sinocare Safe AQ UG 50 kit

Sinocare Safe AQ UG 2-in-1 Uric Acid & Blood Glucose Test Kit

Model: Safe AQ UG 50 kit

Brand: Sinocare

1. Introduzzjoni

The Sinocare Safe AQ UG Multifunctional Monitor is a comprehensive 2-in-1 system designed for convenient and accurate self-testing of both blood glucose and uric acid levels. This kit provides essential tools for individuals managing diabetes and gout, enabling regular monitoring from the comfort of their home.

The device features a user-friendly design, quick test times, and requires minimal blood samples. It is engineered for precision and ease of use, making it a reliable choice for personal health management.

Kontenut tal-Kit:

Sinocare Safe AQ UG 2-in-1 Monitor Kit
Figure 1: Complete Sinocare Safe AQ UG 2-in-1 Monitor Kit including the monitor, test strips, lancing devices, and carrying case.

2. Setup

2.1 Spakkjar u Spezzjoni

Carefully unpack all components from the kit. Verify that all items listed in the "Kit Contents" section are present and undamaged. If any items are missing or damaged, please contact Sinocare customer service immediately.

2.2 Installazzjoni tal-batterija

The Sinocare Safe AQ UG monitor requires batteries for operation. Ensure you have two AAA alkaline batteries (included in some kits, or purchase separately if not). Locate the battery compartment on the back of the monitor, open the cover, insert the batteries according to the polarity indicators (+/-), and close the cover securely.

2.3 Meter Components Overview

Familiarize yourself with the different parts of your Sinocare Safe AQ UG monitor:

Sinocare Safe AQ UG Meter Description
Figure 2: Diagram illustrating the various components and display elements of the Sinocare Safe AQ UG monitor, including the uric acid and blood glucose test strip slots, display areas, and control buttons.

2.4 Coding the Uric Acid Test Strips

The uric acid test strips require coding for accurate results. Each new vial of uric acid test strips comes with a corresponding code chip. It is crucial to insert this code chip into the meter every time you open a new vial of uric acid test strips. Blood glucose test strips do not require coding.

Smart Coding Technique for Uric Acid Strips
Figure 3: Illustration of the smart coding technique for uric acid test strips. The image shows how to insert the code chip into the meter, which is required for accurate uric acid measurements with each new vial of strips.
  1. Locate the code chip provided with your new vial of uric acid test strips.
  2. With the meter off, insert the code chip into the designated slot on the side of the meter.
  3. The meter will automatically recognize the code. Once the code is set, you can remove the chip.
  4. Nota Importanti: Always ensure the meter is coded correctly for the uric acid strips you are using. Incorrect coding can lead to inaccurate results.

3. Istruzzjonijiet Operattivi

3.1 Preparing for a Test

3.2 Twettiq ta' Test tal-Glukożju fid-Demm

Blood Glucose Test Method Steps
Figure 4: Step-by-step guide for performing a blood glucose test using the Sinocare Safe AQ UG monitor, showing strip insertion, lancing, blood application, and result display.
  1. Insert a blood glucose test strip into the blood glucose test strip slot (G) of the meter. The meter will turn on automatically and display a blood drop symbol, indicating it's ready for a blood sample.
  2. Use the lancing pen to prick the side of your fingertip to obtain a blood drop.
  3. Gently touch the tip of the blood glucose test strip to the blood drop. The strip will draw the blood sample into the reaction area. Do not apply blood to the top of the strip.
  4. The meter will begin counting down. Your blood glucose result will appear on the display in approximately 5 seconds.
  5. Record your result and dispose of the used test strip and lancing device safely.

3.3 Performing a Uric Acid Test

Uric Acid and Blood Glucose Test Slot Differences
Figure 5: Comparison of the G (Glucose) and U (Uric Acid) slots on the Sinocare Safe AQ UG monitor, highlighting the different blood application methods for each strip type (top suction for glucose, side suction for uric acid).
  1. Ensure the meter has been correctly coded for the uric acid test strips you are using (refer to Section 2.4).
  2. Insert a uric acid test strip into the uric acid test strip slot (U) of the meter. The meter will turn on automatically and display a blood drop symbol.
  3. Use the lancing pen to prick the side of your fingertip to obtain a blood drop.
  4. Gently touch the side suction port of the uric acid test strip to the blood drop. The strip will draw the blood sample into the reaction area.
  5. The meter will begin counting down. Your uric acid result will appear on the display in approximately 25 seconds.
  6. Record your result and dispose of the used test strip and lancing device safely.

3.4 Important Notes for Accurate Results

4. Manutenzjoni u Ħażna

4.1 Tindif tal-Miter

Clean the exterior of the meter regularly with a soft, damp cloth. Do not use harsh chemicals, abrasive cleaners, or immerse the meter in water. Ensure no liquid enters the test strip slots or battery compartment.

4.2 Ħażna xierqa

4.3 Sostituzzjoni tal-batterija

When the battery indicator appears on the display, replace the batteries promptly to ensure continued accurate operation. Follow the instructions in Section 2.2 for battery installation.

