ACiQ B0DHFF2DKL

Manwal tal-Utent tas-Sistema ta' Pompa tas-Sħana b'Inverter Ċentrali ACiQ 2.5 Tunnellata 17 SEER2

Model: B0DHFF2DKL

1. Introduzzjoni

This manual provides essential information for the installation, operation, and maintenance of your ACiQ 2.5 Ton 17 SEER2 Central Inverter Heat Pump System. This system is designed to provide efficient heating and cooling for residential and light commercial applications. Please read this manual thoroughly before attempting any installation or operation to ensure proper function and safety.

2. Informazzjoni dwar is-Sigurtà

Always prioritize safety. Improper installation, adjustment, alteration, service, or maintenance can cause property damage, injury, or death. Consult a qualified installer, service agency, or the gas supplier for information or assistance. The information contained in this manual is intended for use by qualified service personnel only.

  • Sigurtà Elettrika: Ensure the power supply is disconnected before performing any service or maintenance. All electrical wiring must comply with local and national electrical codes.
  • Immaniġġjar tar-refriġerant: This system uses R-454B refrigerant. Only certified technicians should handle refrigerants.
  • Installazzjoni: L-installazzjoni għandha titwettaq minn professjonist liċenzjat tal-HVAC.
  • Tagħmir Protettiv Personali: Always wear appropriate personal protective equipment (PPE) such as gloves and safety glasses during installation and maintenance.

3. Karatteristiċi ewlenin

  • Teknoloġija tal-inverter: Provides precise temperature control, reduced energy consumption, and quieter operation.
  • Effiċjenza Għolja: 18.8 SEER2 and 9.7 HSPF2 ratings for energy savings.
  • Medda Operattiva Wiesgħa: Reliable performance from -13°F to 122°F.
  • Operazzjoni kwieta: Indoor noise levels as low as 44 dBA, outdoor unit at 60 dBA.
  • Komponenti Durabbli: Rotary compressor, aluminum coil, and fiberglass-free insulation.
  • Refriġerant favur l-Eko: Utilizes R-454B refrigerant.
  • Installazzjoni flessibbli: Supports horizontal and vertical air handler installation.
  • Kontrolli intelliġenti: Compatible with wired controllers, WiFi, and third-party thermostats.
  • Integrated Back-up Heat: Includes a 10kW back-up heat kit for supplemental heating.

4. Komponenti Overview

The ACiQ 2.5 Ton 17 SEER2 Central Inverter Heat Pump System includes the following main components:

  • Outdoor Condensing Unit (Heat Pump)
  • Indoor Air Handler Unit
  • 10kW Back-up Heat Kit
  • 30' Line Set
  • Gauge Electrical Whip
  • 60A Non-Fused Disconnect Switch
  • Termostat WiFi
  • Protettur ta 'Kontra l-Vultaġġ
  • CPS Charging Adapter
  • Kmiem tal-Ħajt
ACiQ 2.5 Ton 17 SEER2 Central Inverter Heat Pump System components

Figura 1: Fuqview of the ACiQ 2.5 Ton 17 SEER2 Central Inverter Heat Pump System, showing the outdoor unit, indoor air handler, 10kW back-up heat kit, thermostat, line set, and various installation accessories.

5. Setup u Installazzjoni

Installation of this ACiQ heat pump system requires specialized knowledge and tools. It must be performed by a qualified and licensed HVAC technician to ensure safety, compliance with local codes, and optimal performance. Refer to the detailed installation manual provided with the product for specific instructions.

5.1 Kontrolli ta' qabel l-installazzjoni

  • Verify that the electrical supply matches the unit's requirements (Indoor: 115/208/230V, 60Hz, 1Ph; Outdoor: 208/230V, 60Hz, 1Ph).
  • Aċċerta ruħek li jkun hemm biżżejjed spazju kemm għall-unitajiet ta' ġewwa kif ukoll għal dawk ta' barra, biex ikun hemm fluss tal-arja xieraq u aċċess għall-manutenzjoni.
  • Confirm that the maximum piping length (164 ft / 50m) and height difference (82 ft / 25m) are not exceeded.

5.2 Air Handler Installation

The indoor air handler unit is designed for flexible installation, supporting upflow, downflow, and horizontal configurations to suit various space requirements.

Multi-Positional Air Handler Unit installation options

Figura 2: Diagram illustrating the multi-positional capabilities of the indoor air handler unit, showing options for upflow, downflow, and horizontal installation.

5.3 Pożizzjonament tal-Unità ta' Barra

Consider the outdoor unit's dimensions and required clearances for optimal performance and maintenance. The unit features a compact design compared to traditional systems.

