GAOMON PHO_163

GAOMON 24000 BTU 19 SEER2 Mini Split AC System User Manual

Brand: GAOMON | Model: PHO_163

1. Introduzzjoni

This manual provides detailed instructions for the installation, operation, and maintenance of your GAOMON 24000 BTU 19 SEER2 Mini Split AC System. This high-performance inverter system offers efficient cooling and heating for spaces up to 1500 sq.ft, featuring Wi-Fi connectivity, remote control, and low-noise operation. Please read this manual thoroughly before installation and use to ensure proper function and safety.

GAOMON 24000 BTU Mini Split AC System

Figure 1: GAOMON 24000 BTU Mini Split AC System

2. Informazzjoni dwar is-Sigurtà

WARNING: Professional installation is required for this system. Improper installation can lead to electric shock, fire, or serious injury.

  • Dejjem kun żgur li l-provvista tal-enerġija tkun skonnettjata qabel ma twettaq kwalunkwe installazzjoni jew manutenzjoni.
  • Wear appropriate personal protective equipment (PPE) during installation, including safety glasses, gloves, and a helmet if working at heights.
  • Kun żgur li l-konnessjonijiet elettriċi kollha jikkonformaw mal-kodiċijiet u r-regolamenti lokali.
  • Tippruvax issewwi jew timmodifika l-unità int stess. Ikkuntattja persunal tas-servizz kwalifikat.
  • Żomm it-tfal u l-annimali domestiċi 'l bogħod mill-unità waqt it-tħaddim u l-manutenzjoni.

Vidjo 1: Dan il-vidjo jipprovdi aktar minnview of the installation process for the Mini Split AC Unit, highlighting necessary tools and safety precautions.

3. Kontenut tal-Pakkett

The GAOMON Mini Split AC system is shipped in two packages. Please verify all components are present upon delivery:

  • 1 x Unità ta' Barra
  • 1 x Unità ta' ġewwa
  • 1 x 13 ft Copper Connection Pipe - Air Pipe
  • 1 x 13 ft Copper Connection Pipe - Liquid Pipe
  • 1 x 6.5 ft Drain Hose
  • 1 x 13 ft Communication Wires
  • 1 x Kontroll mill-bogħod
  • 1 x Gwida għall-Utent

Note: Shut-off valves housing and side protection grille are excluded. The air filter is washable and easy to clean.

GAOMON Mini Split AC Package List

Figure 2: Visual representation of the components included in the GAOMON Mini Split AC package.

4. Speċifikazzjonijiet

KaratteristikaValur
Numru tal-MudellPHO_163
Dimensjonijiet tal-Prodott42.87 x 22.44 x 39.37 pulzieri
Piż tal-oġġett82 liri
BrandGAOMON
Fattur tal-FormolaMini-Split
Kapaċità1500 Piedi kubi
Kopertura taż-Żona tal-ArtSa 1500 pied kwadru
Voltage230 Volts
Livell ta' Storbju42 Deċibel
Qawwa tat-tkessiħ24000 Unità Termali Brittanika (BTU)
Proporzjon tal-Effiċjenza Enerġetika Staġjonali (SEER)19
Karatteristiċi SpeċjaliAuto Clean, Heating & Cooling Function, Silent Mode, Sleep Mode, WiFi Enabled
GAOMON Mini Split AC System Dimensions and Specifications

Figure 3: Detailed dimensions and key specifications of the GAOMON Mini Split AC System.

5. Gwida għall-Installazzjoni

Professional installation is strongly recommended for this appliance.

5.1. Preparazzjoni

Għodda u Materjali Meħtieġa

  • Serrieq bit-toqba
  • Multimetru
  • Qtugħ tal-pajpijiet
  • Wrenches hex
  • Refriġerant (R410A)
  • Torque wrench
  • Wrench aġġustabbli
  • Tejp kejl
  • Gauge tal-pressjoni
  • Safety belt (for high installations)
  • Għodda flaring
  • Bracket (for outdoor unit)
  • Livell
  • Tornavit Phillips
  • Elettrosonda
  • Pompa tal-vakwu
  • Tnalji
  • Copper tube (if extending lines)

Environmental Checks

  • Ensure there is no heat source or steam source near the installation area.
  • Avoid obstructions around the inlet and outlet of both indoor and outdoor units.
  • The area should be free from smoke or oil.
  • Do not install in areas with flammable or explosive gas, or corrosive gas.

5.2. Installazzjoni ta 'Unità ta' ġewwa

Agħżel il-Post ta' Installazzjoni

  • The wall for the indoor unit must be hard, flat, and firm to prevent vibration and noise.
  • Maintain a minimum clearance of 15cm to the ceiling.
  • Maintain a minimum clearance of 20cm to obstacles on either side.
  • The unit should be installed between 230-260cm from the floor.

Waħħal il-Pjanċa tal-Immuntar

Place the mounting plate on the wall and use a level to ensure it is horizontal. Select the position for at least 5 screws to firmly fix the plate.

Drill Wall Hole

After determining where the pipe will go through the wall, drill a wall hole. The wall hole should be inclined outward by 5-10 degrees, with a diameter of 60-80mm. Use an anti-dust bag to avoid dust when drilling.

