1. Introduzzjoni
This manual provides essential information for the safe and efficient installation, operation, and maintenance of your Ledvance LED Floodlight with Motion and Light Sensor. Please read these instructions carefully before installation and retain them for future reference.
The Ledvance LED Floodlight is a high-performance outdoor lighting solution featuring 41W power, 6000 lumens brightness, a 100-degree beam angle, and a cool white (4000K) light output. It is designed for outdoor use with an IP65 rating, ensuring protection against dust and water jets. Integrated motion and light sensors provide automated control for enhanced energy efficiency and security.

Image 1: Ledvance LED Floodlight with integrated motion and light sensor.
2. Istruzzjonijiet tas-Sigurtà
- Sigurtà Elettrika: Installation must be performed by a qualified electrician in accordance with all local and national electrical codes. Ensure the power supply is disconnected before installation, maintenance, or repair.
- Voltage: Ivverifika li l-provvista voltage matches the requirements specified on the product label (220-240V AC, 50/60Hz).
- L-ertjar: Il-floodlight għandu jkun ertjat kif suppost biex jipprevjeni xokk elettriku.
- Klassifikazzjoni IP65: This product is rated IP65, meaning it is protected against dust ingress and low-pressure water jets from any direction. It is suitable for outdoor use but should not be submerged in water.
- Temperatura: Do not operate the floodlight outside its specified operating temperature range.
- Sħana: The floodlight surface may become hot during operation. Avoid direct contact.
- Sors tad-Dawl: Do not stare directly into the LED light source when it is illuminated, as this may cause eye damage.
3. Kontenut tal-Pakkett
Carefully unpack the box and ensure all components are present and undamaged. The package should contain:
- Ledvance LED Floodlight with integrated motion sensor and light sensor
- Parentesi ta 'montatura
- Installation screws and wall plugs (may vary by region)
- Manwal ta 'Istruzzjoni (dan id-dokument)
4. Installazzjoni
4.1 Post tal-Immuntar
Choose a suitable mounting location that provides the desired illumination area and allows for optimal sensor performance. The floodlight can be surface-mounted on a wall, floor, or ceiling. Consider the following:
- Kun żgur li l-wiċċ tal-immuntar huwa b'saħħtu biżżejjed biex isostni l-piż tal-floodlight.
- Avoid mounting near heat sources or reflective surfaces that could interfere with the motion sensor.
- For optimal motion detection, mount the floodlight at a height of 1.8 to 2.5 meters.
4.2 Passi tal-Immuntar
- Skonnettja l-Enerġija: Qabel tibda, kun żgur li l-provvista ewlenija tal-enerġija għaż-żona tal-installazzjoni tkun mitfija mis-circuit breaker.
- Immarka l-Punti tat-Tħaffir: Use the mounting bracket as a template to mark the drilling points on the chosen surface.
- Drill toqob: Drill holes of appropriate size for the wall plugs. Insert the wall plugs.
- Waħħal il-Bracket: Waħħal il-bracket tal-immuntar mal-wiċċ billi tuża l-viti pprovduti.
- Konnessjoni Elettrika: Connect the mains power cable to the floodlight's terminal block. Ensure correct polarity (Live, Neutral, Earth). Use a suitable waterproof junction box if necessary to maintain the IP65 rating.
- Waħħal il-Floodlight: Secure the floodlight body to the mounting bracket. Adjust the angle of the floodlight and the sensor as desired.
- Irrestawra l-Enerġija: Ladarba l-installazzjoni tkun tlestiet u l-konnessjonijiet kollha jkunu siguri, erġa' daħħal l-enerġija fiċ-ċirkwit.

