Elitech Loget 260-TH

Elitech Loget 260-TH 4G Real-time Temperature Humidity Data Logger User Manual

1. Introduzzjoni

This manual provides detailed instructions for the setup, operation, and maintenance of the Elitech Loget 260-TH 4G Real-time Temperature Humidity Data Logger. This device is designed for monitoring temperature, humidity, light, shock, and location in various cold chain applications, providing real-time data transmission via 4G network.

1.1. Kontenut tal-Pakkett

  • Elitech Loget 260-TH Data Logger (Reusable version)
  • Built-in 4G SIM Card
  • Manwal għall-Utent
  • Kejbil USB Type-C

2. Prodott Aktarview

The Loget 260-TH is a multi-sensor data logger equipped with a display and control buttons for easy interaction. It features internal sensors for temperature, humidity, light, and shock, along with LBS (Location-Based Service) for location tracking.

Elitech Loget 260-TH Data Logger with labeled parts

Figure 2.1: Elitech Loget 260-TH Data Logger with numbered components.

2.1. Identifikazzjoni tal-Komponent

  1. Skrin tad-displej LCD: Shows current readings, status, and alerts.
  2. Dawl Indikatur LED: Provides visual status updates (e.g., OK, Alarm).
  3. Activate/Airplane Mode Button: Used to activate the device or toggle airplane mode.
  4. Sensor Intern: Measures ambient temperature and humidity.
  5. Back Hanging Hole: For mounting or securing the device.
  6. Buttuna Start / Stop: Initiates or terminates data logging.
  7. Numru tas-serje: Unique identifier for the device.
  8. Sensor tad-Dawl: Detects ambient light levels.
  9. Data Transmission Indicator: Shows network activity and data upload status.

2.2. Karatteristiċi ewlenin

  • Double Data Security: Features offline storage for up to 100,000 points to prevent data loss and supports shadow data recording for continuous monitoring even if logging is mistakenly stopped.
  • Multi-Source Sensing: Monitors internal temperature (-30~60℃), humidity (0~100%RH), light (0~52000Lux), shock (0g~16g), and location (LBS). Optional external sensors for pH value or CO2 are available separately.
  • Remote Monitoring via APP/Web: Real-time data is uploaded to the Elitech iCold Cloud platform via a built-in 4G SIM card. Upload intervals are configurable from 1 minute to 24 hours.
  • Comprehensive Alarm System: Cloud-based alarms can be received via Elitech iCold APP, SMS, Email, or the web platform. The device also provides local sound, screen, and indicator light alarms for offline events.
  • Auto Flight Mode & Electronic Fence: Complies with Do160 for aviation safety. Flight mode can be activated manually, scheduled, or automatically via an electronic fence (custom area activation).
  • iCold Platform: A cloud-based platform compatible with RCW series products for real-time monitoring, automatic alerts, online data analysis, and management. It complies with FDA CFR 21 Part 11 requirements and supports iOS and Android apps.

3. Setup

3.1. Iċċarġjar Inizjali

Before first use, connect the Loget 260-TH to a power source using the provided USB Type-C cable and a standard USB charger (not included) to ensure the internal battery is fully charged. The battery indicator on the LCD will show charging status.

3.2. Device Activation and Platform Connection

  1. Qawwa Mixgħul: Press and hold the 'Start/Stop' button for a few seconds until the device powers on and the LCD screen illuminates.
  2. Konnessjoni tan-Netwerk: The built-in 4G SIM card will automatically attempt to connect to the network. The signal strength indicator on the LCD will show connection status.
  3. iCold Account Setup:
    • Download the Elitech iCold APP from your mobile app store or visit the Elitech iCold web pjattaforma (http://new.i-elitech.com).
    • Irreġistra għal kont ġdid jew idħol jekk diġà għandek wieħed.
    • Add your Loget 260-TH device to your account using the serial number found on the device (refer to Figure 2.1, item 7).
  4. Konfigurazzjoni: Once added, you can configure logging parameters such as upload interval, alarm thresholds, and sensor settings via the iCold platform.

4. Istruzzjonijiet Operattivi

4.1. Starting and Stopping Logging

  • Ibda Logging: Press and hold the 'Start/Stop' button until the logging indicator appears on the LCD. The device will begin recording data according to the configured settings.
  • Stop Logging: Press and hold the 'Start/Stop' button again until the logging indicator disappears. Data logging will cease.

4.2. Modalità Ajruplan

Airplane mode disables all wireless communication (4G) to comply with aviation regulations. Data logging continues internally.

Elitech Loget 260-TH Data Logger displaying Flight Mode feature

Figure 4.1: Loget 260-TH illustrating Flight Mode activation methods.

  • Attivazzjoni manwali: Press the 'Activate/Airplane Mode' button (Figure 2.1, item 3) to toggle airplane mode on or off.
  • Scheduled Activation: Configure specific times for airplane mode activation via the iCold platform.
  • Electronic Fence Activation: Set up a custom geographical area in the iCold platform. The device will automatically enter airplane mode upon entering this area and exit upon leaving.

4.3. Data Access and Alarms

Elitech Loget 260-TH Data Logger next to a smartphone displaying the iCold app interface with data graphs

Figure 4.2: Loget 260-TH data displayed on the Elitech iCold mobile application.

