Istruzzjonijiet Importanti dwar is-Sigurtà
Please read all instructions carefully before installation and operation. Keep this manual for future reference.
- Installazzjoni Professjonali Rakkomandata: For optimal performance and safety, professional installation is strongly advised.
- Pożizzjoni Wieqfa: Ensure the unit remains in an upright position for at least 24 hours prior to use to allow refrigerants to settle.
- Sigurtà Elettrika: Connect the unit to a properly grounded electrical outlet with the correct voltage (115V). Do not use extension cords.
- Approvazzjonijiet: Żomm spazji adegwati madwar l-unitajiet kemm ta' ġewwa kif ukoll ta' barra għal fluss tal-arja u manutenzjoni xierqa.
- Tfal u Pets: Żomm it-tfal u l-annimali domestiċi 'l bogħod mill-unità waqt it-tħaddim u l-manutenzjoni.
- Materjali li jaqbdu: Do not store or use flammable liquids or gases near the air conditioner.
Prodott Overview
The Euker 9,000 BTU Mini Split Air Conditioner is a versatile system designed for efficient cooling and heating of spaces up to 450 sq.ft. It features smart control options, energy-saving technology, and multiple operating modes.
Komponenti tal-Prodott
Your Euker Mini Split AC system includes the following main components and accessories:

Figura 1: Prodott ewlieni view showing the indoor unit (wall mount air handler), outdoor unit (condenser), remote control, and various installation accessories including copper line set, drainage extension, and communication wires.

Figura 2: Dettaljati view of the indoor and outdoor unit dimensions, along with the pre-flared and insulated copper line set (16.4 FT), drainage extension with small accessories, and communication wires.
Setup u Installazzjoni
Proper installation is crucial for the efficient and safe operation of your mini split system. While this section provides general guidelines, professional installation is highly recommended.
Kontrolli ta' Qabel l-Installazzjoni
- Verify that the chosen installation location for both indoor and outdoor units meets clearance requirements and can support the unit's weight.
- Ensure the electrical supply matches the unit's voltage (115V) and is properly grounded.
- Confirm all included components and accessories are present as shown in Figure 1 and Figure 2.
Komponenti li jgħaqqdu
- Linji tar-refriġerant: Connect the pre-flared and insulated copper line set (16.4 FT) between the indoor and outdoor units. Ensure connections are tight to prevent leaks.
- Drenaġġ: Install the drainage extension to the indoor unit to ensure proper condensate removal.
- Wiring Elettriku: Connect the communication wires between the indoor and outdoor units, and the main power supply to the outdoor unit, following local electrical codes and the wiring diagram provided in the full installation manual.
Istruzzjonijiet Operattivi
Your Euker Mini Split AC offers multiple ways to control your comfort and a variety of operating modes.
Metodi ta' Kontroll
- Kontroll mill-bogħod: Use the included backlit LCD remote controller for direct control of all functions.
- Kontroll WiFi: Download the dedicated app to control your unit remotely via WiFi from your smartphone.
- Kontroll tal-Vuċi bl-AI: The system supports AI voice control for convenient hands-free operation.

Figura 3: The Euker Mini Split AC can be controlled via the included remote control, a smartphone app for WiFi control, and supports AI voice control for convenience.
Modi Operattivi
The unit offers five primary operating modes to suit your climate control needs:
- Modalità Kessaħ: Provides cooling down to 60°F.
- Modalità tas-Sħana: Provides heating up to 89°F, even in low temperatures as low as -4°F (-20°C).
- Modalità Fan: Circulates air without heating or cooling. Offers four fan speeds.
- Modalità Niexfa (Deumidifikazzjoni): Removes excess moisture from the air, with a capacity of 48 Pints/day.
- Modalità Awtomatika: Automatically selects the appropriate mode (Cool, Heat, or Fan) based on the ambient temperature and desired setting.

Figura 4: The Euker Mini Split AC offers 4-in-1 functionality, including Cool, Heat, Fan, and Dry (dehumidification) modes.

Figura 5: The unit provides fast cooling to 60°F and fast heating to 89°F, ensuring rapid comfort.
Karatteristiċi Speċjali
- Modalità Sleep: Adjusts temperature and fan speed for comfortable sleep, ensuring ultra-silent operation at only 27 dB.
- Modalità ECO: Optimizes energy consumption for greater efficiency.
- IFEEL Function: The remote control senses the temperature around it and transmits the signal back to the indoor unit, allowing the unit to adjust airflow for localized comfort.
- Funzjoni Turbo: Jipprovdi tkessiħ jew tisħin rapidu biex jilħaq malajr it-temperatura mixtieqa.
- Awto-Tindif: The indoor unit automatically cleans its interior to maintain fresh, clean air.
- Defrost Awtomatiku: The outdoor unit features an auto-defrost function that activates at low temperatures (-4°F/-20°C) to prevent ice buildup and enhance efficiency.