5 Issolvi l-problemi

If you encounter issues with your Sinocare Safe AQ UG monitor, please refer to the following common problems and solutions:

ProblemaKawża PossibbliSoluzzjoni
Il-miter ma jixgħelx.Batteriji mejta jew installati ħażin.Check battery polarity. Replace batteries if needed.
Inaccurate Uric Acid readings.Incorrect code chip inserted; expired or damaged strips; insufficient blood sample; improper blood application (not side suction).Ensure the correct code chip for the current vial is inserted. Check strip expiry date. Ensure sufficient blood is applied to the side suction port. Refer to Section 3.3.
Messaġġ ta' żball fuq il-wiri.Refer to the specific error code in the full user manual (if available) or contact customer service. Common errors relate to strip insertion or sample applikazzjoni.Re-read instructions for strip insertion and blood application. Try a new strip.
No blood drawn by strip.Demm insuffiċjenti sample; strip not correctly inserted; strip damaged.Ensure a sufficient blood drop is formed. Re-insert strip firmly. Use a new strip.

If the problem persists after attempting these solutions, please contact Sinocare customer service for further assistance.

6. Speċifikazzjonijiet

KaratteristikaDettall
Isem tal-ProdottSinocare Safe AQ UG Multifunctional Monitor
Numru tal-MudellSafe AQ UG 50 kit
Tip ta' KejlBlood Glucose & Uric Acid
Blood Glucose Test TimeAppross. 5 sekonda
Uric Acid Test TimeAppross. 25 sekonda
Blood Glucose Sample Volum0.6 micro liters
Uric Acid Sample Volum3 micro liters
Kapaċità tal-Memorja500 Blood Glucose results, 100 Uric Acid results
Sors tal-EnerġijaAlkaline Batteries (Type not specified, usually AAA)
Unità ta' Kejlmmol/L (UK standard)
Piż330 g (madwar)
Manifattursinocare
Sinocare Safe AQ UG Memory Capacity
Figure 6: Display illustrating the large memory capacity of the Sinocare Safe AQ UG monitor, capable of storing 500 blood glucose results and 100 uric acid results.

7. Garanzija u Appoġġ

7.1 Informazzjoni dwar Garanzija

Sinocare products are manufactured to high-quality standards. For specific warranty terms and conditions, please refer to the warranty card included with your product or visit the official Sinocare websit. Żomm l-irċevuta tax-xiri tiegħek bħala prova tax-xiri.

7.2 Appoġġ għall-Klijent

If you have any questions, require technical assistance, or encounter any issues not covered in this manual, please contact Sinocare customer service. You can typically find contact information on the product packaging, the official Sinocare webis-sit, jew permezz tal-punt tax-xiri tiegħek.

When contacting support, please have your product model number (Safe AQ UG 50 kit) and purchase details ready to facilitate quicker service.

Dokumenti Relatati - Safe AQ UG 50 kit

Preview Manwal tal-Utent tal-Istrixxi tat-Test tal-Glukożju fid-Demm Sinocare Safe AQ UG
Manwal tal-utent għall-Istrixxi tat-Test tal-Glukożju fid-Demm Sinocare Safe AQ UG, li jiddeskrivi l-użu maħsub, il-kompatibilità mal-monitor Safe AQ UG, il-ħażna, l-immaniġġjar, u l-proċeduri tal-ittestjar għal monitoraġġ preċiż tal-glukożju fid-demm.
Preview Gwida Rapida ta' Sinocare Safe AQ Voice: Monitoraġġ Faċli tal-Glukożju fid-Demm
Gwida konċiża għall-użu tal-miter tal-glukożju fid-demm Sinocare Safe AQ Voice għal ittestjar rapidu u preċiż taz-zokkor fid-demm. Tgħallem kif tipprepara l-materjali, twettaq it-test, u tinterpreta r-riżultati.
Preview Sinocare Safe AQ UG Blood Glucose and Uric Acid Meter User Manual
Comprehensive user manual for the Sinocare Safe AQ UG Blood Glucose and Uric Acid Monitoring System, detailing setup, operation, testing procedures, and troubleshooting for accurate health monitoring.
Preview Sinocare Safe AQ pro I Blood Glucose Test Strip Package Insert
Official package insert for Sinocare Safe AQ pro I Blood Glucose Test Strips, providing detailed information on intended use, testing procedures, results interpretation, storage, and performance characteristics for diabetes management.
Preview Strixxi tat-Test tal-Glukożju fid-Demm Sinocare Safe-Accu 2: Gwida għall-Utent u Speċifikazzjonijiet
Fuljett komprensiv fil-pakkett għall-Istrixxi tat-Test tal-Glukożju fid-Demm Sinocare Safe-Accu 2, li jkopri l-użu maħsub, il-prinċipji tat-test, il-prestazzjoni, u twissijiet importanti għall-awto-ittestjar.
Preview Manwal tal-Utent tal-Miter tal-Glukożju fid-Demm Safe AQ Smart, Safe AQ Voice, Safe AQ Air
Manwal komprensiv għall-utent għas-sistemi ta' monitoraġġ tal-glukożju fid-demm Sinocare Safe AQ Smart, Safe AQ Voice, u Safe AQ Air. Tgħallem dwar l-użu maħsub, l-informazzjoni dwar is-sigurtà, il-prinċipji tat-test, it-tħaddim, is-soluzzjoni tal-problemi, u l-manutenzjoni.