1. Introduzzjoni
The Moxa MGate 5135-1 is a 1-port Modbus TCP Gateway designed for industrial protocol conversion. It facilitates seamless communication between Modbus RTU/ASCII/TCP devices and EtherNet/IP networks. This manual provides essential information for the proper installation, operation, and maintenance of the MGate 5135-1.

Figura 1: Moxa MGate 5135-1 Modbus TCP Gateway. This image shows the device from an angled perspective, highlighting its compact industrial design and various ports and LED indicators on the front panel.
2. Setup u Installazzjoni
2.1 Kontenut tal-Pakkett
Ivverifika li l-pakkett tiegħek fih l-oġġetti li ġejjin:
- Moxa MGate 5135-1 Gateway
- Gwida ta 'Installazzjoni Mgħaġġla
- Karta ta' Garanzija
Jekk xi oġġetti huma nieqsa jew bil-ħsara, ikkuntattja lill-bejjiegħ tiegħek immedjatament.
2.2 Deskrizzjoni tal-Hardware

Figura 2: Front Panel Layout of the MGate 5135-1. This image provides a clear view of the front panel, detailing the location of the Ethernet ports (ETH1, ETH2), LED indicators (POWER1, POWER2, READY, EtherNet/IP, Modbus), and the DB9 serial port (TX/RX).
The MGate 5135-1 features:
- Inputs tal-Enerġija: Dual redundant power inputs (P1, P2) for reliability.
- Portijiet Ethernet: Two 10/100BaseT(X) RJ45 ports (ETH1, ETH2) for network connectivity.
- Port tas-Serje: One DB9 male connector for Modbus RTU/ASCII communication.
- Indikaturi LED: Status LEDs for power, ready status, EtherNet/IP activity, and Modbus activity.
2.3 Immuntar
The MGate 5135-1 is designed for DIN-rail mounting. Ensure a secure fit in an industrial enclosure with adequate ventilation.
2.4 Konnessjoni tal-Enerġija
- Connect a 12-48 VDC power source to the terminal block labeled P1.
- For redundant power, connect a second 12-48 VDC power source to P2.
- Tiżgura polarità xierqa.
2.5 Konnessjoni tan-Netwerk
- Connect an Ethernet cable from your network switch or controller to either ETH1 or ETH2 port.
- The device supports 10/100 Mbps auto-negotiation.
2.6 Konnessjoni tas-Serje
- Connect your Modbus RTU/ASCII device to the DB9 serial port.
- Refer to the device's documentation for pin assignments and wiring configurations (RS-232/422/485).
3. Istruzzjonijiet Operattivi
3.1 Konfigurazzjoni Inizjali
Upon initial power-up, the MGate 5135-1 will attempt to obtain an IP address via DHCP. If DHCP is not available, it will revert to a default IP address (refer to the Quick Installation Guide for the default IP). Access the device's web console via a web browser using its IP address for detailed configuration.
3.2 Modbus to EtherNet/IP Conversion
The primary function of the MGate 5135-1 is to translate Modbus commands and data to EtherNet/IP and vice-versa. This involves:
- Modbus Master/Slave Configuration: Configure the gateway to act as a Modbus master or slave on the serial side, depending on your Modbus device setup.
- EtherNet/IP Adapter Configuration: The gateway functions as an EtherNet/IP adapter, allowing an EtherNet/IP scanner (e.g., PLC) to communicate with Modbus devices.
- Immappjar tad-Data: Map Modbus registers/coils to EtherNet/IP tags or assemblies within the gateway's web interface. This defines how data is exchanged between the two protocols.
Detailed mapping and protocol-specific settings are available in the device's comprehensive user manual, accessible via the Moxa websit.
4. Manutenzjoni
4.1 Kura Ġenerali
- Żomm l-apparat nadif u ħieles mit-trab. Uża drapp artab u niexef għat-tindif.
- Kun żgur li jkun hemm fluss tal-arja adegwat madwar l-unità biex tevita li tissaħħan iżżejjed.
- Avoid exposing the device to extreme temperatures or humidity outside its specified operating range (-10 to 60°C).
4.2 Aġġornamenti tal-Firmware
Iċċekkja l-Moxa perjodikament website for firmware updates. Firmware updates can provide new features, performance improvements, and security enhancements. Follow the instructions provided with the firmware package carefully.
5 Issolvi l-problemi
This section addresses common issues you might encounter with the MGate 5135-1.
5.1 Power LED is Off
- Ivverifika li l-provvista tal-enerġija hija konnessa b'mod korrett u li tipprovdi l-volum speċifikattage (12-48 VDC).
- Iċċekkja l-kejbil tad-dawl għal ħsara.
- Kun żgur li s-sors tal-enerġija huwa attiv.
5.2 Ebda Konnettività man-Netwerk
- Check the Ethernet cable connection to both the gateway and the network switch.
- Verify that the network switch port is active and configured correctly.
- Confirm the gateway's IP address and subnet mask settings.
- Try pinging the gateway's IP address from a connected computer.
5.3 Modbus Communication Failure
- Verify the serial cable connection and pin assignments.
- Check the serial port settings (baud rate, data bits, parity, stop bits) on both the gateway and the Modbus device.
- Ensure the Modbus device address is correctly configured in the gateway's settings.
- Confirm that the Modbus device is powered on and functioning correctly.
5.4 EtherNet/IP Communication Failure
- Verify the EtherNet/IP scanner (e.g., PLC) is correctly configured to communicate with the MGate 5135-1's IP address.
- Check the data mapping configuration within the gateway's web interface to ensure Modbus data is correctly exposed to EtherNet/IP.
- Ensure the EtherNet/IP connection is established and healthy.
6. Speċifikazzjonijiet
| Karatteristika | Deskrizzjoni |
|---|---|
| Mudell | MGate 5135-1 |
| Interface Ethernet | 2 x 10/100BaseT(X) Ports (RJ45 connector) |
| Portijiet Serjali | 1 x DB9 Male (RS-232/422/485 selectable) |
| Protokolli Appoġġjati | Modbus RTU/ASCII/TCP, EtherNet/IP |
| Temperatura operattiva | -10 sa 60°C (14 sa 140°F) |
| Input Voltage | 12-48 VDC (Redundant inputs) |
| Piż tal-oġġett | 2 liri |
| Manifattur | Moxa |
7. Garanzija u Appoġġ
Għal informazzjoni dettaljata dwar il-garanzija, jekk jogħġbok irreferi għall-karta tal-garanzija inkluża mal-prodott tiegħek jew żur is-sit uffiċjali ta' Moxa. website. Technical support resources, including FAQs, downloads, and contact information, are available on the Moxa support portal.
Uffiċjali tal-Moxa Websit: www.moxa.com