Figura 6: The Euker Mini Split AC operates quietly at 27 dB in sleep mode, providing a peaceful environment and gentle airflow.

Figura 7: The 19 SEER rating indicates high energy efficiency, leading to significant energy and cost savings.
Manutenzjoni
Regular maintenance ensures the longevity and efficient operation of your Euker Mini Split AC.
Kura u Tindif
- Tindif tal-filtru: The unit features a washable filter. Regularly remove and clean the filter to maintain optimal airflow and air quality. Refer to the full manual for detailed instructions on filter removal and cleaning frequency.
- Funzjoni ta' Awto-Tindif: Utilize the self-cleaning function to automatically clean the indoor unit's interior, preventing mold and bacteria buildup.
- Tindif ta' barra: Wipe the exterior of both indoor and outdoor units with a soft, damp drapp. Tużax kimiċi ħarxa jew tindif li joborxu.
- Unità ta 'barra: Keep the area around the outdoor condenser clear of debris, leaves, and other obstructions to ensure proper airflow.
Issolvi l-problemi
Qabel ma tikkuntattja l-appoġġ għall-klijenti, jekk jogħġbok irreferi għat-tabella li ġejja għal kwistjonijiet komuni u s-soluzzjonijiet potenzjali tagħhom.
| Problema | Kawża Possibbli | Soluzzjoni |
|---|---|---|
| L-unità ma tixgħel | Ebda provvista tal-enerġija; Batteriji tal-kontroll remot mejta; Interruttur taċ-ċirkwit. | Iċċekkja l-konnessjoni tal-enerġija; Ibdel il-batteriji tar-remote; Irrisettja ċ-ċirkwit interruttur. |
| Tkessiħ/tisħin insuffiċjenti | Dirty air filter; Obstruction to airflow; Incorrect mode selected; Room size too large. | Clean or replace air filter; Remove obstructions; Select correct mode; Ensure unit capacity matches room size. |
| Ħoss mhux tas-soltu | Loose parts; Unit not level; Debris in fan. | Check for loose components; Ensure unit is level; Inspect for and remove debris. |
| Tnixxija ta' ilma mill-unità ta' ġewwa | Pajp tad-drenaġġ imblukkat; Installazzjoni ħażina. | Clear drain hose; Contact professional installer for inspection. |
| Il-kontroll mill-bogħod ma jaħdimx | Batteriji mejta jew imdaħħla ħażin; Ostruzzjoni bejn ir-remote u l-unità. | Ibdel il-batteriji; Kun żgur li l-linja tal-vista hija ċara għar-riċevitur tal-unità ta' ġewwa. |
Speċifikazzjonijiet Tekniċi
| Karatteristika | Speċifikazzjoni |
|---|---|
| Brand | Euker |
| Qawwa tat-tkessiħ | 9,000 Unità Termali Brittanika (BTU) |
| Proporzjon tal-Effiċjenza Enerġetika Staġjonali (SEER) | 19 |
| Voltage | 115 Volts |
| Kapaċità ta 'Deumidifikazzjoni | 48 Pinta/jum |
| Dimensjonijiet tal-Unità ta' Ġewwa (W x H x D) | 31.92" x 8.07" x 11.49" |
| Dimensjonijiet tal-Unità ta' Barra (W x H x D) | 28.14" x 19.61" x 11.42" |
| Livell tal-Istorbju (Ġewwa) | Sa 27 dB |
| Operating Temperature Range (Cooling) | 60°F sa 89°F |
| Operating Temperature Range (Heating) | 60°F to 89°F (down to -4°F / -20°C outdoor) |
| Karatteristiċi Speċjali | Remote Controlled, WiFi Control, AI Voice Control, Self-Cleaning, Auto Defrost, Sleep Mode, ECO Mode, IFEEL, Turbo |
| Kulur | Abjad |
Garanzija u Appoġġ
Euker is dedicated to providing the best shopping experience and stands firmly behind its product. While specific warranty details are provided at the time of purchase, general support is available for any questions or concerns.
For technical assistance, troubleshooting beyond this manual, or warranty claims, please refer to the contact information provided with your purchase documentation or visit the official Euker websit.
Professional installation is recommended to ensure proper operation and to validate any applicable warranties.