AMTAST AMT206

AMTAST 2-in-1 Instant Read Thermometer

Model: AMT206 - User Manual

Introduzzjoni

The AMTAST 2-in-1 Instant Read Thermometer (Model AMT206) is a versatile instrument designed for accurate temperature measurement in various applications, including food processing, preparation, brewing, and laboratory settings. It features both a non-contact infrared sensor for surface temperatures and a foldable thermocouple probe for internal temperatures. This manual provides detailed instructions for proper use and maintenance to ensure optimal performance and longevity of your device.

AMTAST 2-in-1 Instant Read Thermometer

Figure 1: AMTAST 2-in-1 Instant Read Thermometer with its protective case.

Karatteristiċi Ewlenin

  • Disinn 2-in-1: Combines non-contact infrared (IR) for surface temperature and a foldable thermocouple probe for internal temperature.
  • Wide Temperature Ranges:
    • Infrared: -67 to 572°F (-55 to 250°C)
    • Probe: -67 to 626°F (-55 to 330°C)
  • HACCP Check Function: Clearly indicates if food is in a dangerous (4~60°C / 40~140°F) or safe temperature zone.
  • Preċiżjoni Għolja: Infrared Accuracy ±1.8°F (32-149°F), Probe Accuracy ±0.9°F (0.5°C).
  • Emissività aġġustabbli: User-adjustable from 0.10 to 1.00 in 0.01 steps (factory preset to 0.95).
  • Modi ta' Kejl: Includes Minimum, Maximum, and Lock modes for continuous scanning.
  • Wiri Doppju: Shows both IR and probe readings simultaneously.
  • Protezzjoni IP65: Provides protection against dust and low-pressure water jets.
  • Disinn portabbli: Ultra-thin, fits into a shirt pocket, comes with a storage case.
  • Mitfi Awtomatiku: Jikkonserva l-ħajja tal-batterija.

Setup

1. Installazzjoni tal-batterija

The AMTAST AMT206 thermometer requires one Lithium battery for operation. Please note that batteries are not included in the package due to aviation security regulations.

  1. Sib il-kompartiment tal-batterija fuq wara tal-apparat.
  2. Iftaħ l-għatu tal-batterija.
  3. Insert the Lithium battery, ensuring correct polarity (+/-).
  4. Agħlaq l-għatu tal-batterija sew.

2. Initial Power On and Unit Selection

Press any button to power on the device. The default temperature unit is usually Fahrenheit (°F). To switch between Celsius (°C) and Fahrenheit (°F):

  • Bl-apparat mixgħul, agħfas il-buttuna Modalità Agħfas il-buttuna ripetutament sakemm tintwera l-unità mixtieqa.

3. Aġġustament tal-Emissività

Emissivity (ε) is a measure of an object's ability to emit infrared energy. Different materials have different emissivity values. The factory preset is 0.95, which is suitable for most organic materials and painted surfaces. For highly reflective surfaces, you may need to adjust the emissivity for accurate IR readings.

  • Agħfas il- Modalità button until 'ε' appears on the display.
  • Uża l- Skennja or Sonda buttons to adjust the emissivity value from 0.10 to 1.00 in 0.01 steps.
  • Agħfas Modalità mill-ġdid biex tikkonferma u toħroġ.
Lura view of AMTAST thermometer showing battery compartment

Figura 2: Wara view of the thermometer, showing the battery compartment and serial number.

Istruzzjonijiet Operattivi

1. Infrared (IR) Temperature Measurement

The IR function measures the surface temperature of an object without contact.

  1. Ensure the probe is folded into the device.
  2. Ipponta s-sensor infra-aħmar lejn l-oġġett fil-mira.
  3. Agħfas u żomm il- Skennja button. The display will show the real-time surface temperature.
  4. Irrilaxxa l- Skennja button to hold the reading on the display.

Distance-to-Spot Ratio (D:S): The AMT206 has a D:S ratio of 2.5:1. This means that at a distance of 2.5 units, the measurement spot diameter is 1 unit. For example, if you are 2.5 inches away from the target, the measurement area will be 1 inch in diameter. Ensure the target is larger than the spot size for accurate readings.

Close-up of thermometer display showing IR reading and HACCP zones

Figure 3: Close-up of the thermometer display, showing an infrared reading and the HACCP temperature zone indicators.

Close-up of thermometer display showing distance to spot ratio diagram

Figura 4: Dettaljat view of the thermometer display, illustrating the Distance-to-Spot (D:S) ratio for infrared measurements.

2. Probe Temperature Measurement

The foldable probe measures the internal temperature of liquids or semi-solid materials.

  1. Unfold the stainless steel probe from the side of the device.
  2. Insert the probe into the center of the food or liquid you wish to measure. Ensure the probe tip is fully immersed and not touching bones or the bottom of the container.
  3. The display will automatically switch to probe mode and show the internal temperature.
  4. Wait for the reading to stabilize (usually a few seconds).
AMTAST thermometer with probe extended

Figure 5: The AMTAST thermometer with its foldable probe extended, ready for internal temperature measurement.

3. Measurement Modes (Min/Max/Lock)

The thermometer offers various modes to enhance measurement utility:

  • Minimum (MIN) Mode: Displays the lowest temperature recorded during a continuous scan.
  • Maximum (MAX) Mode: Displays the highest temperature recorded during a continuous scan.
  • Modalità Lock: Allows for continuous temperature scanning without holding the scan button.

To cycle through these modes, press the Modalità button after initiating a scan or with the probe extended. The display will indicate the active mode.

4. Iċċekkja HACCP

The HACCP (Hazard Analysis and Critical Control Point) check feature provides a visual indication of food safety zones.