Image 2: Product dimensions (201mm x 56.5mm x 219mm).
5. Operazzjoni
The Ledvance LED Floodlight operates automatically using its integrated motion and light sensors. There is no manual on/off switch for daily operation. The floodlight will activate based on the sensor settings.
5.1 Aġġustament tas-Sensur
The motion and light sensors can be adjusted to suit your specific needs. Typically, adjustment dials or buttons are located on the sensor unit itself. Refer to the markings on the sensor for specific functions.
- TIME (Delay Time): This dial controls how long the light remains on after motion is detected and no further motion is sensed. Common settings range from a few seconds to several minutes.
- LUX (Sensittività għad-Dawl): This dial determines the ambient light level at which the sensor becomes active. Set it to a low LUX value for the light to activate only in dark conditions, or a higher LUX value for activation even in twilight.
- SENS (Firxa ta' Sensittività/Sejbien): This dial adjusts the sensitivity of the motion sensor, controlling the detection range. A higher sensitivity setting will detect motion over a wider area or at a greater distance.
Adjust these settings carefully to prevent false triggers or insufficient illumination. Test the settings after each adjustment.
6. Manutenzjoni
- Tindif: Skonnettja l-provvista tal-enerġija qabel it-tindif. Uża drapp artab u damp cloth to wipe the floodlight's surface. Do not use abrasive cleaners or solvents, as they may damage the finish or seals.
- Spezzjoni: Periodically inspect the floodlight and its wiring for any signs of damage, wear, or loose connections. Ensure the mounting remains secure.
- Żona tas-Sensor: Keep the sensor lens clean and free from obstructions (e.g., dirt, leaves, spiderwebs) to ensure optimal performance.
- Sors tad-Dawl LED: The LED light source is not user-replaceable. If the LEDs fail, the entire fixture should be replaced by a qualified professional.
7 Issolvi l-problemi
| Problema | Kawża Possibbli | Soluzzjoni |
|---|---|---|
| Id-dawl ma jixgħelx. | No power supply. Incorrect wiring. LUX setting too high (daylight). Sensor obstructed. | Check power supply and circuit breaker. Verify wiring connections. Adjust LUX setting. Clear any obstructions from the sensor. |
| Id-dawl jibqa' mixgħul kontinwament. | Continuous motion detected. TIME setting too long. LUX setting too low (always dark). Wiring fault. | Check for constant motion in the detection zone. Adjust TIME setting. Adjust LUX setting. Inspect wiring for shorts. |
| Light turns on and off frequently. | Intermittent motion. Sensor sensitivity too high. Interference from heat sources or reflections. | Adjust SENS setting. Relocate the floodlight if possible. Remove interfering objects. |
| Is-senser tal-moviment mhux qed jiskopri. | Sensor obstructed. SENS setting too low. Incorrect mounting height/angle. | Clear obstructions. Adjust SENS setting. Re-evaluate mounting position and angle. |
If the problem persists after attempting these solutions, contact a qualified electrician or Ledvance customer support.
8. Speċifikazzjonijiet Tekniċi

Image 3: Product packaging displaying key technical specifications.
| Speċifikazzjoni | Valur |
|---|---|
| Brand | LEDVANCE |
| Numru tal-Mudell tal-Oġġett | 4099854306884 |
| Dimensjonijiet tal-Prodott | 20.1 x 5.7 x 21.9 ċm |
| Materjal | Aluminju |
| Kulur | Abjad |
| Stil | Moderna |
| Temm | Abjad |
| Komponenti Inklużi | Sensor tal-Moviment, Sensor tad-Dawl |
| Użu Speċifiku | Path, Outdoor |
| Lampdell Materjal | Aluminju |
| Direzzjoni tad-Dawl | LED |
| Ibdel l-Istil | Sensor tal-Moviment |
| Tip ta' Installazzjoni | Surface Mounted (Floor or Ceiling Mounting) |
| Batteriji Inklużi? | Nru |
| Lamp Tip | LED |
| Tikketta tal-Enerġija tal-UE | 146 lm/W |
| Fluss Luminuż | 6000 lumens |
| Wattage | 41 Watt |
| Klassifikazzjoni tal-IP | IP65 |
| Klassifikazzjoni IK | IK07 |
| Temperatura tal-Kulur | 4000K (abjad kiesaħ) |
9. Garanzija u Appoġġ
This Ledvance LED Floodlight comes with a Garanzija ta' 5 snin, as indicated on the product packaging. This warranty covers defects in materials and workmanship under normal use and service conditions.
For warranty claims, technical support, or further assistance, please contact Ledvance customer service through their official website or the retailer from whom you purchased the product. Please have your proof of purchase and the product model number (4099854306884) available when contacting support.
For more information, visit the official Ledvance websit: www.ledvance.com





