DAIKIN 2MXM18AVJU9 + FTXV12AVJU9 + FTXV12AVJU9

Manwal ta' Istruzzjonijiet tas-Sistema Daikin 18,000 BTU (12K + 12K) 21SEER2 2-Zone Mini Split Air Conditioner b'Pompa tas-Sħana R-32

Models: 2MXM18AVJU9 (Outdoor Unit) + (2) FTXV12AVJU9 (Indoor Units)

Ditta: DAIKIN

1. Introduzzjoni

This manual provides essential information for the safe and efficient installation, operation, and maintenance of your Daikin 18,000 BTU 2-Zone Mini Split Air Conditioner Heat Pump R-32 System. Please read this manual thoroughly before using your new air conditioning unit and retain it for future reference.

Daikin 2-Zone Mini Split System components

Figure 1: Complete Daikin 2-Zone Mini Split System with outdoor condenser, two indoor units, and installation accessories.

2. Informazzjoni Importanti dwar is-Sigurtà

WARNING: Installation and servicing of this equipment must be performed by qualified, experienced technicians. Improper installation or servicing can result in property damage, personal injury, or death. This system uses R-32 refrigerant, which requires specific handling procedures. Always consult local codes and regulations.

  • Kun żgur li l-provvista tal-enerġija hija skonnettjata qabel kwalunkwe installazzjoni jew manutenzjoni.
  • Ilbes tagħmir protettiv personali (PPE) xieraq waqt l-installazzjoni u s-servizz.
  • Tippruvax isewwi jew timmodifika l-unità lilek innifsek. Ikkuntattja tekniku tas-servizz kwalifikat.
  • Żomm it-tfal u l-annimali domestiċi 'l bogħod mill-unità ta' barra waqt it-tħaddim.

3. Kontenut tal-Pakkett

Ivverifika li l-komponenti kollha huma preżenti u bla ħsara mal-wasla:

  • 1x 2MXM-A Series Multi-Split 18,000 BTU Heat Pump Air Conditioner Outdoor Condenser
  • 1x Maxwell Wall Mounting Bracket (for outdoor unit)
  • 2x FTXV Series Indoor Fan Coils with Remote Control
  • 2x Maxwell 15 ft Pre-Flared Installation Kits with Interconnecting Cables (for each indoor unit)

4. Speċifikazzjonijiet Tekniċi

Daikin 2-Zone Mini Split System dimensions and specifications

Figure 2: System dimensions and key specifications for the Daikin 2-Zone Mini Split.

KaratteristikaSpeċifikazzjoni
BrandDAIKIN
Mudell Info2MXM18AVJU9 + FTXV12AVJU9 + FTXV12AVJU9
Effiċjenza (SEER2)21
Kapaċità1.5 Tunnellati (18,000 BTU)
Livell ta' Storbju24 Deċibel (Ġewwa)
RefriġerantR-32
Kapaċità tat-tkessiħ17,200 BTU (5,700 BTU Min – 21,000 BTU Max)
Kapaċità tat-tisħin18,500 BTU (2,900 BTU Min – 25,000 BTU Max)
Operating Cooling Range14°F sa 115°F
Operating Heating Range5°F sa 59.9°F
Provvista tal-Enerġija1Ph, 60 Hz, 208-230V
Ċertifikat AHRI#214837757
Karatteristiċi SpeċjaliInverter Compressor, Multi-Zone Comfort, Automatic Defrosting, Silent Mode, 4 Way Swing, Titanium Photocatalytic Air Purifying Filter, Econo Mode, Remote Controlled, Wireless LAN connection, Self-diagnosis

5. Gwida għall-Installazzjoni

Installation of this Daikin Mini Split system requires specialized knowledge and tools. It is strongly recommended that installation be performed by an HVAC-certified technician to ensure proper function, safety, and warranty validity.

