Introduzzjoni
This manual provides comprehensive instructions for the operation, maintenance, and troubleshooting of the EXTECH SDL600 Sound Meter SD Logger. The SDL600 is a precision instrument designed for environmental sound level measurements and data logging, meeting ANSI and IEC 61672-2013 Class 2 standards.
Please read this manual thoroughly before using the device to ensure proper functionality and accurate readings.
Kontenut tal-Pakkett
Upon unpacking, verify that all items are present and in good condition:
- EXTECH SDL600 Sound Meter
- Karta SD
- Windskrin
- 6 Batteriji AA
- Każ tal-Ġarr iebes
- Manwal ta 'Istruzzjoni (dan id-dokument)
An optional AC Adaptor (UA100-240) may be purchased separately.
Prodott Overview

Figura 1: Quddiem view of the EXTECH SDL600 Sound Meter. The device features a digital display, control buttons, and a microphone with a windscreen.
The SDL600 is designed for accurate sound level measurements. Key components include the microphone (with windscreen), LCD display, and control buttons for various functions such as power, data hold, min/max, and logging.
Setup
1. Installazzjoni tal-batterija
- Sib l-għatu tal-kompartiment tal-batterija fuq wara tal-apparat.
- Open the cover and insert the 6 AA batteries, ensuring correct polarity.
- Ibdel l-għatu tal-kompartiment tal-batterija b'mod sikur.
2. Inserzjoni tal-Kard SD
- Locate the SD card slot, typically on the side or bottom of the device.
- Insert the provided SD card into the slot until it clicks into place.
- Ensure the card is inserted correctly to prevent damage.
3. Windscreen Attachment
Gently slide the foam windscreen over the microphone at the top of the device. The windscreen helps to minimize wind noise during outdoor measurements.
Istruzzjonijiet Operattivi
1. Tixgħil / Mitfi
Agħfas u żomm il- QAWWA buttuna biex tixgħel jew titfi l-apparat.
2. Modi ta 'Kejl
The SDL600 supports both Auto Ranger u Tvarja Manwal. Refer to the on-screen indicators and specific buttons (if available) to switch between these modes for optimal measurement range.
3. Data Hold and Min/Max/Peak Hold
- Agħfas il- ŻOMM buttuna biex tiffriża l-qari attwali fuq id-displej. Agħfas mill-ġdid biex tirrilaxxa.
- Uża l- MIN / MAX button to display the minimum and maximum sound levels recorded during a measurement session.
- Il- ŻOMM IL-QATT function captures and displays the highest instantaneous sound pressure level.
4. Data Logging to SD Card
The SDL600 can log data directly to the inserted SD card in Excel format. This allows for easy transfer to a PC for analysis.
- Issettja SampRata tal-linarda: Is-sampling rate is user-programmable from 1 to 3600 seconds. Access the menu settings (refer to device interface) to configure your desired interval.
- Ibda Logging: Agħfas iddedikat LOG button to begin recording data. The device will record readings with a date and time stamp.
- Waqqaf il-Logging: Agħfas il- LOG buttuna għal darb'oħra biex tieqaf tirrekordja.
- Trasferiment tad-Data: Remove the SD card and insert it into a computer to access the logged data files.
5. Internal Memory Storage
The device's internal memory can store up to 99 readings manually. Consult the device's interface for instructions on how to save and recall these readings.
6. Tifi Awtomatiku
The SDL600 features an Auto Power Off function to conserve battery life. This feature can be disabled through the device's settings menu if continuous operation is required.
Manutenzjoni
1. Tindif
Wipe the device with a soft, dry cloth. Do not use abrasive cleaners or solvents. Ensure the microphone and display are kept clean for accurate readings.
2. Ħażna
When not in use for extended periods, remove the batteries to prevent leakage. Store the device in its hard carrying case in a cool, dry place, away from direct sunlight and extreme temperatures.
3. Kalibrazzjoni
Regular calibration is recommended to maintain measurement accuracy. Refer to professional calibration services or the manufacturer's guidelines for calibration procedures.
Issolvi l-problemi
| Problema | Kawża Possibbli | Soluzzjoni |
|---|---|---|
| L-apparat ma jixgħelx. | Batteriji mejta jew installati ħażin. | Ibdel il-batteriji b'oħrajn ġodda, filwaqt li tiżgura polarità korretta. |
| Qari mhux preċiż. | Microphone obstructed, device needs calibration, or incorrect measurement mode. | Ensure microphone is clear. Perform calibration. Check if Auto/Manual ranging is set appropriately. |
| SD card logging not working. | SD card not inserted correctly, card full, or card error. | Reinsert SD card. Check available space. Try a different SD card. Ensure logging function is activated. |
| Id-displej huwa vojt jew iffriżat. | Low battery or system error. | Replace batteries. If problem persists, remove batteries for a few minutes and reinsert to reset the device. |
Speċifikazzjonijiet
- Mudell: SDL600
- Eżattezza: ±1.4 dB
- Standards: Meets ANSI and IEC 61672-2013 Class 2
- Tvarja: Auto jew Manwal
- Logging tad-Data: External SD card (Excel format), User programmable samprata tal-ling (1 sa 3600 sekonda)
- Memorja Interna: Stores 99 readings manually
- Funzjonijiet: Min/Max, Peak Hold, Data Hold
- Qawwa: 6 AA batteries (included), Optional AC Adaptor UA100-240
- Mitfi Awtomatiku: Yes, with disable capability
- Piż: Madwar 11.99 Liri (5.44 kg)
- Manifattur: EXTECH
Garanzija u Appoġġ
For warranty information and technical support, please refer to the official EXTECH webis-sit jew ikkuntattja lid-distributur lokali tiegħek. Żomm l-irċevuta tax-xiri tiegħek bħala prova tax-xiri għal talbiet ta' garanzija.
Manifattur: EXTECH
ASIN: B0DVYXV4CS