The Cooler Master 240 Core II White CPU Liquid Cooler is an all-in-one (AIO) liquid cooling solution designed to provide efficient thermal management for your CPU. It features a G9R dual-chamber pump, customizable aRGB lighting, and is engineered for quiet operation and easy installation. This manual provides detailed instructions for the proper installation, operation, and maintenance of your liquid cooler.

Cooler Master 240 Core II White CPU Liquid Cooler

Image 1.1: Cooler Master 240 Core II White CPU Liquid Cooler with RGB fans and pump head.

Vidjo 1.1: Overview of the Cooler Master MasterLiquid Core II features and design.

2. Informazzjoni dwar is-Sigurtà

Please read and understand all safety instructions before installing or operating this product. Failure to follow these instructions may result in damage to the product, personal injury, or voiding of your warranty.

  • Kun żgur li s-sistema tal-kompjuter tiegħek tkun mitfija u skonnettjata mis-sokit tal-ħajt qabel l-installazzjoni.
  • Immaniġġja l-komponenti b'attenzjoni biex tevita l-ħsara.
  • Wear anti-static gloves or use an anti-static wrist strap to prevent electrostatic discharge (ESD) damage to sensitive components.
  • Do not open the liquid cooler's pump or radiator. It is a sealed, maintenance-free unit.
  • Żomm il-prodott 'il bogħod minn likwidi u umdità.
  • Ensure all cables are properly connected and routed to avoid interference with moving parts (e.g., fans).

3. Konfigurazzjoni u Installazzjoni

3.1. Kontenut tal-Pakkett

Ivverifika li l-komponenti kollha huma preżenti fil-pakkett:

  • Cooler Master 240 Core II AIO Liquid Cooler (Radiator, Pump, Fans, Tubing)
  • Mounting Hardware for AMD (AM5/AM4) and Intel (LGA 1851/1700) sockets
  • Pejst Termali CryoFuze
  • Clips tat-tubi
  • Manwal għall-Utent

Video 3.1: Unboxing the MasterLiquid 240 Core II, showing included components and mounting hardware.

3.2. Passi ta 'qabel l-installazzjoni

  1. Ipprepara l-Motherboard tiegħek: Install your CPU, RAM, and M.2 SSDs onto the motherboard before installing the cooler. Refer to your motherboard's manual for specific instructions.
  2. Applika Pejst Termali: Apply a small amount of the included CryoFuze thermal paste to the center of your CPU's integrated heat spreader (IHS). A pea-sized dot is generally sufficient. Do not spread it manually; the pressure from the cold plate will distribute it evenly.
Applying CryoFuze Thermal Paste to CPU

Image 3.2: Illustration of applying CryoFuze thermal paste to the CPU.

3.3. Radiator and Fan Installation

The 240mm radiator is designed to fit most standard PC cases that support 240mm AIOs. It is typically mounted at the top or front of the case.

  1. Attach Fans to Radiator: Secure the two 120mm fans to the radiator using the provided screws. Ensure the fan airflow direction is appropriate for your case's cooling strategy (e.g., exhaust out the top, intake from the front).
  2. Mount Radiator in Case: Position the radiator assembly in your desired mounting location (e.g., top panel) and secure it with the appropriate screws.
Compact Fin Array Radiator Dimensions

Image 3.3: Diagram showing the compact fin array and dimensions of the radiator (277 x 119.2 x 27.2 mm).

3.4. Pump/Cold Plate Installation

The pump/cold plate assembly connects directly to your CPU.

  1. Select Mounting Brackets: Choose the correct mounting brackets for your CPU socket (AMD AM5/AM4 or Intel LGA 1851/1700).
  2. Attach Brackets to Pump: Secure the chosen brackets to the pump head.
  3. Install Pump onto CPU: Carefully align the pump/cold plate assembly with the CPU and secure it using the appropriate screws and backplate (if required for your socket). Ensure even pressure is applied.
Cooler Master Simplify Brackets for AMD and Intel Sockets

Image 3.4: Visual guide for selecting and installing mounting brackets for AMD AM5/AM4 and Intel LGA 1851/1700 platforms.

3.5. Konnessjonijiet tal-kejbil

Proper cable management is crucial for aesthetics and airflow.

