GEYA GRT6-B2

GEYA GRT6-B2 10A Delay Off Time Relay User Manual

Electronic Type Adjustable Delay Timer 2NO2NC DIN Rail (AC/DC 24V-240V)

1. Prodott Aktarview

The GEYA GRT6-B2 is an electronic delay off time relay designed for industrial and domestic applications. It features adjustable delay settings and is suitable for DIN rail mounting. This manual provides essential information for safe installation, operation, and maintenance.

Karatteristiċi ewlenin:

  • Dewmien Aġġustabbli: Delay can be set directly via panel knobs for convenience and intuitive control.
  • Modi ta' Funzjoni: Supports two primary functions: Delay ON (A) and Delay OFF (B). The GRT6-B2 model features 2SPDT (2NO2NC) contacts.
  • Medda ta' Ħin Wiesgħa: Time scale from 0.1 seconds to 10 days, divided into 10 selectable ranges.
  • Indikazzjoni ta' l-Istatus: Equipped with LED indicators for power (green light) and working status (red light).
  • Disinn kompatt: Ultra-small size, only 18mm width, designed for 35mm DIN rail mounting.
GEYA GRT6-B2 Delay Off Time Relay front view
Figura 1: Quddiem view of the GEYA GRT6-B2 Delay Off Time Relay, showing control knobs and terminals.

2. Informazzjoni dwar is-Sigurtà

Please read this manual carefully before installation and operation. Failure to follow these instructions may result in equipment damage, injury, or death. This device should only be installed and serviced by qualified personnel.

  • Always disconnect power before installing, wiring, or performing maintenance on the device.
  • Kun żgur li l-wajers kollha jikkonformaw mal-kodiċijiet elettriċi lokali u nazzjonali.
  • Tħaddimx l-apparat jekk ikun bil-ħsara jew ma jkunx qed jaħdem sew.
  • Ipproteġi l-apparat mill-umdità, mit-trab, u minn temperaturi estremi.
  • Ivverifika l-vol korretttage and current ratings before connecting to a power source.

3. Product Dimensions and Components

The GRT6-B2 relay is designed for compact installation on a DIN rail. Understanding its dimensions and component layout is crucial for proper integration into your system.

GEYA GRT6-B2 Delay Off Time Relay dimensions
Figure 2: Detailed dimensions of the GRT6-B2 relay in millimeters. The device measures 18mm in width, 95mm in height, and 64mm in depth.
GEYA GRT6-A1 and GRT6-B1 model comparison
Figura 3: Aktarview of different GRT6 models, highlighting common components such as trigger terminal, supply terminal, LED indication, time range selection, time percentage setting, model number, and output contacts.

4. Installazzjoni u Wiring

The GEYA GRT6-B2 relay is designed for easy installation on a 35mm DIN rail. Follow these steps for secure mounting and correct electrical connections.

4.1 Immuntar tal-Ferrovija DIN

The relay snaps onto a standard 35mm DIN rail. Ensure it is securely fastened to prevent movement during operation.

4.2 Wiring Elettriku

Refer to the wiring diagrams below for proper connection of the power supply and load. Always ensure power is disconnected before wiring.

GEYA GRT6-A1/B1 and GRT6-A2/B2 wiring diagrams
Figure 4: Wiring diagrams for GRT6-A1/B1 (1SPDT) and GRT6-A2/B2 (2SPDT) models. Connect L (Line) and N (Neutral) to A1 and A2 respectively for power supply. Output contacts are typically 15, 16, 18 for 1SPDT and 15, 16, 18 and 25, 26, 28 for 2SPDT.

4.3 Power Connection Demonstration

Watch this video for a visual guide on connecting power and load to the GRT6-B1 model, which shares similar wiring principles with the GRT6-B2.

Video 1: Demonstration of power connection and load access for a GEYA GRT6-B1 time relay. This video illustrates the physical wiring process and initial setup.

5. Istruzzjonijiet Operattivi

The GRT6-B2 relay offers adjustable delay functions. Follow these steps to configure and operate your device.

5.1 Function Modes

The GRT6-B2 supports two main function modes:

  • A: Delay ON: The output contacts close after a set delay time once power is applied.
  • B: Delay OFF: The output contacts open after a set delay time once the trigger signal is removed or power is disconnected.
GEYA GRT6-B2 Delay ON and Delay OFF function diagrams
Figure 5: Timing diagrams illustrating the A (Delay ON) and B (Delay OFF) functions. These diagrams show how the output (R) responds to the input voltage (Un) and trigger signal (S) over time.

5.2 L-issettjar tal-ħin

The delay time is set using two rotary knobs on the front panel: one for time range and one for percentage.

GEYA GRT6-B2 How to set time
Figure 6: Instructions on how to set the delay time. First, select the desired time range (e.g., 10m for 10 minutes). Second, adjust the percentage knob (e.g., 50%) to achieve the precise delay (e.g., 5 minutes for 10m range at 50%).

5.3 Indikaturi LED

  • LED aħdar: Jindika l-istatus tal-provvista tal-enerġija.
  • LED aħmar: Indicates the working status of the relay (e.g., timing in progress, output active).

6. Manutenzjoni

The GEYA GRT6-B2 time relay is designed for reliable operation with minimal maintenance. However, periodic checks can help ensure its longevity and proper function.

