1. Introduzzjoni
This manual provides essential information for the safe and efficient operation, installation, and maintenance of your VEVOR Above Ground Pool Pump, Model HAP750. Please read this manual thoroughly before installation and use, and retain it for future reference.
2. Informazzjoni dwar is-Sigurtà
Dejjem segwi l-prekawzjonijiet bażiċi ta’ sigurtà biex tnaqqas ir-riskju ta’ nar, xokk elettriku, u korriment lil persuni.
- Ensure the pump is installed by a qualified professional in accordance with all local and national electrical codes.
- Dejjem skonnettja l-enerġija mill-pompa qabel ma twettaq kwalunkwe manutenzjoni jew servizz.
- Do not run the pump dry. Ensure the pump is filled with water before starting.
- Install the pump at least 10 feet (3 meters) from the inside walls of the pool.
- Use an extension cord only if absolutely necessary and ensure it is rated for outdoor use and the pump's power requirements.
- The pump is designed for use with permanently installed pools and spas. It should not be used with storage tanks.
- Ensure proper grounding. The pump incorporates grounding terminals to connect to ground lines for added security.
3. Prodott Aktarview
The VEVOR Above Ground Pool Pump, Model HAP750, is a single-speed, 1HP pump designed for efficient water circulation and filtration in above-ground pools, hot tubs, and spas.
3.1 Karatteristiċi ewlenin
- 1 HP Premium Copper Motor: Operates at 120V / 60Hz with 3450 RPM, featuring an aluminum motor casing and built-in thermal protection for stable and efficient performance.
- Corrosion-Resistant Thickened Shell: Constructed with a durable PP shell and integrated structure, ensuring leak-free and wear-resistant properties, even with disinfectant-treated water.
- Efficient Water Circulation System: Delivers a maximum water flow of 80 GPM and a maximum head lift of 36 ft (11 m) for rapid water circulation.
- Detachable Filter Basket: Facilitates physical purification, compatible with a sand filter (not included). A transparent PVC cover allows easy monitoring for cleaning.
- Sigurtà Mtejba: Includes grounding terminals for connecting to ground lines.
- Applikazzjoni versatili: Suitable for above-ground pools, hot tubs, spas, and irrigation systems. Not recommended for storage tanks.
3.2 Komponenti
The pump unit typically includes the motor, pump housing with a filter basket, and connection adapters.

This image displays the main pump unit, featuring the motor, pump housing with a clear lid for the filter basket, and several connection adapters for different hose sizes. The pump is black with a metallic motor housing.

This diagram highlights key components of the pump, including the water inlet, water outlet, pump body, detachable transparent lid, grounding terminal, strainer basket, ventilation fan, stable base, and drain plug. It illustrates the integrated corrosion-resistant casing.
4. Konfigurazzjoni u Installazzjoni
Installazzjoni xierqa hija kruċjali għall-prestazzjoni u l-lonġevità tal-pompa. Segwi dawn il-passi bir-reqqa.
4.1 Għażla tas-Sit
- Place the pump on a firm, level surface, ensuring it is at least 10 feet (3 meters) from the pool's edge.
- Ensure the location is well-ventilated and protected from direct sunlight and harsh weather conditions.
- The pump should be positioned below the water level of the pool to facilitate priming.
4.2 Konnessjoni Elettrika
The VEVOR HAP750 pump operates on 120V / 60Hz. All electrical wiring must be performed by a licensed electrician and comply with local and national electrical codes.
- Kun żgur li l-provvista tal-enerġija taqbel mal-volum tal-pompatage rekwiżiti (120V).
- Connect the pump to a dedicated, grounded circuit protected by a Ground Fault Circuit Interrupter (GFCI).
- Utilize the provided grounding terminals to ensure the pump is properly grounded.
This video demonstrates the process of connecting the power cord to a pool pump. It shows opening the junction box, connecting the live, neutral, and ground wires to their respective terminals, and then securing the junction box cover. While the video features a dual-speed pump, the wiring principles for a single-speed pump are similar for the power connection.
4.3 Konnessjoni tal-plaming
- Connect the pool's skimmer line (suction) to the pump's inlet.
- Connect the pump's outlet to the pool's return line (to the filter, then back to the pool).
- Use appropriate hose adapters (1-1/2" and 2" connection adapters are typically included) and hose clamps biex jiġi żgurat siġill li ma jgħaddix ilma minnu.
- Kun żgur li l-konnessjonijiet kollha huma ssikkati biex tevita tnixxijiet ta' arja, li jistgħu jaffettwaw il-prestazzjoni tal-pompa.