  1. Konnessjonijiet tal-Fann: Connect the fan cables to the CPU_FAN header or a dedicated fan controller on your motherboard. The fans feature a daisy-chain design for simplified connection.
  2. Konnessjoni tal-Pompa: Connect the pump power cable to the AIO_PUMP or CPU_OPT header on your motherboard.
  3. Dawl ARGB: Connect the aRGB cables from the fans and pump to a compatible 3-pin 5V aRGB header on your motherboard or an aRGB controller.
  4. Tube Clips: Use the included tube clips to manage the tubing for a cleaner look and to prevent interference.
Cooler Master Tube Clips Included for Liquid Cooler Tubing

Immaġni 3.5: Eż.ample of using tube clips to secure the liquid cooler's tubing.

Video 3.6: A build video demonstrating the installation of various PC components, including the Cooler Master AIO liquid cooler.

4. Operazzjoni

4.1. L-Ewwel Tixgħil

After completing the installation, double-check all connections before powering on your system. Upon first boot, monitor your CPU temperatures to ensure the cooler is functioning correctly.

4.2. Kontroll tad-Dawl ARGB

The Cooler Master 240 Core II features customizable Addressable RGB (aRGB) lighting on both the fans and the pump head's infinity mirror design. Control is typically managed through your motherboard's aRGB software (e.g., ASUS Aura Sync, GIGABYTE RGB Fusion, MSI Mystic Light Sync, ASRock Polychrome RGB) or a dedicated aRGB controller (not included).

Cooler Master Infinity Mirror Design Pump Head with ARGB Lighting

Image 4.1: Close-up of the pump head showcasing the infinity mirror design with vibrant ARGB lighting.

Cooler Master Frosted Blade Design Fans with ARGB Lighting

Image 4.2: The frosted fan blades diffusing ARGB lighting for a dynamic glow.

4.3. Kontroll tal-veloċità tal-fann

The fans are Dynamic PWM (Pulse Width Modulation) controlled, allowing for adjustable fan speeds from 650 to 1,750 RPM. This balance between noise and airflow can be configured via your motherboard's BIOS settings or fan control software.

Cooler Master MF120 Lite Fan Specifications

Image 4.3: Specifications of the MF120 Lite fan, including speed (1750 RPM), noise level (30 dBA max), airflow (70.5 CFM), and air pressure (2.0 mmH2O).

Cooler Master Dynamic PWM Fan Speed Range

Image 4.4: Visual representation of the dynamic PWM fan speed range from 650 to 1,750 RPM.

5. Manutenzjoni

The Cooler Master 240 Core II is designed to be a maintenance-free closed-loop liquid cooler. No refilling of coolant is required.

  • Tindif tat-Trab: Periodically clean the radiator fins and fan blades to prevent dust buildup, which can impede airflow and reduce cooling performance. Use compressed air or a soft brush.
  • Spezzjona Tubi: Occasionally check the tubing for any signs of wear, kinks, or leaks. While rare, early detection can prevent potential issues.
  • Monitora Temperaturi: Regularly monitor your CPU temperatures using system monitoring software to ensure optimal performance.

6 Issolvi l-problemi

6.1. Temperaturi Għolja tas-CPU

  • Iċċekkja l-Konnessjoni tal-Pompa: Ensure the pump is correctly connected to the AIO_PUMP or CPU_OPT header and receiving power.
  • Ivverifika l-Kuntatt tal-Pjanċa Bierda: Confirm that the cold plate is making full and even contact with the CPU's IHS. Re-seat the pump if necessary, ensuring thermal paste is properly applied.
  • Funzjonalità tal-fann: Check if the fans are spinning. Ensure they are connected correctly and configured to an appropriate speed in BIOS/software.
  • Fluss tal-Arja tar-Radjatur: Ensure the radiator fins are not clogged with dust. Clean if necessary.

6.2. ARGB Lighting Not Working

  • Check ARGB Connections: Ensure all aRGB cables are securely connected to a compatible 3-pin 5V aRGB header on your motherboard or controller.
  • Konfigurazzjoni tas-Softwer: Verify that your motherboard's aRGB software is installed and configured correctly.
  • Ċiklu tal-Enerġija: Sometimes a full system power cycle can resolve minor lighting glitches.

6.3. Ħsejjes Mhux tas-Soltu

  • Ħoss tal-fann: Check for any cables interfering with fan blades. Ensure fans are securely mounted and not vibrating against the case.
  • Storbju tal-Pompa: A slight gurgling sound upon initial startup is normal as air bubbles clear. If persistent or loud, ensure the radiator is mounted higher than the pump to allow air to collect in the radiator.