  • Tindif: Żomm l-apparat nadif u ħieles mit-trab u l-fdalijiet. Uża drapp niexef u artab għat-tindif. Tużax prodotti tat-tindif likwidi.
  • Spezzjoni: Periodically inspect wiring connections to ensure they are secure and free from corrosion. Check for any signs of physical damage or overheating.
  • Ambjent: Kun żgur li l-ambjent operattiv jibqa' fil-firxiet speċifikati tat-temperatura u l-umdità biex tevita ħsara prematura.

7 Issolvi l-problemi

If the GEYA GRT6-B2 relay is not functioning as expected, consider the following common issues:

  • No Power Indication (Green LED Off): Check the power supply connections (A1, A2) and ensure the voltage is within the specified range (AC/DC 24V-240V).
  • Relay Not Activating/Deactivating:
    • Verify the function mode (A or B) is correctly selected.
    • Check the time range and percentage settings.
    • Ensure the trigger signal (S) is correctly applied for Delay OFF functions.
    • Inspect load connections and ensure the load is functioning correctly.
  • Ħin żbaljat: Re-check the time range and percentage settings. Ensure the knobs are firmly set to the desired values.
  • Is-sħana żejda: If the device feels excessively hot, check the load current to ensure it does not exceed the relay's maximum rating (10A/AC1).

If problems persist after checking these points, contact a qualified electrician or the manufacturer for assistance.

8. Speċifikazzjonijiet

Detailed technical specifications for the GEYA GRT6-B2 time relay.

GEYA GRT6-B2 Technical Parameters Table
Figure 7: Comprehensive table of technical parameters for GRT6-A1/B1, GRT6-A2/B2, and GRT6-At/Bt models. This includes function, supply terminals, voltage range, burden, power input, supply voltage tolerance, supply indication, time ranges, time setting, time deviation, repeat accuracy, temperature coefficient, output, current rating, switching voltage, minimum breaking capacity DC, output indication, mechanical life, electrical life (AC1), reset time, operating temperature, storage temperature, and mounting type.
GEYA GRT6-B2 General Specifications
ParametruValur
BrandGEYA
MudellGRT6-B2
FunzjoniDelay ON (A), Delay OFF (B)
Terminali tal-ProvvistaA1-A2
Voltage FirxaAC/DC 24V-240V (50-60Hz)
Input tal-EnerġijaAC max. 6VA/1.9W
Firxiet ta' Ħin0.1s - 10 days (ON, OFF)
L-issettjar tal-ħinPotenzjometru
Output2xSPDT (2NO2NC)
Klassifikazzjoni kurrenti10A/AC1
Qlib Voltage250VAC/24VDC
Temperatura operattiva-20°C sa +55°C (-4°F sa 131°F)
Temperatura tal-Ħażna-35°C sa +75°C (-22°F sa 158°F)
ImmuntarDIN rail EN/IEC 60715
Dimensjonijiet (L x W x H)64mm x 18mm x 95mm (madwar)
PiżAppross. 2.08 uqija

9. Garanzija u Appoġġ

For warranty information, please refer to the documentation provided with your purchase or contact your seller. If you require technical support or have questions regarding the GEYA GRT6-B2 time relay, please reach out to the manufacturer or authorized distributor.

Dokumenti Relatati - GRT6-B2

Preview GEYA GRT6 Series Single-Function Time Relay: Instruction Manual & Technical Specifications
Detailed instruction manual and technical specifications for the GEYA GRT6 Series single-function time relays (GRT6-A, GRT6-B). Covers applications, features, wiring diagrams, and technical parameters.
Preview Relay tal-Ħin GEYA GRT8-EC - Speċifikazzjonijiet Tekniċi u Karatteristiċi
Detailed technical specifications, features, and operational guidance for the GEYA GRT8-EC time relay. This relay is designed for industrial automation, controlling lighting, heating elements, motors, and fans, offering adjustable delay times and DIN rail mounting.
Preview GEYA GRT8-M Multifunction Time Relay - Instruction Manual
Comprehensive instruction manual for the GEYA GRT8-M Multifunction Time Relay, detailing its applications, technical specifications, functions, wiring, and installation.
Preview Manwal tal-Istruzzjonijiet tar-Relay tal-Ħin Multifunzjonali GEYA GRT8-M
Manwal ta' struzzjoni għar-relay tal-ħin multifunzjonali GEYA GRT8-M, li jiddeskrivi l-applikazzjonijiet, il-karatteristiċi, l-ispeċifikazzjonijiet tekniċi, il-funzjonijiet, id-dimensjonijiet u d-dijagrammi tal-wajers tiegħu. Jipprovdi gwida dwar l-installazzjoni u l-issettjar.
Preview GEYA GRLE8-01 Earth Leakage Relay: Instruction Manual & Technical Specifications
Comprehensive instruction manual for the GEYA GRLE8-01 Earth Leakage Relay. Details applications, technical parameters, wiring diagrams, panel layout, testing procedures, dimensions, and ZCT accessory options for electrical safety monitoring.
Preview Manwal tal-Istruzzjonijiet tar-Relay tal-Ħin taċ-Ċikliżmu Asimmetriku GEYA GRT8-S