TRACEABLE AO-94460-07

Traceable Excursion-Trac Data Logging Thermometer User Manual

Model: AO-94460-07

1. Introduzzjoni

The Traceable Excursion-Trac Data Logging Thermometer is designed for precise and reliable temperature monitoring and data logging. This device is ideal for applications requiring continuous temperature tracking and historical data retrieval. It features a clear LCD display, alarm functions, and the ability to log a significant number of temperature observations.

Traceable Excursion-Trac Data Logging Thermometer with bottle probe and USB drive.

Quddiem view of the Traceable Excursion-Trac thermometer, showing the main display, control buttons, connected bottle probe, and a USB flash drive for data transfer.

2. Setup

2.1 Disimballaġġ

Carefully unpack all components. The package should contain:

  • Traceable Excursion-Trac Data Logging Thermometer unit
  • 1 Bottle Probe
  • 2 Batteriji AAA
  • Manwal ta 'Istruzzjoni (dan id-dokument)

2.2 Installazzjoni tal-batterija

  1. Sib il-kompartiment tal-batterija fuq wara tat-termometru.
  2. Iftaħ l-għatu tal-kompartiment.
  3. Daħħal żewġ (2) batteriji AAA, waqt li tiżgura l-polarità korretta (+/-).
  4. Close the battery compartment cover securely. The device will power on automatically.

2.3 Konnessjoni tas-Sonda

Connect the bottle probe cable to the designated probe input port (labeled P1 or P2) on the side of the thermometer unit. Ensure the connection is firm.

Lura view of Traceable Excursion-Trac thermometer with kickstand.

Wara view of the thermometer, illustrating the integrated kickstand for desktop placement and wall-mount slot.

3. Istruzzjonijiet Operattivi

3.1 Power On/Off

The device powers on automatically upon battery installation. To turn off the device, remove the batteries. For temporary power saving, some models may have an ON/OFF switch for the alarm or display backlight, but the main unit remains active for logging.

3.2 Display Overview

The LCD display shows various information:

  • Temperatura Kurrenti: The primary reading from the connected probe(s).
  • MIN / MAX: Minimum and maximum temperatures recorded since the last reset.
  • MEM: Indicates memory status or data logging activity.
  • ALLARM: Indicates alarm status (active, triggered).
  • DATA/ĦIN: Current date and time for logged events.
Traceable Excursion-Trac thermometer displaying current date and time.

The thermometer display showing the current date and time, indicating its time-keeping functionality for logged data.

3.3 Għażla tal-Unità (°C/°F)

Agħfas il- UNITÀ button to toggle between Celsius (°C) and Fahrenheit (°F) temperature scales.

3.4 Viewing Min/Max/Date/Time

Agħfas il- MIN/MAX/ALARM-DATE/TIME button to cycle through the minimum temperature, maximum temperature, and current date/time displays. The display will show the recorded minimum and maximum temperatures since the last reset.

3.5 Funzjoni ta 'allarm

The thermometer features programmable high and low alarms. When the temperature exceeds or falls below the set limits, an audible and visual alarm will activate.

  1. Issettjar ta' Allarmi: Uża l- SELECT/ADVANCE u ALARM DATE SET buttons to navigate and adjust the high and low temperature thresholds. Refer to the on-screen prompts for specific steps.
  2. Allarm mixgħul/mitfi: Uża l- ALLARM ON / OFF switch to enable or disable the alarm function.
  3. Silenzju Allarm: Agħfas il- SKONT ALLARM button to temporarily mute an active alarm.
  4. Event Display: Il- EVENT DISPLAY button allows viewing of recorded alarm events. The device can store up to 10 individual alarm events.

3.6 Data Logging and Retrieval

The Excursion-Trac thermometer automatically logs temperature data. It can store up to 525,600 temperature observations. To retrieve logged data:

  1. Connect the thermometer to a computer using a standard USB cable (not always included, check package contents).
  2. The device should appear as a removable storage device.
  3. Access the logged data files (typically in a CSV or similar format) from the device's storage.
  4. Ikkopja l- files to your computer for analysis.
Ġenb view of Traceable Excursion-Trac thermometer showing USB port.

Ġenb view of the thermometer, clearly showing the USB port for data transfer and the power input.

4. Manutenzjoni

4.1 Sostituzzjoni tal-batterija

When the low battery indicator appears on the display, replace the two AAA batteries immediately. Ensure new batteries are inserted with correct polarity.

4.2 Tindif

Wipe the thermometer unit and probes with a soft, damp cloth. Do not use abrasive cleaners or immerse the main unit in liquids. The bottle probe is designed for use in various environments, including freezers.