  • Dejta f'ħin reali: View live temperature, humidity, light, shock, and location data on the Elitech iCold APP or web pjattaforma.
  • Dejta Storika: Access and analyze historical data, generate reports (PDF/CSV), and track routes through the iCold platform.
  • Notifiki ta' Allarm: Receive instant alerts via APP, SMS, or Email when configured parameters exceed set thresholds. The device also provides local visual and audible alarms.
Elitech Loget 260-TH Data Logger with a laptop showing PDF and CSV report export options from the iCold platform

Figure 4.3: Elitech iCold platform demonstrating PDF and CSV report export functionality.

5. Manutenzjoni

5.1. Kura tal-batterija

  • Recharge the device regularly, especially if it will be stored for an extended period.
  • Avoid exposing the device to extreme temperatures during charging or storage, as this can degrade battery life.

5.2. Tindif

  • Imsaħ l-apparat b'ċarruta ratba u niexfa.
  • Do not use abrasive cleaners or solvents, as these can damage the casing jew sensuri.

5.3. Ħażna

  • Aħżen l-apparat f'post frisk u niexef 'il bogħod mix-xemx diretta.
  • Kun żgur li l-batterija tkun parzjalment iċċarġjata (madwar 50%) qabel ma taħżenha għal żmien twil.

6 Issolvi l-problemi

6.1. L-Apparat Mhux Qed Jixgħel

  • Ensure the device is fully charged. Connect it to a power source using the USB Type-C cable.
  • Verify that the 'Start/Stop' button is pressed and held for the required duration.

6.2. No 4G Network Connection

  • Check the signal strength indicator on the LCD. If weak, move to an area with better network coverage.
  • Ensure airplane mode is not active.
  • Contact Elitech support if the issue persists, as the built-in SIM card may require troubleshooting.

6.3. Data Not Uploading to iCold Platform

  • Confirm the device has a stable 4G connection.
  • Verify that the device is correctly added and configured in your iCold account.
  • Check the upload interval settings in the iCold platform.

6.4. Qari Mhux Preċiż

  • Ensure the sensors are not obstructed or exposed to direct heat/cold sources that do not reflect the ambient environment.
  • Allow the device to stabilize in a new environment for a few minutes before taking critical readings.

7. Speċifikazzjonijiet

ParametruValur
Numru tal-MudellUS-LogEt260-TH-10PACK
Temperature Range (Internal)-30 ℃ sa 60 ℃ (-22 ℉ sa 140 ℉)
Humidity Range (Internal)0% sa 100% RH
Medda tas-Sensor tad-Dawl0 sa 52000 Lux
Shock Sensor Range0g sa 16g
Traċċar tal-PostLBS (Location-Based Service)
Kapaċità tal-Ħażna tad-Dejta100,000 points (offline)
Konnettività4G (Built-in SIM Card)
Intervall tat-TlugħConfigurable (1 minute to 24 hours)
Tip ta 'batterijaLithium Ion (inkluż)
InterfaceUSB Tip-Ċ
KonformitàDo160 (Aviation Safety), FDA CFR 21 Part 11

8. Garanzija u Appoġġ

For warranty information, technical support, or service inquiries, please contact Elitech Technology Inc. directly. Refer to the official Elitech website or the contact information provided with your purchase for the most up-to-date support details.

Pjattaforma Elitech iCold: http://new.i-elitech.com

Dokumenti Relatati - Loget 260-TH

Preview Manwal tal-Istruzzjonijiet tas-Serje Elitech LogEt 260 - Loggers tad-Data tat-Temperatura, tad-Dawl, u tal-Vibrazzjoni
Manwal ta' struzzjonijiet komprensiv għad-data loggers tas-serje Elitech LogEt 260, li jkopri s-sigurtà, il-karatteristiċi tal-prodott, l-għażla, il-parametri tekniċi, it-tħaddim, u l-indikaturi LED. Jinkludi t-temperatura, id-dawl, il-monitoraġġ tal-vibrazzjoni, u l-konnettività 4G.
Preview Manwal tal-Utent tad-Data Logger tas-Serje Elitech LogEt 8 - Monitoraġġ tat-Temperatura u l-Umdità
Manwal komprensiv għall-utent għad-data loggers Elitech LogEt tas-Serje 8, li jagħti dettalji dwar l-ispeċifikazzjonijiet, it-tħaddim, l-installazzjoni, u s-soluzzjoni tal-problemi għall-monitoraġġ tat-temperatura u l-umdità fil-loġistika tal-katina tal-kesħa.
Preview Elitech LogEt 5 Series User Manual: Temperature and Humidity Data Loggers
Comprehensive user manual for the Elitech LogEt 5 Series temperature and humidity data loggers. Covers overview, model selection, specifications, operation, status indication, battery replacement, and default configurations.
Preview Elitech LogEt 1 Series User Manual: Temperature and Humidity Data Loggers
Comprehensive user manual for the Elitech LogEt 1 series of single-use data loggers, covering LogEt 1 (temperature), LogEt 1TH (temperature-humidity), and LogEt 1 Bio (high accuracy temperature). Includes specifications, operation, status indication, and warnings.
Preview Elitech LogEt 1 Series Single-Use PDF Data Logger User Manual
User manual for the Elitech LogEt 1, LogEt 1TH, and LogEt 1Bio single-use PDF data loggers, covering appearance, technical specifications, indication instructions, and operation.
Preview Elitech LogEt 5 Series Data Logger Specifications and User Manual
Comprehensive specifications, features, and operating instructions for the Elitech LogEt 5 series of temperature and humidity data loggers, designed for cold chain monitoring.