7. Speċifikazzjonijiet

KaratteristikaDettall
Numru tal-MudellMLW-D24M-A18PA-RW
Dimensjonijiet tal-Prodott10.9"T x 4.7"W x 1.1"Għ (277 x 119.2 x 27.2 mm)
BrandCooler Master
Metodu tat-tkessiħFann, Ilma
Apparati KompatibbliCPU, Desktop (AMD Ryzen 7 AM5|4, Intel Ultra 7 LGA 1851|1700)
Livell ta' Storbju30 Deċibel (Massimu)
MaterjalAluminum, Copper, Plastic
Veloċità ta' Rotazzjoni Massima1750 RPM
Kapaċità tal-Fluss tal-Ajru70.5 pied kubu fil-minuta (CFM)
Tip ta 'Konnettur tal-Enerġija3-Pin (Fans), Specific Pump Connector (refer to motherboard manual)
Pejst TermaliCryoFuze (14W/mK conductivity)

8. Garanzija u Appoġġ

8.1. Informazzjoni dwar Garanzija

Cooler Master products come with a limited warranty. The specific warranty period and terms may vary by region and product type. Please retain your proof of purchase for warranty claims. For detailed warranty information, please visit the official Cooler Master websit.

8.2. Appoġġ Tekniku

If you encounter any issues or have questions not covered in this manual, please contact Cooler Master technical support. You can find support resources, FAQs, and contact information on the official Cooler Master websit:

Uffiċjali tal-Cooler Master Websit: www.coolermaster.com

For additional product information and community support, you may also visit the Cooler Master Store on Amazon: Cooler Master Store

Dokumenti Relatati - MLW-D24M-A18PA-RW

Preview Manwal tal-Utent tal-Cooler Likwidu tas-CPU Cooler Master MasterLiquid ML240L V2 ARGB
Manwal komprensiv għall-utent għall-Cooler Master MasterLiquid ML240L V2 ARGB All-In-One (AIO) li jkopri l-installazzjoni, il-partijiet, u s-soluzzjoni tal-problemi.
Preview Manwal tal-Utent tal-Cooler Master MasterLiquid ML240L V2 ARGB
Manwal tal-utent għall-coolers likwidi tas-CPU Cooler Master MasterLiquid ML240L V2 ARGB u MasterLiquid ML240L V2 ARGB White Edition, li jagħti dettalji dwar l-installazzjoni u l-identifikazzjoni tal-komponenti.
Preview Manwal tal-Utent u Gwida għall-Installazzjoni tas-Serje Cooler Master MasterLiquid Core
Manwal komprensiv għall-utent u gwida għall-installazzjoni għal Cooler Master MasterLiquid 120L, 240L, u 360L Core CPU liquid coolers, inklużi l-varjanti ARGB u White. Ikopri l-kompatibilità tas-sokits Intel u AMD, lista tal-partijiet, u dijagrammi tal-konnessjoni.
Preview Manwal tal-Utent u Gwida għall-Installazzjoni ta' Cooler Master MasterLiquid 240/360 Atmos
Dan id-dokument jipprovdi manwal komprensiv għall-utent u gwida għall-installazzjoni tal-Cooler Master MasterLiquid 240 Atmos u 360 Atmos, apparati li jkessħu s-CPU likwidi all-in-one. Jiddeskrivi l-partijiet inklużi u jipprovdi struzzjonijiet pass pass għall-installazzjoni fuq pjattaformi Intel (LGA 1700, 1200, 115X) u AMD (AM4, AM5), inklużi l-konnessjonijiet tal-fann u tal-ARGB.
Preview Manwal tal-Utent tal-Cooler Master MasterLiquid ML360L V2 ARGB
Manwal komprensiv għall-utent għall-Cooler Master MasterLiquid ML360L V2 ARGB u ML360L V2 ARGB White Edition All-In-One Liquid CPU Cooler. Jinkludi lista tal-partijiet, gwidi dettaljati tal-installazzjoni għas-sokits Intel u AMD, struzzjonijiet dwar il-wajers, u noti dwar is-soluzzjoni tal-problemi.
Preview Manwal tal-Utent tas-Serje Cooler Master MasterLiquid Core
Manwal komprensiv għall-utent għall-coolers likwidi tas-CPU tas-serje Cooler Master MasterLiquid Core, li jkopri l-installazzjoni għal diversi sokits tal-Intel u tal-AMD, il-konnettività tal-fann u tal-ARGB, u noti inizjali tal-istartjar.