4.3 Kalibrazzjoni

The Traceable Excursion-Trac thermometer is supplied with an individually calibrated and certified NIST-traceable certificate. For continued accuracy and compliance, periodic recalibration is recommended according to your facility's protocols or regulatory requirements.

5 Issolvi l-problemi

  • "Battery Low" Message: Replace the two AAA batteries immediately. Ensure new batteries are inserted with correct polarity.
  • Qari mhux eżatt: Verify that the probe is securely connected to the unit. Ensure the probe is correctly positioned within the environment being monitored. Check for any visible damage to the probe cable or sensor.
  • Data Download Issues: Ensure the USB cable is properly connected to both the thermometer and the computer. Try a different USB port or cable. If the device does not appear as a removable drive, consult the manufacturer's support for specific driver or software requirements.
  • Ebda Display: Check battery installation and ensure batteries are not depleted. If the issue persists after replacing batteries, contact customer support.

6. Speċifikazzjonijiet

Traceable Excursion-Trac thermometer with dimensions indicated.

An illustration of the thermometer with its physical dimensions and temperature range.

KaratteristikaDettall
Numru tal-MudellAO-94460-07
Eżattezza±0.25°C
Firxa tat-Temperatura-50°C sa 70°C (-58°F sa 158°F)
Riżoluzzjoni tat-Temperatura0.01°
Tip ta' Sonda1 Bottle Probe
Kapaċità tal-Logging tad-DataUp to 525,600 temperature observations
Tip ta 'WiriLCD, 1/2"H digits
KonnettivitàUSB
Sors tal-Enerġija2 x Batteriji AAA
MaterjalPlastik
Dimensjonijiet (H x W x D)10.79 ċm x 6.98 ċm x 1.9 ċm (madwar 4.25 pulzier x 2.75 pulzier x 0.75 pulzier)
Karatteristiċi SpeċjaliHigh Accuracy, Min/Max Memory, Alarm Function, 3m Micro-Thin Cable, Integrated Stand, Wall Mount, Magnetic Strip

7. Garanzija u Appoġġ

For technical assistance, warranty claims, or further information regarding your Traceable Excursion-Trac Data Logging Thermometer, please contact your supplier or the manufacturer directly. Refer to your purchase documentation for specific warranty terms and contact details.

Dokumenti Relatati - AO-94460-07

Preview Istruzzjonijiet u Speċifikazzjonijiet tat-Termometru li Ma jgħaddix ilma minnu b'Sonda Extra-Long Traċċabbli
Manwal tal-utent u speċifikazzjonijiet għat-Termometru li ma jgħaddix ilma minnu b'Sonda Extra-Long Traċċabbli (Numru tal-Katalgu 6406), inkluż it-tħaddim, l-użu tas-sonda, il-messaġġi fuq il-wiri, is-soluzzjoni tal-problemi, u informazzjoni dwar il-garanzija.
Preview Istruzzjonijiet u Speċifikazzjonijiet tat-Termometru tad-Datalogging Logger-Traċċabbli Logger-Trac
Gwida għall-utent u speċifikazzjonijiet għar-reġistratur elettroniku tad-dejta tat-temperatura Traceable Logger-Trac, li jiddeskrivu l-karatteristiċi, l-operat u s-settings tiegħu għall-monitoraġġ ambjentali.
Preview Termometru tar-Refriġeratur b'Sinjal tar-Radju Traċċabbli 37804-10: Manwal tal-Utent u Istruzzjonijiet
Manwal uffiċjali għall-utent u struzzjonijiet għat-Termometru tar-Refriġeratur b'Sinjal tar-Radju Traceable 37804-10. Tgħallem dwar l-ispeċifikazzjonijiet, is-setup, it-tħaddim, is-soluzzjoni tal-problemi, u l-karatteristiċi għal monitoraġġ preċiż tat-temperatura.
Preview Gwida ta' Bidu Mgħaġġel għal Termometru Diġitali ta' Friġġ/Friżer Traċċabbli
Quick-start guide for the Traceable Refrigerator/Freezer Digital Thermometer (Models 5650, 5651, 5652). Learn how to set up, configure alarms, and understand display messages for accurate temperature monitoring.
Preview Traceable Kangaroo Thermometer Instructions and Specifications
User manual and specifications for the Traceable Kangaroo Thermometer, detailing operation, features like temperature alarms and memory, probe cable management, bench stand usage, battery replacement, and warranty information.
Preview Istruzzjonijiet u Speċifikazzjonijiet tat-Termometru tal-Wiri Jumbo Traċċabbli
This document provides instructions, specifications, troubleshooting, and warranty information for the Traceable Jumbo Display Dial Thermometer, model 92-4049-00. It details temperature range, accuracy, operation, battery replacement, and contact details for service.