Install Connection Cable

Għaddi l-kejbil tal-enerġija minn wara l-unità ta' ġewwa u waħħalha mal-bord tat-terminal. Waħħal il-kejbil b'ċarruta.amp. Remove the knock-out panel with a knife and remove burrs to prevent the drain pipe from being broken.

Konnessjoni ta 'Pajping Refriġerant

Use both hands to turn the pipe in the desired direction. Aim at the pipe center, tighten the taper nut with fingers, then tighten with two wrenches. Use a torque wrench for precise tightening according to the pipe size (refer to the table in the installation video).

Installa l-Manka tad-Drain

Connect the drain hose with the water outlet pipe, and fix it firmly with adhesive tape. The length should be more than 5cm to prevent water leakage.

Kebbeb il-Piping

Wrap the refrigerant piping, wires, and drain pipe with wrapping tape.

Mount Indoor Unit

Put the refrigerant piping out of the wall hole. Put the indoor unit on the mounting plate. Push the lower part of the indoor unit until a 'click' sound is heard to ensure it is firmly fixed to the wall.

Pipe Protecting Ring and Putty

To protect piping and wires, a pipe protecting ring shall be installed and sealed with putty.

5.3. Installazzjoni ta 'Unità ta' Barra

Agħżel il-Post ta' Installazzjoni

The outdoor unit must be installed in a firm and flat place to prevent vibration and noise.

  • Maintain a minimum clearance of 20cm to the obstruction above.
  • Maintain a minimum clearance of 30cm to obstacles on the left and right sides.
  • Maintain a minimum clearance of 10cm for air intake on the right side.
  • Maintain a minimum clearance of 200cm for air exhaust in front.

Install Outdoor Unit Bracket

If installing the air conditioner in a higher place, the operator should wear a safety belt and helmet. Use a level to ensure the bracket is horizontal and vertical. Use at least 6 expansion bolts to make sure brackets are fixed firmly on the wall.

Waħħal l-Unità ta’ Barra

Poġġi l-unità ta' barra fuq il-parentesi. Uża 4 viti biex tiffissa s-saqajn tal-unità ta' barra.

Qabbad il-pajpijiet tar-refriġerant

Remove the nut from the stop valves. Aim at the pipe center of the stop valve, tighten the taper nut with fingers, then tighten with two wrenches. Screw the 2 caps back on. Use a torque wrench for precise tightening according to the pipe size (refer to the table in the installation video).

Vacuuming

Before vacuuming, check all the nuts of the indoor and outdoor unit are tightened. Connect the stop valve, charging hose, manifold valve, and vacuum pump as shown in the diagram (refer to the installation video). Turn on handle Lo to vacuumize. Vacuumize for at least 15 minutes, making sure the value on the pressure gauge is ≤0.1MPa. Keep pressure for 3-5 minutes after vacuumizing, ensuring pressure springback is ≤0.05MPa. Open the 1/4 liquid valve, and remove the charging hose.

Fix Cables

Neħħi l-għatu tal-kaxxa tal-elettriku. Waħħal il-kejbils mal-bord tat-terminal skont id-dijagramma tal-wajers fuq l-għatu tal-partijiet E. Trid issegwi d-dijagramma tal-wajers ġewwa l-għatu tal-kaxxa. Uża cleamp biex tirranġa l-kejbils. Poġġi lura l-għatu tal-kaxxa tal-elettriku.

Refrigerant Adjustment

When the length of the connecting pipe is changed, an extra amount of refrigerant may need to be added or reduced to ensure optimal operation and performance.

Tul tal-pajp tal-konnessjoniRefriġerant miżjud jew imnaqqasAmmont ta 'refriġerant għall-unità
<3mCC≤12000Btu: tnaqqas 20g/m²≤1Kg
CC≥18000Btu: tnaqqas 50g/m²≤2Kg
3-5mMhux meħtieġ-
5-15mCC≤12000Btu: żid 20g/m²≤1Kg
CC≥18000Btu: żid 30g/m²≤2Kg

Video 2: This video demonstrates the complete installation process for the Mini Split AC Unit, including both indoor and outdoor components.

6. Istruzzjonijiet Operattivi

6.1. Funzjonijiet ta 'Kontroll mill-bogħod

The backlit LCD remote controller allows effortless system control. Key functions include:

  • Modalità Kessaħ: Għal tkessiħ rapidu.
  • Modalità tas-Sħana: For rapid heating.
  • Modalità Niexfa: One-key drying mode to quickly reduce indoor humidity.
  • Fann biss: Low, Mid, High, Turbo 4 wind speeds with 50ft long distance air flow.
  • Modalità Awtomatika: Automatically selects operating mode based on ambient temperature.
  • Wiri mixgħul/mitfi: Controls the unit's display.
  • Modalità Sleep: Adjusts temperature and fan speed for comfortable sleep and quiet operation (41 dB).
  • ECO Energy Saving Mode: Optimizes operation for reduced energy consumption.
  • HEALTH Mode: Activates negative ions, electrostatic dust removal, and PM2.5 removal.
  • Modalità iFEEL: Jissensja t-temperatura fil-post tal-kontroll remot għal kumdità preċiża.
  • Tajmer ta' 24 siegħa: Skeda ħinijiet mixgħul/mitfi.
  • 4D Auto Swing: Jiżgura distribuzzjoni uniformi tal-arja.
GAOMON Mini Split AC Remote Control Functions

Figura 4: Aktarview of the remote control and its various functions.

