Introduzzjoni
This manual provides comprehensive instructions for the installation, operation, and maintenance of your ECOELER YWT102 Countdown Timer Switch. This in-wall timer switch is designed to automatically turn off connected loads such as lights, ceiling fans, bathroom fans, and heaters after a preset time, contributing to energy savings and convenience. It features multiple preset countdown options and a manual override function.

Image: The ECOELER Countdown Timer Switch in Ivory, shown as a 2-pack.
Karatteristiċi tal-Prodott
- 8 Pre-Set Options: Offers countdown settings of 1 minute, 5 minutes, 10 minutes, 15 minutes, 30 minutes, 60 minutes, 2 hours, or 4 hours.
- Override manwali: Allows instant ON/OFF control, overriding any active countdown.
- Iffrankar tal-Enerġija: Automatically turns off loads, preventing accidental energy waste. Ideal for lights, ceiling fans, bathroom fans, and heaters.
- Operazzjoni sempliċi: Features Countdown mode and Constant On mode. Select time with a button press; hold ON/OFF for 5 seconds to activate Constant On.
- Indikatur LED: An always-on LED light makes the switch easy to locate in low-light conditions.
- Applikazzjoni wiesgħa: Suitable for bathrooms, closets, pantries, garages, laundry rooms, spas, and enclosed patios.
- Sikur u Affidabbli: ETL listed, supporting LED/CFL, Incandescent (800W), Fluorescent (1200VA) light bulbs, and motors (1/2 HP).

Immaġni: Dettaljata view of the ECOELER Countdown Timer Switch buttons and LED indicator labels, highlighting its features.
Kontenut tal-Pakkett
Upon opening your ECOELER Countdown Timer Switch package, you should find the following items:
- ECOELER YWT102 Countdown Timer Switch
- Matching Wall Plate
- Wajer Ġewż
- Manwal tal-Istruzzjonijiet għall-Installazzjoni

Image: The ECOELER Countdown Timer Switch, wire nuts, and face plate, along with product dimensions.
Informazzjoni dwar is-Sigurtà
TWISSIJA: To prevent serious injury or death from electric shock, always turn OFF the power at the circuit breaker or fuse box before wiring. This device is intended for installation in accordance with the National Electric Code and local regulations. Use copper wires only. If you are unsure about any part of these instructions, consult a qualified electrician.
Speċifikazzjonijiet
| Speċifikazzjoni | Valur |
|---|---|
| Brand | ECOELER |
| Numru tal-Mudell | YWT102 |
| Kulur | Avorju |
| Dimensjonijiet tal-Prodott | 4.19 x 3.71 x 11.99 ċm |
| Qawwa/Wattage | 1800 watt |
| Materjal | Copper, Metal, Polycarbonate |
| Piż tal-oġġett | 136 g |
| Mod ta' Operazzjoni | ON-OFF |
| Klassifikazzjoni kurrenti | 15 Amps |
| Vol Operattivtage | 120 Volts (AC) |
| Tip ta' Kuntatt | Normalment Miftuħ |
| Tip ta' Swiċċ | Imbotta Buttuna |
| Terminal | Ċomb tal-wajers |
Installazzjoni
Follow these steps carefully to install your ECOELER Countdown Timer Switch. If you are not comfortable performing electrical work, please consult a qualified electrician.
Qabel l-Installazzjoni
- Itfi l-Enerġija: Locate your circuit breaker panel and turn off the power to the switch box where you will be installing the timer. Verify that the power is off using a voltagtester.
- Neħħi Swiċċ Eżistenti: Carefully remove the screws holding the existing wall plate and switch. Gently pull the switch out of the wall box.
- Identifika l-Wajers: Identify the wires connected to your existing switch. Typically, you will find:
- Hot Wire: Normalment iswed, iġib l-enerġija mis-circuit breaker.
- Wajer tat-Tagħbija: Usually black or red, carries power to the light/fan.
- Wajer newtrali: Normalment abjad. A neutral wire is required for this timer switch.
- Wajer tal-art: Normalment ram aħdar jew mikxuf.
Konnessjonijiet tal-Wiring
Connect the wires from the wall box to the ECOELER Countdown Timer Switch as follows:

Image: Wiring diagram for the ECOELER Countdown Timer Switch, illustrating connections for Load (Red), Hot (Black), Ground (Green), and Neutral (White) wires. Note: Neutral Wire Must Be Required.
- Qabbad il- Wajer aħmar from the timer to the Wajer tat-tagħbija from the wall box using a wire nut.
- Qabbad il- Wajer iswed from the timer to the Wajer sħun from the wall box using a wire nut.
- Qabbad il- Wajer abjad from the timer to the Wajer newtrali from the wall box using a wire nut.
- Qabbad il- Wajer aħdar from the timer to the Wajer mitħun from the wall box using a wire nut.
Post-Installazzjoni
- Carefully push all wires back into the wall box.
- Secure the timer switch to the wall box with the provided screws.
- Attach the new wall plate over the timer switch.
- Irrestawra l-Enerġija: Return to your circuit breaker panel and turn the power back ON.
Istruzzjonijiet Operattivi
The ECOELER Countdown Timer Switch offers two primary operating modes: Countdown Mode and Constant On Mode.
Mod ta 'Countdown
To activate a countdown:
- Press the desired time button (1 Min, 5 Min, 10 Min, 15 Min, 30 Min, 60 Min, 2 Hour, or 4 Hour).
- The corresponding LED indicator will illuminate, and the countdown will begin.
- The connected load (light, fan, etc.) will turn off automatically once the selected time expires.
- To cancel a countdown manually, press the large ON/OFF button at the bottom.
Constant On Mode (Manual Override)
To keep the connected load continuously ON, bypassing the timer function:
- Press and hold the large ON/OFF button at the bottom for more than 5 seconds.
- The load will remain ON until the ON/OFF button is pressed again to turn it off.

Image: The ECOELER Countdown Timer Switch with its LED indicator illuminated, making it visible in a dark environment.
Manutenzjoni
The ECOELER Countdown Timer Switch requires minimal maintenance. To ensure optimal performance and longevity:
- Keep the switch and wall plate clean by wiping with a soft, damp drapp. Evita prodotti tat-tindif jew solventi li joborxu.
- Kun żgur li s-swiċċ ma jkunx espost għal umdità eċċessiva jew temperaturi estremi.
- Periodically check the connections for any signs of loosening, though this should only be done with the power turned off at the circuit breaker.
Issolvi l-problemi
If you encounter issues with your ECOELER Countdown Timer Switch, consider the following:
- Is-Swiċċ Mhux Jirrispondi: Ensure the power is ON at the circuit breaker. Check all wire connections for tightness.
- Load Not Turning Off: Verify that the switch is not in Constant On mode (manual override). If it is, press the ON/OFF button to turn it off.
- Indikatur LED ma jixgħelx: Check power supply and connections. If the switch is functioning otherwise, the LED might be faulty, but this is rare.
- Operazzjoni intermittenti: Ensure all wire connections are secure. Loose connections can cause inconsistent performance.
Jekk il-problemi jippersistu wara li tiċċekkja dawn il-punti, jekk jogħġbok ikkuntattja l-appoġġ għall-klijenti.
Garanzija u Appoġġ
The ECOELER Countdown Timer Switch comes with a garanzija ta 'sena. For any questions, technical assistance, or warranty claims, please contact ECOELER customer support. You can reach us via email at SUPPORTS@ECOELER.COM. We aim to respond to all inquiries within 24 hours.
Manufacturer: ECOELER ELECTRIC INC