LIORQUE TCS0202A

LIORQUE Carbon Monoxide Detector (Model TCS0202A)

Manwal għall-Utent

1. Introduzzjoni

The LIORQUE Carbon Monoxide (CO) Detector, Model TCS0202A, is designed to provide continuous monitoring for carbon monoxide gas in your home. Equipped with an advanced electrochemical sensor and a 10-year integrated battery, this device offers reliable protection against the dangers of CO poisoning. It is certified and compliant with European standard EN50291.

Carbon monoxide is a colorless, odorless, and tasteless gas that can be fatal. This detector is an essential safety device for any household, especially those with fuel-burning appliances such as furnaces, water heaters, fireplaces, and gas stoves.

LIORQUE Carbon Monoxide Detector, front view

Stampa 1: Quddiem view of the LIORQUE Carbon Monoxide Detector showing the display, test button, and LED indicators.

2. Informazzjoni dwar is-Sigurtà u Twissijiet Importanti

Please read all instructions carefully before installation and operation. Failure to follow these instructions may result in improper operation of the detector and could lead to serious injury or death.

Linji Gwida Ġenerali dwar is-Sigurtà:

  • This device is designed to detect carbon monoxide gas from any source of combustion. It is not designed to detect smoke, fire, or other gases.
  • The detector should be tested regularly to ensure proper function.
  • Do not paint the detector. Paint can clog the openings and interfere with the sensor's ability to detect CO.
  • Do not block the ventilation openings of the detector.
  • In case of an alarm, evacuate the premises immediately and contact emergency services.

Restrizzjonijiet ta' Installazzjoni:

To ensure optimal performance and avoid false alarms or impaired detection, do not install the CO detector in the following locations:

  • Directly above kitchen fumes or cooking appliances.
  • In garages, as vehicle exhaust contains CO and can cause false alarms.
  • In bathrooms, saunas, or steam rooms, due to high humidity and temperature fluctuations.
  • In areas with extreme temperatures (below 0°C or above 45°C).
  • In dusty, dirty, or greasy areas.
  • In direct sunlight or near heat sources.
  • In areas where it might be obstructed by furniture or curtains.

3. Setup u Installazzjoni

The LIORQUE CO Detector is designed for easy installation. It comes with the necessary mounting accessories.

Postijiet Rakkomandati għall-Installazzjoni:

It is recommended to install CO detectors in every room where carbon monoxide leaks may occur, and in all sleeping areas. For optimal detection, consider the following:

  • Near sleeping areas: Install a detector in or near bedrooms to ensure the alarm is heard during sleep.
  • Near fuel-burning appliances: Place a detector in rooms containing furnaces, water heaters, fireplaces, or gas stoves.
  • On walls: Install the detector on a wall, at a height above any doors or windows, but below the ceiling.
Diagram showing recommended placement of CO detectors in a bedroom, living room with fireplace, and child's room.

Image 2: Recommended placement examples for the CO detector in various rooms.

Passi ta' Installazzjoni:

  1. Choose a suitable location on a wall, away from obstructions and restricted areas mentioned in Section 2.
  2. Using the provided mounting accessories (screws and wall plugs), mark the positions for drilling two holes.
  3. Drill it-toqob u daħħal il-plaggs tal-ħajt.
  4. Secure the mounting bracket (if separate) or the detector directly to the wall using the screws.
  5. Ensure the detector is firmly attached to the wall.
Close-up of the CO detector being mounted on a wall with screws.

Image 3: Illustration of the detector being mounted on a wall using screws.

4. Istruzzjonijiet Operattivi

The LIORQUE CO Detector operates continuously once installed. It features LED indicators and an LCD display for status updates.

Indikaturi LED:

The detector uses a 4-color LED indicator system to communicate its status:

  • Green LED (Power): Flashes every 50 seconds, indicating normal operation.
  • Yellow LED (Fault): Indicates a fault or malfunction with the device.
  • Red LED (Alarm): Flashes rapidly and an audible alarm sounds when CO is detected at dangerous levels.
  • White Indicator (Low Battery): Indicates a low battery condition.
Close-up of the CO detector's LED indicators: Green for Power, Yellow for Fault, Red for Alarm.

Image 4: Visual representation of the LED indicators and their meanings.

Display LCD:

The integrated LCD display shows the current CO concentration in parts per million (ppm) and battery status.

LCD display showing a CO concentration of 300 ppm and battery level.

Image 5: The LCD display showing a detected CO level.

Kundizzjonijiet ta' Allarm:

The detector is calibrated to trigger an alarm based on specific CO concentration levels and exposure times, in compliance with EN50291:

  • 50 ppm: Alarm sounds within 60-90 minutes.
  • 100 ppm: Alarm sounds within 10-40 minutes.
  • 300 ppm: Alarm sounds within 3 minutes.

When an alarm is triggered, the red LED will flash rapidly, and an audible alarm of 85 dB will sound. The alarm will continue until the CO concentration drops to a safe level.

Diagram illustrating different CO concentration levels (50 ppm, 100 ppm, 300 ppm) and their corresponding alarm response times.

Image 6: Visual guide to CO alarm response levels and times.

Buttuna tat-Test/Silenzju:

The large central button labeled "TEST/HUSH" allows you to test the detector's functionality and silence an alarm temporarily.

  • Biex Ittestja: Press and hold the button briefly. The detector will emit a series of beeps and flash its LEDs, indicating it is working correctly.
  • To Hush (Silence): In case of a non-emergency alarm (e.g., brief exposure to low CO levels), pressing the button can temporarily silence the alarm for a short period. The detector will continue to monitor CO levels. If CO levels remain high, the alarm will reactivate.
A hand pressing the 'TEST/HUSH' button on the CO detector.