6.2. Wi-Fi Setup and Smart Control

The unit is Wi-Fi enabled and Google-compatible, allowing control via a smartphone app.

Video 3: This video demonstrates the process of setting up Wi-Fi connectivity for your Mini Split Air Conditioner, enabling smart control via an app.

GAOMON Mini Split AC App Control

Figure 5: The mobile application interface for intelligent control of the AC unit, compatible with Amazon Alexa and Google Assistant.

7. Manutenzjoni

7.1. Tindif tal-Filtru tal-Arja

The air filter is washable and easy to clean. Regular cleaning of the air filter is essential for maintaining optimal performance and air quality. Refer to the full user guide for detailed instructions on how to remove, clean, and reinsert the air filter.

7.2. Funzjoni ta 'Awto-Tindif

The unit features an automatic defrosting and self-cleaning function to maintain internal hygiene and efficiency. This includes a 57°C high-temperature self-cleaning and sterilization process.

GAOMON Mini Split AC Self-Cleaning and Sterilization

Figure 6: Illustration of the 57°C high-temperature self-cleaning and sterilization process.

8 Issolvi l-problemi

If you encounter any issues with your GAOMON Mini Split AC System, please refer to the following common problems and solutions before contacting customer support:

  • L-unità ma tixgħelx: Check power supply, circuit breaker, and ensure the remote control has working batteries.
  • No cooling/heating: Verify the correct mode is selected, check temperature settings, and ensure air filters are clean.
  • Storbju mhux tas-soltu: Check for loose parts, obstructions in the fan, or improper installation of the outdoor unit.
  • Tnixxija tal-ilma: Ensure the drain hose is properly installed and sloped, and not blocked.
  • Remote control missing: If the remote control is missing, contact customer support for a replacement.
  • Problemi ta' konnettività tal-Wi-Fi: Ensure your Wi-Fi network is 2.4GHz, check router settings, and follow the app's troubleshooting steps.

For more complex issues or if the problem persists, please contact GAOMON customer support.

9. Garanzija u Appoġġ

The GAOMON 24000 BTU 19 SEER2 Mini Split AC System comes with a Garanzija tul il-ħajja. For warranty claims, technical support, or any questions regarding your product, please refer to the contact information provided in your purchase documentation or visit the official GAOMON websit.

Dokumenti Relatati - PHO_163

Preview Manwal tal-Utent tat-Tablet Grafika GAOMON WH851 - Konfigurazzjoni, Karatteristiċi, u Soluzzjoni tal-Problemi
Manwal komprensiv għall-utent għat-tablet grafika GAOMON WH851. Tgħallem kif tikkonnettja, tinstalla d-drivers, tuża karatteristiċi bħas-sensittività tal-pressjoni u ċ-ċwievet tas-shortcut, u sib pariri dwar is-soluzzjoni tal-problemi. Ideali għal artisti diġitali.
Preview Manwal tal-Utent tal-Pillola tat-Tpinġija GAOMON M10K 2018
Manwal komprensiv għall-utent għat-tablet tat-tpinġija GAOMON M10K 2018, li jkopri s-setup, il-karatteristiċi, l-installazzjoni tas-sewwieq, u s-soluzzjoni tal-problemi għall-artisti u l-kreaturi.
Preview GAOMON PD1900 Graphics Pen Display Manwal tal-Utent
Manwal tal-utent għall-GAOMON PD1900 Graphics Pen Display, li jkopri s-setup, il-karatteristiċi, l-ispeċifikazzjonijiet, u s-soluzzjoni tal-problemi. Kompatibbli ma' Windows, macOS, u Android.
Preview Manwal tal-Utent tal-GAOMON M1230
Esplora t-tablet tat-tpinġija GAOMON M1230 b'dan il-manwal komprensiv għall-utent. Tgħallem dwar is-setup, il-karatteristiċi, u s-soluzzjoni tal-problemi għall-ħolqien ta' arti diġitali. Kompatibbli ma' Windows, macOS, u Android.
Preview Manwal tal-Utent tal-Gaomon PD1900 Pin Display
Manwal komprensiv għall-utent għall-GAOMON PD1900 Pen Display, li jiddeskrivi l-karatteristiċi, is-setup, l-installazzjoni tas-sewwieq, is-settings, l-ispeċifikazzjonijiet, u l-gwida għas-soluzzjoni tal-problemi.
Preview Gwida għall-Installazzjoni tas-Sewwieq GAOMON għal Windows u Mac
Gwida komprensiva għall-installazzjoni tas-sewwieqa GAOMON kemm fuq is-sistemi operattivi Windows kif ukoll fuq il-Mac, li tiżgura setup xieraq għat-tablets grafiċi GAOMON.