1. Introduzzjoni
The Sper Scientific Benchtop Water Quality Meter Model 860033 is a multi-parameter instrument designed for precise measurement of various water quality indicators. This device accurately measures pH, Oxidation-Reduction Potential (ORP), millivolts (mV), conductivity, Total Dissolved Solids (TDS), salinity, and temperature. It is suitable for a wide range of applications in laboratories and industrial environments, offering features such as automatic calibration and temperature compensation.

Figure 1: Sper Scientific Benchtop Water Quality Meter Model 860033 in operation, measuring pH in a beaker.
2. Setup
2.1 Żpakkjar u Komponenti
Iftaħ il-komponenti kollha bir-reqqa mill-pakkett u vverifika li l-oġġetti li ġejjin huma inklużi:
- Sper Scientific Benchtop Water Quality Meter 860033
- Conductivity Electrode (also measures TDS and Salinity)
- pH Electrode (also measures mV)
- Multiple Electrodes Holder Arm
- Adapter AC
- Kejbil tal-Kompjuter
- Software CD

Figure 2: All included components of the Benchtop Water Quality Meter, including the main unit, electrodes, power adapter, and accessories.
2.2 Connecting Electrodes and Power
- Attach the Electrode Holder Arm: Securely attach the multiple electrodes holder arm to the side of the meter unit.
- Qabbad l-Elettrodi: Connect the pH electrode to the BNC connector on the rear panel. Connect the conductivity electrode to its designated port.
- Connect AC Adaptor: Plug the AC adaptor into the DC input port on the rear of the meter, then connect it to a standard power outlet. The meter operates on AC voltage and does not use batteries.
- Optional PC Connection: For data logging and analysis, connect the computer cable to the RS232 port on the meter and to your computer. Install the provided software.

Figure 3: Rear panel of the meter showing DC power input, RS232 port, analog outputs, and BNC/ATC connections for electrodes.
3. Istruzzjonijiet Operattivi
3.1 Power On/Off
Agħfas il- QAWWA button to turn the meter on. The large LCD will display the current parameter, time, date, and temperature. Press the QAWWA button again to turn the meter off.
3.2 Għażla tal-Parametru
Uża l- MODALITÀ button to cycle through the available measurement parameters: pH, ORP, mV, Conductivity, TDS, Salinity, and Temperature.
3.3 Kalibrazzjoni
The meter features automatic buffer recognition for pH calibration and supports 5 calibration points. Refer to the detailed calibration procedure in the full instruction manual for each specific parameter (pH, ORP, Conductivity, TDS, Salinity).
- Kalibrazzjoni tal-pH: Use standard pH buffer solutions. The meter will automatically recognize the buffer values.
- Conductivity/TDS/Salinity Calibration: Use appropriate standard solutions.
3.4 Teħid tal-Kejl
- Ensure the appropriate electrode is connected and properly conditioned.
- Select the desired measurement parameter using the MODALITÀ buttuna.
- Immerse the electrode(s) into the sample solution. Ensure the sensor part of the electrode is fully submerged.
- Allow the reading to stabilize. The meter provides automatic or manual temperature compensation and ranging.
- The LCD will display the stable measurement.
- Uża l- HOLD/REC button to hold the current reading or record data (if connected to PC with software).
4. Manutenzjoni
4.1 Kura tal-Elettrodi
- Elettrodu tal-pH: Always keep the pH electrode bulb moist. Store it in a suitable storage solution or pH 4 buffer when not in use. Never store in distilled water.
- Conductivity Electrode: Rinse the conductivity electrode with distilled water after each use. Store dry or in a conductivity storage solution as recommended.
- Tindif: Clean electrodes regularly according to the full manual's instructions to prevent buildup that can affect accuracy.
4.2 Meter Cleaning
Wipe the meter's housing with a soft, damp cloth. Do not use abrasive cleaners or solvents. Ensure no liquid enters the meter's ports or openings.
4.3 Ħażna
When not in use for extended periods, disconnect the AC adaptor and store the meter and electrodes in a clean, dry environment within the specified operating temperature range.
5 Issolvi l-problemi
This section addresses common issues you might encounter with your Sper Scientific Benchtop Water Quality Meter 860033.
- Qari Instabbli: If readings are unstable, ensure electrodes are properly conditioned and calibrated. Gently stir the sample solution around the probe to help readings settle. Check for air bubbles on the electrode surface.
- Qari mhux eżatt: Recalibrate the meter with fresh standard solutions. Check electrodes for damage or contamination. Ensure temperature compensation is correctly applied.
- Meter Not Powering On: Verify the AC adaptor is securely connected to both the meter and a working power outlet.
- No Communication with PC: Ensure the computer cable is correctly connected and the software drivers are installed. Check the RS232 port settings on your computer.
For more detailed troubleshooting steps, please refer to the comprehensive instruction manual provided with your device or contact Sper Scientific customer support.
6. Speċifikazzjonijiet
The following table outlines the measurement ranges, resolutions, and accuracies for the Sper Scientific Benchtop Water Quality Meter Model 860033.

Figure 4: Detailed specifications including measurement ranges, resolutions, and accuracies for pH, mV/ORP, Conductivity, TDS, Salinity, and Temperature.
| Karatteristika | Dettall |
|---|---|
| Dimensjonijiet | 8.5-il pulzier (L) x 6.5-il pulzier (W) x 2.25-il pulzier (H) |
| Sors tal-Enerġija | AC Adaptor (no batteries required) |
| Outputs | Digital (RS232), Analog |
| Kumpens tat-Temperatura | Awtomatiku jew Manwal |
| pH Buffer Rikonoxximent | Awtomatiku |
| Punti ta' Kalibrar | 5 |
| Ċertifikazzjonijiet | Approvat CE |
7. Informazzjoni dwar Garanzija
Sper Scientific products are manufactured under strict quality control standards. For specific warranty terms and conditions, please refer to the warranty card included with your product or visit the official Sper Scientific websit. Żomm l-irċevuta tax-xiri tiegħek bħala prova tax-xiri għal kwalunkwe talba ta' garanzija.
8. Appoġġ għall-Klijent
If you require technical assistance, have questions about your meter, or need to order replacement parts, please contact Sper Scientific customer support. Contact information can typically be found on the product packaging, the official website, or the full instruction manual.
Sper Scientific Contact Information:
- Websit: www.sperscientific.com (for product information, FAQs, and support resources)
- Email/Telefon: Irreferi għall- website or product documentation for the most current contact details.