Image 7: Demonstrating the use of the Test/Hush button.

5. Manutenzjoni

Regular maintenance ensures the long-term reliability of your CO detector.

Ħajja tal-batterija:

The LIORQUE CO Detector features an integrated 10-year battery. This means you do not need to replace batteries frequently. The detector is designed to operate for its entire 10-year lifespan without battery replacement.

Sploda view of the CO detector showing internal components, highlighting the 10-year battery and sensor.

Immaġni 8: Interna view highlighting the 10-year battery and sensor life.

Ittestjar regolari:

It is crucial to test your CO detector weekly or monthly to ensure it is functioning correctly. Press the "TEST/HUSH" button as described in Section 4. If the alarm does not sound during the test, refer to the Troubleshooting section.

Tindif:

Dust and debris can accumulate on the detector and affect its performance. Clean the detector regularly (e.g., monthly) by gently wiping the exterior with a soft, damp cloth. Do not use cleaning agents or solvents. Do not spray air fresheners or other aerosols near the detector.

6 Issolvi l-problemi

This section addresses common issues you might encounter with your CO detector.

Ħsejjes ta' Allarm:

  • Jekk l-allarm jinstema ': Immediately move to fresh air outdoors or open all doors and windows to ventilate the area. Do a head count to check that all persons are accounted for. Do not re-enter the premises until the alarm has stopped and the area has been thoroughly ventilated. Contact emergency services or a qualified technician to investigate the source of CO.
  • Allarmi Foloz: Ensure the detector is not installed in restricted areas (e.g., near cooking fumes, in garages). If false alarms persist, contact customer support.

Fault Indicator (Yellow LED) On:

If the yellow LED is continuously lit or flashing, it indicates a fault with the detector. This could mean the sensor is malfunctioning or there is an internal error. In this case, the detector may not be able to detect CO effectively. It is recommended to replace the unit immediately.

Low Battery Indicator (White Indicator) On:

Although the detector has a 10-year battery, if a low battery indicator appears prematurely, it may indicate a defect. Contact customer support for assistance.

Ebda Rispons Matul it-Test:

If the detector does not respond when the "TEST/HUSH" button is pressed, ensure the device is properly powered on. If the issue persists, the unit may be faulty and should be replaced.

7. Speċifikazzjonijiet

BrandLIORQUE
Numru tal-MudellTCS0202A
Dimensjonijiet tal-Prodott11 x 5 x 11 ċm
Piż tal-oġġett150 gramma
Sors tal-EnerġijaBattery Powered (Integrated 10-year Lithium-ion battery)
Tip ta 'allarmJinstema' (85 dB)
Tip tas-SensorElettrokimiku
KonformitàEN50291
Diagram showing the dimensions of the LIORQUE CO detector: 9cm width, 9cm height, 2.5cm depth.

Image 9: Product dimensions of the LIORQUE Carbon Monoxide Detector.

8. Garanzija u Appoġġ

For warranty information or technical support, please refer to the product packaging or contact LIORQUE customer service directly. Contact details are typically provided on the manufacturer's website or within the product documentation included in the box.

Dokumenti Relatati - TCS0202A

Preview Allarm tal-Monossidu tal-Karbonju LIORQUE KD-216LE: Istruzzjonijiet għall-Operazzjoni u Gwida għas-Sigurtà
Istruzzjonijiet komprensivi dwar l-operat u gwida dwar is-sigurtà għall-Allarm tal-Monossidu tal-Karbonju LIORQUE KD-216LE, li jkopru l-installazzjoni, l-użu, il-manutenzjoni, informazzjoni dwar l-avvelenament bis-CO, u s-soluzzjoni tal-problemi.
Preview LIORQUE SM-01 Sound Machine Alarm Clock User Manual
Explore the features and functionalities of the LIORQUE SM-01 Sound Machine Alarm Clock with this comprehensive user manual. Learn how to set time, alarms, use natural sounds, and manage the sleep timer.
Preview LIORQUE Sunrise Alarm Clock Model K2 User Manual
User manual for the LIORQUE Sunrise Alarm Clock, Model K2. Learn how to set up, use features like simulated sunrise, alarms, FM radio, mood lighting, Bluetooth, and more.
Preview LIORQUE Radiowa Stacja Pogodowa z Czujnikiem Zewnętrznym: Termometr, Higrometr, Prognoza Pogody, Zasilana Bateriami
Wielofunkcyjna radiowa stacja pogodowa LIORQUE z czujnikiem zewnętrznym do monitorowania temperatura, wilgotności i prognozy pogody wewnątrz i na zewnątrz. Wyposa distanza w 4,3-calowy ekran LCD, funkcje alarmu, drzemki i kalendarza. Łatwa w konfiguracji, zasilana bateriami.
Preview User Manual: Transcutaneous Electrical Nerve Stimulator KTR-2610
This user manual provides comprehensive instructions for the KTR-2610 Transcutaneous Electrical Nerve Stimulator, covering TENS, EMS, and Fitness modes, operation, maintenance, and safety guidelines.
Preview Manwal tal-Utent ta' Liorque KTR-2610 TENS/EMS/FITNESS
Gwida komprensiva għal-Liorque KTR-2610, elettrostimulatur portabbli tat-TENS, EMS, u FITNESS. Tgħallem dwar il-karatteristiċi, l-użu, il-manutenzjoni, u l-prekawzjonijiet ta' sigurtà tiegħu għal serħan effettiv mill-uġigħ u kondizzjonament tal-muskoli.