continuous output of 12,000W and a peak output of 24,000W. This inverter features two built-in MPPT solar charging controllers, supporting up to 6,000W + 6,000W PV input with a maximum DC voltage of 500V and a maximum PV charging current of 220A. It is suitable for various applications including RVs, homes, cabins, and workshops.

Aninerel ANJ-12KP-SP-WIFI 12000W Solar Hybrid Inverter

Stampa 1.1: Quddiem view of the Aninerel ANJ-12KP-SP-WIFI 12000W Solar Hybrid Inverter, showing the display screen and indicator lights.

Aninerel Single-Phase Hybrid Inverter System Diagram

Image 1.2: Diagram illustrating a typical single-phase hybrid inverter system setup, showing power flow from solar panels, grid, and battery to household loads.

2. Karatteristiċi ewlenin

Aninerel Hybrid Solar Inverter Features

Immaġni 2.1: Fuqview of key features including battery compatibility, grid connection, scalability, versatile design, flexible settings, and wireless communication.

3. Komponenti tal-Prodott u Aċċessorji

The following items are typically included with your Aninerel ANJ-12KP-SP-WIFI Hybrid Solar Inverter:

Aninerel Hybrid Solar Inverter Product Accessories

Image 3.1: Contents of the product package, including the inverter, manual, installation tools, cables, CTs, and WiFi module.

4. Setup u Installazzjoni

4.1. Installazzjoni Fiżika

Ensure the inverter is mounted in a well-ventilated area, protected from direct sunlight and moisture. The IP65 rating allows for indoor or semi-outdoor use. Refer to the included instruction manual for detailed mounting procedures and clearances.

4.2. Connection Ports Overview

Familiarize yourself with the various connection ports on the inverter. Proper connection is crucial for safe and efficient operation.

Aninerel Hybrid Solar Inverter Connection Ports

Immaġni 4.1: Dettaljata view of the inverter's connection panel, labeling each port for display, pilot lamp, AC output, AC input, WiFi port, USB, communication ports (RS485-1, RS485-2/CAN), dry contact, CT sensing, ON/OFF switch, PV parameters, battery parameters, parallel communication, AC input breaker, and grounding screw hold.

  1. Skrin tal-wiri
  2. Pilota lamp
  3. Port tal-ħruġ tal-AC
  4. Port tad-dħul AC
  5. WiFi port (optional)
  6. Port tal-komunikazzjoni USB
  7. Port tal-komunikazzjoni RS485-1
  8. RS485-2/CAN communication port
  9. Port ta 'kuntatt niexef
  10. CT sensing for self-consumption (optional)
  11. Swiċċ rocker ON/OFF
  12. Photovoltaic (PV) parameters
  13. Parametri tal-batterija
  14. Port tal-komunikazzjoni parallela (modulu parallel biss)
  15. Interruttur tal-input AC
  16. Istiva bil-kamin tal-ert

4.3. Konnessjonijiet elettriċi

All electrical wiring should be performed by a qualified electrician in accordance with local electrical codes and regulations.

Aninerel Hybrid Solar Inverter Wiring Diagram

Image 4.2: Detailed wiring diagram showing connections for PV input, utility/generator input, battery, and inverter output to household loads.

4.4. Konnessjoni Parallel

The inverter supports parallel connection of up to 6 units to increase total power output and surge capacity. This allows for flexible configurations including single-phase, split-phase, or three-phase systems.

Aninerel Hybrid Solar Inverter Versatile Design Parallel Connection

Image 4.3: Diagrams illustrating various parallel connection configurations for single-phase and split-phase systems, showing how multiple inverters can be combined.

Aninerel Hybrid Solar Inverter Max 6 Parallel Connection

Image 4.4: Illustration of maximum 6 parallel connections for 120V single-phase/240V split-phase residential systems, delivering up to 72kW of power.

4.5. WiFi Monitoring Setup

The inverter includes a WiFi module for real-time monitoring of its operating status via a mobile application. Install the WiFi module into the designated port. Download the "Smart Value" app from the Google Play Store or Apple App Store to configure and monitor your system.

Aninerel Hybrid Solar Inverter WiFi Monitoring Setup

Image 4.5: Diagram showing the WiFi module connection to the inverter and a user monitoring the system via a smartphone app. The app "Smart Value" is available on Google Play and the App Store.

For detailed instructions on connecting the WiFi module and setting up the monitoring application, refer to the specific instructions provided with the WiFi module or contact customer support.

5. Istruzzjonijiet Operattivi

5.1. LCD Screen and Indicator LEDs

The inverter features an LCD screen and indicator LEDs to provide real-time status updates. The LCD allows for configuration of various system settings.

