1. Introduzzjoni
This manual provides comprehensive instructions for the installation, operation, and maintenance of your Cadet T521-W 5280W Single Pole Thermostat. Please read this manual thoroughly before installation and use to ensure safe and efficient operation.

Figura 1: Quddiem view of the Cadet T521-W Single Pole Thermostat. It is white with a prominent circular dial in the center, marked with temperature settings from 50 to 90 degrees Fahrenheit. The dial allows for manual temperature control.
2. Informazzjoni Importanti dwar is-Sigurtà
TWISSIJA: Risk of electric shock. Installation must be performed by a qualified electrician in accordance with all local and national electrical codes. Disconnect power at the main service panel before installing or servicing this thermostat.
- Always turn off power at the circuit breaker or fuse box before installation or maintenance.
- Kun żgur li l-konnessjonijiet tal-wajers kollha huma siguri u iżolati kif suppost.
- Do not use this thermostat with heating systems exceeding its specified voltage u wattage klassifikazzjonijiet.
- This thermostat is designed for use with electric baseboard heaters and wall heaters.
- Keep the thermostat dry and away from sources of moisture.
3. Kontenut tal-Pakkett
Iċċekkja li l-oġġetti kollha huma preżenti qabel tibda l-installazzjoni:
- Cadet T521-W Single Pole Thermostat (1 unit)
- Mounting Screws (quantity may vary)
- Manwal ta 'Istruzzjoni (dan id-dokument)
4. Speċifikazzjonijiet tal-Prodott
| Karatteristika | Speċifikazzjoni |
|---|---|
| Mudell | T521-W |
| Brand | Kadetti |
| Kulur | Abjad |
| VoltagKlassifikazzjoni e | 120/240 Volts |
| Wat Massimutage Ikkontrollat | 5280W |
| Ampetà | 22 Amps |
| Tip ta' Termostat | Heating, Single Pole |
| Tip ta' Kontrollur | Ċempel |
| Tip ta' Kontroll tat-Temperatura | Manwal |
| Teknoloġija tal-Konnettività | Bil-fili |
| Sors tal-Enerġija | Corded Elettriku |
| Tip ta 'Immuntar | Mount Wall |
| Materjal | Plastik |
| Tip ta 'Wiri | Analogu |
| Dimensjonijiet tal-Prodott | 3 x 6.7 x 9.1 pulzieri |
| Piż tal-oġġett | 0.16 uqija (madwar 0.01 lbs) |
| UPC | 027418083005 |
5. Installazzjoni u Setup
Qabel ma tibda: Ensure power to the heating circuit is OFF at the main electrical panel. Failure to do so may result in electric shock or damage to the thermostat and heating system.
5.1 Għodod Meħtieġa
- Tornavit (Phillips jew b'ras ċatta, skont it-tip ta' kamin)
- prodotti għat-tqaxxir tal-wajer
- Electrical tape (optional, for insulation)
- Voltagtester
5.2 Post tal-Immuntar
Install the thermostat on an interior wall, approximately 5 feet (1.5 meters) above the floor. Avoid locations near heat sources (e.g., lamps, direct sunlight, fireplaces), cold drafts (e.g., windows, doors), or areas with poor air circulation.
5.3 Wiring Instructions (Single Pole)
- Itfi l-enerġija: Locate the circuit breaker controlling your heating system and switch it to the OFF position. Verify power is off using a voltagtester.
- Remove old thermostat (if applicable): Carefully remove the old thermostat from the wall box. Disconnect the wires, noting which wire was connected to which terminal.
- Qabbad termostat ġdid: The Cadet T521-W is a single pole thermostat. It has two wires for connection.
- Connect one thermostat wire to the incoming power wire from the electrical panel.
- Connect the other thermostat wire to the wire leading to your electric heater.
- Immonta t-termostat: Gently push excess wire back into the wall box. Secure the thermostat to the wall box using the provided mounting screws.
- Irrestawra l-qawwa: Once the thermostat is securely mounted and all connections are checked, turn the power back ON at the main electrical panel.
6. Istruzzjonijiet Operattivi
The Cadet T521-W thermostat features a simple manual dial for temperature control.
- Aġġusta tat-Temperatura: Rotate the central dial clockwise to increase the desired temperature or counter-clockwise to decrease it. The dial is marked in degrees Fahrenheit (50°F to 90°F).
- Indikatur tat-Tisħin: This thermostat does not have a separate heating indicator light. The heating system will activate when the room temperature falls below the set temperature and deactivate when it reaches the set temperature.
- Itfi: To turn off the heating system completely via the thermostat, rotate the dial to its lowest setting (typically "OFF" or below 50°F, depending on the specific dial markings). For complete power disconnection, turn off the circuit breaker.
7. Manutenzjoni
It-termostat Cadet T521-W jeħtieġ manutenzjoni minima.
- Tindif: Imsaħ il-barra tat-termostat perjodikament b'ċarruta ratba u nadifa.amp drapp. Tużax prodotti tat-tindif jew solventi li joborxu. Kun żgur li l-ebda likwidu ma jidħol fil-kaxxa tat-termostat.
- Fluss tal-arja: Ensure that the vents at the bottom of the thermostat are not obstructed, as these are necessary for proper temperature sensing.
- L-ebda Partijiet li jistgħu jservu mill-utent: There are no user-serviceable parts inside the thermostat. Do not attempt to open or repair the unit.
8 Issolvi l-problemi
Jekk tesperjenza problemi bit-termostat tiegħek, irreferi għall-problemi u s-soluzzjonijiet komuni li ġejjin:
| Problema | Kawża Possibbli | Soluzzjoni |
|---|---|---|
| Il-ħiter mhux qed jixgħel. |
|
|
| Il-ħiter mhux qed jintefa. |
|
|
| Inaccurate temperature reading/control. |
|
|
If troubleshooting steps do not resolve the issue, contact Cadet customer support or a qualified electrician.
9. Informazzjoni dwar Garanzija
Cadet products are manufactured to high-quality standards. For specific warranty details regarding your T521-W thermostat, please refer to the warranty card included with your purchase or visit the official Cadet websit. Żomm l-irċevuta tax-xiri tiegħek bħala prova tax-xiri għal talbiet ta' garanzija.
10. Appoġġ għall-Klijent
For technical assistance, replacement parts, or further information, please contact Cadet customer support:
- Websit: www.cadetheat.com
- Telefon: Irreferi għall-manifattur webis-sit jew l-imballaġġ tal-prodott għan-numri ta' kuntatt attwali.
When contacting support, please have your model number (T521-W) and purchase date available.