5.1 Passi Ġenerali ta' Installazzjoni (Installazzjoni Professjonali Rakkomandata)

Il-filmat li ġej jipprovdi ħarsa ġenerali lejnview of mini-split installation steps. Please note that specific details may vary for your Daikin model. Always refer to the detailed instructions provided in your physical owner's manual and consult with a certified installer.

Video 1: General Mini Split Installation Guide. This video demonstrates common steps for installing a mini split unit. Specific procedures for your Daikin model may differ. Professional installation is highly recommended.

5.2 Key Installation Components

  • Immuntar tal-Unità ta' ġewwa: Securely attach the indoor unit mounting plate to the wall using appropriate fasteners. Ensure it is level.
  • Tqegħid tal-Unità ta' Barra: Position the outdoor condenser on a stable, level surface or a dedicated wall mounting bracket. Ensure adequate clearance for airflow.
  • Konnessjoni tas-Sett tal-Linja: Connect the pre-flared copper line sets between the indoor and outdoor units. Ensure all connections are tight and leak-free.
  • Wiring Elettriku: Connect the electrical wiring according to the wiring diagram in your manual. This typically involves connecting power, ground, and communication wires.
  • Vacuuming the Line Set: A vacuum pump must be used to remove all air and moisture from the refrigerant lines before releasing refrigerant. This is a critical step for system performance and longevity.
  • Rilaxx tar-Refriġerant: Carefully open the service valves on the outdoor unit to release the R-32 refrigerant into the system.
Daikin Outdoor Condenser with Blue Fin Anti-Corrosion Treatment

Figure 3: The Daikin outdoor condenser unit features Blue Fin anti-corrosion treatment on the heat exchanger for enhanced durability.

6. Istruzzjonijiet Operattivi

Your Daikin Mini Split system offers versatile control options for personalized comfort.

6.1 Funzjonijiet ta' Kontroll mill-bogħod

Each indoor unit comes with a dedicated remote control. The remote allows you to:

  • Ixgħel/itfi l-unità
  • Aġġusta l-issettjar tat-temperatura
  • Select operating modes (Auto, Cool, Dry, Heat, Fan Only)
  • Aġġusta l-veloċità tal-fann
  • Control airflow direction (Swing)
  • Set timers for automatic operation
  • Activate special features like ECONO mode, Powerful mode, and Sleep mode

Video 2: Demonstrating the remote control and indoor unit operation. This video shows how to use the remote control to adjust settings and highlights the quiet operation of the indoor unit.

6.2 Daikin One Home App & Voice Control

The system works exclusively with the Daikin One Home app, allowing for convenient remote control and monitoring. It also supports voice commands with Alexa and Google Home for effortless environment control.

  • Download the Daikin One Home app from your device's app store.
  • Follow the in-app instructions to connect your mini split system.
  • Integrate with Alexa or Google Home through their respective apps for voice control.
Daikin Indoor Unit Diagram with Features

Figure 4: Diagram of the FTXV Series indoor unit, highlighting key components and features such as washable air filters and Titanium Apatite Deodorizing Filters.

7. Manutenzjoni

Manutenzjoni regolari tiżgura prestazzjoni ottimali u lonġevità tas-sistema Daikin Mini Split tiegħek.

7.1 Tindif tal-Filtru tal-Arja

The indoor units are equipped with 2-Washable Air Filters and 2-Titanium Apatite Deodorizing Filters. Clean these filters regularly (e.g., every 2 weeks or as needed) to maintain air quality and system efficiency.

  • Itfi l-unità u skonnettja l-enerġija.
  • Iftaħ il-pannell ta 'quddiem tal-unità ta' ġewwa.
  • Neħħi l-filtri tal-arja.
  • Clean the washable filters with a vacuum cleaner or wash them with water and a mild detergent. Allow them to dry completely before reinstallation.
  • The Titanium Apatite Deodorizing Filters should be cleaned by vacuuming. Do not wash these filters with water.
  • Erġa' installa l-filtri u agħlaq il-pannell ta' quddiem.