Outdoor unit size comparison with traditional units

Figura 3: Graphic comparing the smaller footprint of the ACiQ outdoor unit (20 inches clearance) versus a traditional unit (36 inches clearance), highlighting its high efficiency and self-cleaning features.

6. Istruzzjonijiet Operattivi

Your ACiQ heat pump system offers advanced control options for comfortable and efficient operation.

6.1 Modi ta' Operazzjoni Bażiċi

  • Modalità tat-tkessiħ: Provides cooling with a capacity of 31,000 BTU/hr. Operates efficiently from -13°F to 122°F ambient temperatures.
  • Modalità tat-Tisħin: Provides heating with a capacity of 30,000 BTU/hr at 47°F. Reliable warmth down to -13°F. The 10kW back-up heat kit provides supplemental heat when needed.
  • Modalità Fan: Jiċċirkola l-arja mingħajr ma jsaħħan jew ikessaħ.
  • Modalità Awtomatika: Jaqleb awtomatikament bejn it-tisħin u t-tkessiħ biex iżomm it-temperatura ssettjata.
ACiQ outdoor unit operating in extreme heat

Figura 4: The ACiQ outdoor unit installed on a patio, demonstrating its ability to operate effectively in extreme heat conditions, up to 122°F.

ACiQ outdoor unit operating in extreme cold

Figura 5: The ACiQ outdoor unit partially covered in snow, illustrating its capability to operate in extreme cold temperatures, down to -13°F.

6.2 Smart Controls

The system can be controlled via the included wired thermostat, WiFi-enabled app, or compatible third-party thermostats. The WiFi app allows for remote control and monitoring of your system.

ACiQ Smart Home app and wired thermostat

Figura 6: Image showing the ACiQ Smart Home mobile application interface on a smartphone alongside a wired thermostat, demonstrating the system's smart control capabilities for climate management.

7. Manutenzjoni

Regular maintenance ensures the longevity and efficiency of your ACiQ heat pump system. Always disconnect power before performing any maintenance.

  • Sostituzzjoni tal-filtru tal-arja: Check and replace air filters in the indoor air handler every 1-3 months, or more frequently if needed. Dirty filters restrict airflow and reduce efficiency.
  • Tindif tal-Unità ta' Barra: Keep the outdoor unit free from debris, leaves, and dirt. Periodically clean the coils with a soft brush or water hose (ensure power is off).
  • Sistema tad-Drenaġġ: Ensure the condensate drain line is clear and free of blockages to prevent water overflow.
  • Spezzjoni Professjonali: Schedule annual inspections and maintenance by a qualified HVAC technician.

8 Issolvi l-problemi

This section provides solutions for common issues. For complex problems, contact a qualified HVAC technician.

  • Ebda Qawwa: Check circuit breakers and ensure the disconnect switch is in the ON position.
  • Tisħin/Tkessiħ Insuffiċjenti: Verify thermostat settings, check air filters for blockage, and ensure outdoor unit is not obstructed.
  • Ħsejjes mhux tas-soltu: Minor operational noises are normal. Loud or unusual noises may indicate a problem requiring professional inspection.
  • Tnixxijiet tal-Ilma: Check condensate drain line for blockages.

9. Speċifikazzjonijiet

Dimensions of ACiQ indoor and outdoor units

Figura 7: Image displaying the dimensions of both the indoor air handler unit (49.02" H x 21.02" W x 21.02" D) and the outdoor condensing unit (35.04" H x 37.24" W x 16.14" D).

Cooling capacity chart for ACiQ heat pump

Figura 8: Chart detailing the cooling capacity of the ACiQ system at various outdoor temperatures: 86°F (118% capacity), 95°F (113% capacity), 110°F (99% capacity), and 122°F (48% capacity).

Heating capacity chart for ACiQ heat pump

Figura 9: Chart detailing the heating capacity of the ACiQ system at various outdoor temperatures: -22°F (N/A), -13°F (41% capacity), 0°F (57% capacity), 17°F (70% capacity), and 32°F (73% capacity).