Use the control buttons adjacent to the LCD screen to navigate menus and adjust settings such as charging current, voltage thresholds, and operational priority modes.

5.2. Charging Priority Modes

The inverter offers four charging modes to control how the battery bank is charged from different power sources:

Aninerel Hybrid Solar Inverter Charging and Load Priority Settings

Image 5.1: Diagrams illustrating the different charging priority modes (Solar Priority, Solar and AC input, Solar Only) and load priority modes (Solar Priority, AC Priority, DC Priority).

5.3. Output Priority Modes

The inverter provides three output modes to manage how appliances are powered:

5.4. No-Battery Operation

The inverter supports operation without a connected battery bank for direct solar-to-load applications. In this mode, the inverter will directly power loads from solar PV input. Ensure proper configuration for this mode as per the detailed manual.

6. Manutenzjoni

Regular maintenance helps ensure the longevity and optimal performance of your inverter. Always disconnect all power sources before performing any maintenance.

7 Issolvi l-problemi

This section provides general guidance for common issues. For detailed troubleshooting, refer to the complete instruction manual or contact technical support.

ProblemaKawża PossibbliSoluzzjoni
L-inverter mhux qed jixgħelNo DC input from battery/PV; AC input breaker tripped; ON/OFF switch off.Iċċekkja l-konnessjonijiet tal-batterija u voltage; ensure PV input is sufficient; reset AC input breaker; turn ON/OFF switch to ON.
Ebda output ACOverload; battery low; fault condition; output mode setting.Reduce load; check battery charge; check fault codes on LCD; verify output mode settings.
Il-batterija mhix qed tiċċarġjaPV input insufficient; charging mode setting; battery fault.Check solar panel connections and sunlight; verify charging mode (e.g., Solar Only); inspect battery health.
WiFi monitoring not workingWiFi module not installed correctly; network issues; app configuration.Ensure WiFi module is securely connected; check local WiFi network; reconfigure app settings.
Aninerel Hybrid Solar Inverter Built-in Protections

Image 7.1: Diagram illustrating the various built-in protections of the inverter, including overcharge, overload, overcurrent, overvoltage, short circuit, overheat, overspeed, and undervoltagprotezzjoni.

8. Speċifikazzjonijiet

Detailed technical specifications for the Aninerel ANJ-12KP-SP-WIFI Hybrid Solar Inverter.

ParametruValur
MudellANJ-12KP-SP-WIFI
Qawwa tal-Ħruġ RatedSplit phase 12000VA/12000W (Single phase: 7200VA/7200W limited by wiring terminals)
Max. L-Ogħla QawwaSplit phase 18000VA, Single phase 18000VA
Vol Output Ratedtage120Vac (L1/N, L2/N)/240Vac (L1/L2)
Kapaċità tat-Tagħbija tal-Muturi6HP
Frekwenza Klassifikata AC50Hz/60Hz
Kapaċità parallela1~6 units
Ħruġ Voltage Forma tal-mewġMewġa sine pura
Protezzjoni ta 'tagħbija żejda(102%<load<125%) +10% report error, turn off output after 5 minutes; (125%<load<150%) +10% report error, turn off output after 10 seconds; load>150% +10% report error, turn off output after 5 seconds.
Tip ta 'batterijaLithium/Lead-acid batteries
Volum tal-batterija nominalitage51.2V (Vol. tal-bidu minimutage 44V)
Mains/Generator Input Range(90Vac~140Vac) ±2%
Ċertifikazzjoni tas-SigurtàUL STD.1741
Max. Kurrent tal-Iċċarġjar MPPT160A
Max. Mains/Generator Charging Current160A
Max. Hybrid Charge Current220A
Num. ta' MPP Trackers2
Max. Qawwa tal-firxa PV6000W × 2
Max. kurrent tad-dħul22A × 2
Massimu Voltage ta' Ċirkwit Miftuħ500Vdc
MPPT Voltage Firxa90Vdc ~ 500Vdc
Max. Bypass Phase Overload Current2P, 63A/63A (L1/L2)
Effiċjenza tat-Traċċar MPPT95%
Support CommunicationWiFi Modules/RS485/CAN/USB/Dry contact
Dimensjonijiet24.39 x 17.72 x 5.19 pulzieri (61.95 x 45.01 x 13.18 ċm)
Piż62.9 liri (28.53 kg)
Aninerel Hybrid Solar Inverter Detailed Specifications Table

Image 8.1: A table summarizing the detailed technical specifications of the ANJ-12000W-LVP-WIFI model.

9. Appoġġ u Informazzjoni ta 'Kuntatt

For technical assistance, warranty inquiries, or further information, please contact Aninerel customer support.

Aninerel Customer Support Contact Information

Image 9.1: Contact details for Aninerel customer support, including email, phone number, and operating hours.