7.2 Manutenzjoni tal-Unità ta' Barra

Keep the area around the outdoor unit clear of debris, leaves, and other obstructions to ensure proper airflow. Periodically clean the outdoor coil with a soft brush or vacuum cleaner. Ensure the drain pan and drain line are clear.

8 Issolvi l-problemi

If you encounter issues with your Daikin Mini Split system, refer to the following common troubleshooting tips. For complex problems, contact a certified HVAC technician.

  • Unità ma Tixgħel: Iċċekkja l-provvista tal-enerġija, is-circuit breaker, u kun żgur li l-batteriji tal-kontroll remot jaħdmu.
  • Tkessiħ/Tisħin Insuffiċjenti: Verify temperature settings, ensure air filters are clean, check for obstructions around indoor/outdoor units, and confirm all windows/doors are closed.
  • Ħsejjes mhux tas-soltu: Minor noises during operation are normal. If loud or unusual noises occur, contact a technician.
  • Tnixxijiet tal-Ilma: Check the indoor unit's drain line for blockages. Ensure the outdoor unit is level.
  • Kodiċi ta' Żball: If an error code appears on the display, consult your detailed owner's manual for specific code meanings and recommended actions.

9. Garanzija u Appoġġ

Your Daikin Mini Split system comes with a Garanzija tal-Manifattur ta' 12 Snin. To ensure warranty validity, the system must be installed by an HVAC-certified technician.

For warranty claims, technical support, or service inquiries, please refer to the contact information provided in your official warranty documentation or visit the Daikin websit.

Dokumenti Relatati - 2MXM18AVJU9 + FTXV12AVJU9 + FTXV12AVJU9

Preview Daikin Multi-Split Type Air Conditioners Engineering Data - 2/3/4MXM-A, 2MXT-A, 2MXTH-A Series
Comprehensive engineering data, installation, and operation manual for Daikin's 2/3/4MXM-A, 2MXT-A, and 2MXTH-A Series Multi-Split Type Air Conditioners and Heat Pumps. Includes technical specifications, wiring diagrams, and installation procedures.
Preview Daikin MXM-A, MXT-A, MXTH-A Series: Engineering Data and Installation Manual
Comprehensive engineering data, specifications, and installation guide for Daikin's MXM-A, MXT-A, and MXTH-A series multi-split type heat pump air conditioning systems.
Preview Daikin Multi-Split Air Conditioner Engineering Data: 2/3/4MXM-A, 2MXT-A, 2MXTH-A Series
Explore detailed engineering data, specifications, and installation guidelines for Daikin's Multi-Split Type Air Conditioners and Heat Pumps, covering the 2/3/4MXM-A, 2MXT-A, and 2MXTH-A series.
Preview Daikin Multi-Split Type Air Conditioners - Heat Pump - Engineering Data for 2/3/4MXM-A, 2MXT-A, 2MXTH-A Series
Detailed engineering data, specifications, and installation guidelines for Daikin's Multi-Split Type Air Conditioners and Heat Pumps, Series 2/3/4MXM-A, 2MXT-A, and 2MXTH-A. Includes technical details on indoor and outdoor units, wiring, piping, and operation limits.
Preview Daikin DH9VS FIT AURORA R-32 Split System Heat Pump - Specifications and Performance Data
Detailed specifications, performance data, and features for the Daikin DH9VS FIT AURORA R-32 Split System Heat Pump, including cooling and heating capacities, sound data, and dimensions.
Preview DAIKIN DX11TA Commercial Split System Air Conditioner Specifications and Data
Explore the detailed specifications, performance data, dimensions, and wiring diagrams for the DAIKIN DX11TA Commercial Split System Air Conditioner series. Designed for robust performance, these units are three-phase, available in 7½ and 10-ton capacities, and utilize R-410A refrigerant. Find technical information for models DX11TA0903A, DX11TA0904A, DX11TA1203A, and DX11TA1204A.