This image illustrates the pump with different hose adapters, emphasizing the flexibility in connecting to various plumbing setups. The adapters are crucial for ensuring a secure and leak-free connection between the pump and the pool's filtration system.
5. Istruzzjonijiet Operattivi
5.1 Priming tal-Pompa
Before starting the pump for the first time or after draining, it must be primed to ensure it is filled with water and free of air.
- Ensure all valves are open, allowing water to flow from the pool to the pump.
- Remove the transparent lid from the strainer basket.
- Fill the strainer basket housing completely with water.
- Replace the lid, ensuring it is securely tightened to create an airtight seal.
- Turn on the pump. It should begin to draw water from the pool.
- If the pump does not prime within a few minutes, turn it off, re-fill the strainer housing, and repeat the process.
5.2 Tibda tal-Pompa
Once primed, the pump is ready for operation.
- Kun żgur li l-konnessjonijiet kollha tal-plumbing huma sikuri u mingħajr tnixxija.
- Verify that the filter system (if applicable) is correctly set for filtration.
- Turn on the power to the pump. The pump will begin circulating water.
This video showcases a single-speed pool pump in operation, demonstrating the water circulation and the ease of installation of connection adapters. It highlights the pump's powerful performance and easy maintenance features, including the filter basket.
6. Manutenzjoni
Manutenzjoni regolari tiżgura prestazzjoni ottimali u testendi l-ħajja tal-pompa tiegħek.
6.1 Tindif tal-Basket tal-Għali
The detachable filter basket should be checked and cleaned regularly, especially if water flow decreases or the transparent lid shows accumulated debris.
- Itfi l-pompa u skonnettja l-enerġija.
- Unscrew and remove the transparent lid.
- Neħħi l-qoffa tal-passatur.
- Empty any debris and rinse the basket thoroughly with water.
- Spezzjona l-O-ring fuq l-għatu għal xquq jew xedd; ibdel jekk meħtieġ.
- Place the clean basket back into the housing, ensuring it seats properly.
- Replace the lid and tighten securely.
- Erġa' ħejji l-pompa jekk meħtieġ qabel ma terġa' tibdaha.

Din l-immaġni tipprovdi ċara view of the detachable strainer basket inside the pump housing, illustrating its function in capturing debris like leaves and small stones to prevent them from entering the pump or filter system.
6.2 Winterization
In colder climates, proper winterization is essential to prevent damage from freezing.
- Ixxotta l-ilma kollu mill-pompa u l-pajpijiet tal-plumbing.
- Remove the drain plug from the pump housing.
- Aħżen il-pompa f'post niexef u protett matul l-istaġun barra.
7 Issolvi l-problemi
Jekk tiltaqa' ma' problemi bil-pompa tiegħek, irreferi għall-problemi u s-soluzzjonijiet komuni li ġejjin:
| Problema | Kawża Possibbli | Soluzzjoni |
|---|---|---|
| Il-pompa ma tibdax | Ebda enerġija; GFCI li qabad; tagħbija żejda bil-mutur. | Check power supply; reset GFCI; allow motor to cool and reset thermal protection. |
| Il-pompa taħdem imma l-ilma ma joħroġx | Pump not primed; air leak in suction line; clogged strainer basket. | Prime the pump; check all suction line connections for leaks; clean strainer basket. |
| Fluss ta 'ilma baxx | Clogged strainer basket; dirty filter; air leak. | Clean strainer basket; backwash/clean filter; check for air leaks. |
| Ħsejjes/vibrazzjonijiet eċċessivi | Air leak; cavitation; loose mounting. | Check for air leaks; ensure adequate water supply to pump; tighten mounting bolts. |
8. Speċifikazzjonijiet
| Karatteristika | Speċifikazzjoni |
|---|---|
| Brand | VEVOR |
| Numru tal-Mudell | HAP750 |
| Qawwa | 1 HP |
| Voltage | 120V / 60Hz |
| Veloċità li ddur | 3450 RPM |
| Rata massima tal-fluss | 80 GPM |
| Irfigħ Massimu tar-Ras | 36 pied / 11 m |
| Materjal | Aluminum, Polypropylene (PP) |
| Kulur | Iswed |
| Piż tal-oġġett | 22.93 Liri |
| Dimensjonijiet tal-Prodott | 24.4 x 10 x 11.4 pulzieri |
| Tul tal-kurdun | 35.4 pulzieri / 0.9 m |
| Compatible Sand Filter Size | 16-19 inches (not included) |
| Maximum Pool Capacity | 27,000 Galun |

This graphic provides a visual overview of the pump's physical dimensions and a table summarizing its key technical specifications, including model number, voltage, power, rotating speed, max head lift, max water flow, cord length, compatible sand filter size, and maximum pool gallons.
9. Garanzija u Appoġġ
For warranty information or technical support, please refer to the product packaging or contact VEVOR customer service directly. Keep your purchase receipt for warranty claims.