  • The display will show indicators for safe and dangerous temperature zones.
  • A specific indicator will light up to show if the measured temperature falls into the safe zone (below 4°C/40°F or above 60°C/140°F) or the dangerous zone (4~60°C / 40~140°F).

Manutenzjoni

1. Tindif

To ensure hygiene and proper functioning, clean the thermometer regularly.

  • Imsaħ il-parti ta' fuq tat-termometru b'reklamaramp drapp. Tgħaddix l-apparat fl-ilma.
  • For the stainless steel probe, wipe it clean with a mild detergent solution and rinse thoroughly before and after each use, especially when measuring food.
  • Do not use abrasive cleaners or solvents, as they may damage the device.

2. Ħażna

When not in use, store the thermometer properly to protect it from damage.

  • Fold the probe back into its housing.
  • Store the thermometer in its provided protective case.
  • Żomm l-apparat f'post frisk u niexef, 'il bogħod mix-xemx diretta u minn temperaturi estremi.

3. Sostituzzjoni tal-batterija

Replace the battery when the low battery indicator appears on the display or the device fails to power on.

  • Follow the battery installation steps outlined in the Setup section.
  • Armi l-batteriji qodma skont ir-regolamenti lokali.

Issolvi l-problemi

If you encounter issues with your AMTAST AMT206 thermometer, refer to the following common problems and solutions:

ProblemaKawża PossibbliSoluzzjoni
L-apparat ma jixgħelx.Batterija baxxa jew mejta; installazzjoni ħażina tal-batterija.Replace battery; ensure correct polarity.
Inaccurate IR readings.Incorrect emissivity setting; target too small or too far.Adjust emissivity for the material; ensure target is larger than spot size and within D:S ratio.
Inaccurate probe readings.Probe not fully inserted; probe touching bone/container.Ensure probe tip is fully immersed in the center of the material, avoiding contact with hard surfaces.
Display shows "OL" or "LO".It-temperatura hija barra mill-medda li tista' titkejjel.Move to a target within the specified temperature range.
Il-buttuni ma jirrispondux.Problema temporanju tas-softwer; batterija baxxa.Remove and reinsert battery; replace battery.

Speċifikazzjonijiet

KaratteristikaSpeċifikazzjoni
Isem tal-MudellAMT206
Firxa ta 'Temperatura Infrared-67 sa 572 ° F (-55 sa 250 ° C)
Infrared Accuracy (HACCP)±1.8°F (32 to 149°F); otherwise ±1.5% of reading
Firxa tat-Temperatura tas-Sonda-67 sa 626 ° F (-55 sa 330 ° C)
Eżattezza tas-Sonda± 0.9 ° F (0.5 ° C)
Riżoluzzjoni0.1°
Proporzjon tad-Distanza għall-Post (D:S)2.5:1
EmissivitàAdjustable from 0.10 to 1.00 (preset 0.95)
Klassifikazzjoni tal-IPIP65
Sors tal-EnerġijaBattery Powered (Lithium battery, not included)
Ħajja tal-batterijaApprox. 40 hours (IR mode), 100 hours (probe mode)
MaterjalPlastik
Dimensjonijiet6.73 x 2.4 x 2.05 pulzieri
Piż6.38 uqija

Garanzija u Appoġġ

AMTAST products are manufactured to high-quality standards. For any questions, technical assistance, or warranty inquiries regarding your AMT206 thermometer, please contact AMTAST customer support through the official channels provided at the point of purchase or on the AMTAST websit. Jekk jogħġbok żomm il-prova tax-xiri tiegħek għal talbiet ta' garanzija.

Dokumenti Relatati - AMT206

Preview Manwal tal-Prodott tat-Termometru tal-Allarm ta' Ġewwa/Barra AMT-105
Manwal tal-prodott għat-termometru tal-allarm ta' ġewwa/barra AMTAST AMT-105, li jagħti dettalji dwar il-karatteristiċi, l-ispeċifikazzjonijiet, il-passi tal-installazzjoni, u l-gwida operattiva tiegħu.
Preview AMTAST Water Timer: Gwida għall-Installazzjoni, it-Tħaddim, u s-Soluzzjoni tas-Soluzzjonijiet
Gwida komprensiva għall-AMTAST Water Timer, li tkopri l-prodott fuqview, speċifikazzjonijiet, installazzjoni, settings tal-programm ta' tisqija awtomatika, tisqija manwali, dewmien għax-xita, serratura għat-tfal, u mistoqsijiet frekwenti.
Preview Manwal ta' Istruzzjonijiet għat-Tester tal-Ħruxija tal-Wiċċ AMTAST
Manwal ta' struzzjonijiet komprensiv għall-AMTAST Surface Roughness Tester, li jiddeskrivi l-karatteristiċi, l-operat, il-manutenzjoni, is-soluzzjoni tal-problemi, u l-ispeċifikazzjonijiet tekniċi tiegħu għal analiżi preċiża tan-nisġa tal-wiċċ.
Preview Amtast AMT620 Lab pH Meter - Karatteristiċi u Speċifikazzjonijiet
Informazzjoni dettaljata dwar l-Amtast AMT620 Lab pH Meter, inklużi l-karatteristiċi tiegħu bħal kumpensazzjoni awtomatika/manwali tat-temperatura tal-pH, funzjoni GLP, kapaċitajiet ta' ffrankar tad-dejta, u komunikazzjoni RS232. L-ispeċifikazzjonijiet għall-pH, mV, u l-firxiet tat-temperatura u l-preċiżjoni huma pprovduti.