KaratteristikaDettall
Kapaċità tat-tkessiħ31,000 BTU/hr
Kapaċità tat-tisħin30,000 BTU/hr (at 47°F)
Klassifikazzjoni SEER218.8
Klassifikazzjoni tal-HSPF29.7
Tip ta 'RefriġerantR-454B
Provvista ta 'Enerġija ta' l-Unità ta 'Ġewwa115/208/230V, 60Hz, 1Ph
Outdoor Unit Power Supply208/230V, 60Hz, 1Ph
Tul massimu tal-pajpijiet164 pied (50m)
Max Height Difference82 pied (25m)
Indoor Unit Dimensions (W × D × H)21.02" × 21.02" × 49.02"
Outdoor Unit Dimensions (W × D × H)37.24" × 16.14" × 31.89"
Piż Nett tal-Unità ta' Ġewwa128.97 lbs
Piż Nett tal-Unità ta' Barra164.02 lbs

10. Garanzija u Appoġġ

ACiQ offers a comprehensive warranty for this heat pump system:

  • Garanzija tal-Partijiet: 7 snin
  • Garanzija tal-kompressur: 12 snin

These warranty terms are valid when the system is installed by a certified technician and registered online with the manufacturer. For technical support, service inquiries, or warranty claims, please refer to the contact information provided in your product packaging or visit the official ACiQ websit.

Dokumenti Relatati - B0DHFF2DKL

Preview Sistemi ta' Tisħin Standard ACiQ 9K-24K b'Żona Unika: Installazzjoni u Manwal tas-Sid
Manwal tal-Installazzjoni u s-Sid tas-Sistemi ta' Tisħin Standard ACiQ 9K-24K b'Żona Unika. Din il-gwida tagħti dettalji dwar l-installazzjoni, it-tħaddim, is-sigurtà, u l-manutenzjoni għall-kondizzjonaturi tal-arja ACiQ, inklużi l-ispeċifiċitajiet tal-mudell u informazzjoni dwar ir-refriġerant R454B.
Preview Manwal tal-Installazzjoni tas-Sistemi tal-Inverter Ċentrali ACiQ
Manwal komprensiv tal-installazzjoni għas-Sistemi tal-Arja Kundizzjonata u l-Pompa tas-Sħana b'Inverter Ċentrali ACiQ, li jagħti dettalji dwar il-prekawzjonijiet ta' sigurtà, il-pajpijiet tar-refriġerant, l-installazzjoni tal-unità ta' barra, il-wajers, l-ispeċifikazzjonijiet tal-enerġija, l-evakwazzjoni tal-arja, u l-proċeduri tat-test.
Preview Installazzjoni u Manwal tas-Sid ta' ACiQ Air Handler Imwaħħal mal-Ħajt u Kondensatur ta' Żona Unika għal Sħana Estrema
Dan il-manwal jipprovdi linji gwida dettaljati dwar l-installazzjoni, it-tħaddim, u s-sigurtà għall-air handlers ACiQ immuntati mal-ħajt u l-kondensaturi b'żona waħda ta' sħana estrema, li jkopru l-mudelli ACIQ-06W-HH-MD sa ACIQ-24ZPL-HP230C.
Preview Manwal tal-Installazzjoni tal-Unità ta' Barra tas-Sistemi ta' Inverter Ċentrali ACiQ
Manwal komprensiv tal-installazzjoni għall-unitajiet ta' barra tas-Sistemi ACiQ Central Inverter, li jkopri l-prekawzjonijiet ta' sigurtà, il-pajpijiet tar-refriġerant, il-wajers, l-installazzjoni tal-unità, u l-proċeduri tal-ittestjar għal mudelli bħal ACiQ-18-AC, ACiQ-24-AC, ACiQ-18-EHPB, u oħrajn.
Preview Sistema ta' Pompa tas-Sħana bil-Kannali ACiQ Next Gen: Gwida ta' Bidu Mgħaġġel għall-Wajers tat-Termostat
Din il-gwida tipprovdi informazzjoni essenzjali għall-konnessjoni u l-wajers tat-termostati mas-Sistema tal-Pompa tas-Sħana bil-Katus ACiQ Next Gen. Tiddeskrivi l-għażliet ta' konnessjoni rakkomandati u alternattivi, inklużi s-settings tas-swiċċijiet DIP u l-konfigurazzjonijiet tal-blokka tat-terminals għal diversi tipi ta' termostati.
Preview Manwal tal-Installazzjoni u s-Sid tal-ACiQ Essentials Mini-Split Air Handler & Condenser
Comprehensive installation and owner's manual for ACiQ Essentials Mini-Split Air Handler and Condenser systems, covering safety precautions, parts identification, remote control operation, installation procedures, test runs, maintenance, and troubleshooting for various models. The manual also includes critical information regarding the servicing of systems using flammable refrigerant R454B, emphasizing safety protocols and regulatory compliance. It is designed for professional installers and end-users to ensure safe and efficient operation of ACiQ mini-split heat pump systems.