McKesson MCK8100MATB

McKesson Refrigerator and Freezer Thermometer with Alarm, Dual-Probe

Model: MCK8100MATB

1. Introduzzjoni

This manual provides detailed instructions for the proper setup, operation, and maintenance of your McKesson Refrigerator and Freezer Thermometer with Alarm, Dual-Probe. This device is designed for accurate temperature monitoring in cold storage environments, featuring dual probes, a digital display, and customizable high/low temperature alarms. Please read this manual thoroughly before use to ensure optimal performance and longevity of the product.

2. Prodott Aktarview

The McKesson Dual-Probe Thermometer is a reliable instrument for monitoring temperatures in refrigerators and freezers. It offers precise readings and alerts to help maintain optimal conditions for stored items.

Karatteristiċi ewlenin:

  • Dual-Probe Measurement: Allows simultaneous monitoring of two distinct locations.
  • Waterproof Digital Display: Clear and easy-to-read display with a 10-second refresh rate.
  • Preċiżjoni Għolja: Provides readings with an accuracy of ±0.5°C and a 0.1° display resolution.
  • Max/Min Temperature Alarm: Audible and visual alarms activate when temperatures exceed or fall below user-defined thresholds.
  • NIST Traceable: Each thermometer is certified, sterilized, traceable, and tested against standards calibrated at the National Institute of Standards and Technology.
  • Firxa Wiesgħa ta' Temperatura: Measures temperatures from -58°F to +158°F (-50°C to +70°C).

X'hemm fil-Kaxxa:

  • McKesson Refrigerator/Freezer Thermometer Unit
  • Two Temperature Probes (S1 and S2)
  • Batteries (typically AAA, included)
McKesson Dual-Probe Refrigerator/Freezer Thermometer with packaging box.

This image displays the McKesson Dual-Probe Refrigerator and Freezer Thermometer alongside its retail packaging. The thermometer features a digital display and two external probes.

Components of the McKesson Dual-Probe Thermometer, including the main unit, two probes, and batteries.

An overhead view showing the main thermometer unit, two wired temperature probes (S1 and S2), and two AAA batteries, illustrating all included components.

3. Setup

3.1 Installazzjoni tal-batterija

  1. Sib il-kompartiment tal-batterija fuq wara tal-unità tat-termometru.
  2. Iftaħ l-għatu tal-kompartiment.
  3. Daħħal il-batteriji AAA inklużi, waqt li tiżgura l-polarità korretta (+/-).
  4. Agħlaq l-għatu tal-kompartiment tal-batterija sew.

3.2 Probe Connection and Placement

  1. Connect the two temperature probes (S1 and S2) into their respective ports on the thermometer unit.
  2. Place Probe S1 in the desired location for monitoring (e.g., refrigerator compartment).
  3. Place Probe S2 in the second desired location (e.g., freezer compartment). Ensure probes are not submerged in liquid unless specifically designed for it and are positioned to accurately reflect the ambient temperature of the monitored area.
  4. The main unit can be placed outside the refrigerator/freezer for easy viewing, using its built-in stand or magnetic back (if applicable).
Close-up of the two waterproof temperature probes (S1 and S2) for the McKesson thermometer.

A close-up shot of the two distinct temperature probes, labeled S1 and S2, designed for monitoring temperatures in different environments.

4. Istruzzjonijiet Operattivi

4.1 Power On/Off

The thermometer typically powers on automatically once batteries are installed. There may be a dedicated power button or it may remain on continuously.

4.2 Qari tad-Displej

The digital display shows the current temperature readings for both probes (S1 and S2). It may also show the time and date, and indicators for Max/Min temperatures or alarm status.

Close-up of the McKesson thermometer's digital display showing 21.3°C, 15 minutes, and 36 seconds.

A dettaljata view of the thermometer's digital screen, indicating a current temperature reading of 21.3°C and a time display of 15:36. The S1/S2 indicators and control buttons are also visible.

4.3 Unitajiet tat-Temperatura li Jibdlu (°C/°F)

Press the 'Mode' button (or a dedicated °C/°F button if present) to toggle between Celsius and Fahrenheit temperature units.

4.4 Setting Max/Min Alarms

  1. Press the 'Set' button to enter alarm setting mode.
  2. Use the 'Up' or 'Down' arrow buttons (or 'Mode' button to cycle) to adjust the desired high temperature limit for Probe S1.
  3. Press 'Set' again to confirm and move to the low temperature limit for Probe S1. Adjust as needed.
  4. Repeat the process for Probe S2's high and low temperature limits.
  5. Press 'Set' one last time to exit alarm setting mode.
  6. When the temperature goes above or below these set limits, an audible and visual alarm will trigger.

4.5 Viewing and Clearing Max/Min Recorded Temperatures

  1. Press the 'Mode' button repeatedly to cycle through current temperature, maximum recorded temperature, and minimum recorded temperature for each probe.
  2. To clear the recorded Max/Min temperatures, press and hold the 'Clear' button while viewing the Max or Min readings. This will reset them to the current temperature.

4.6 L-issettjar tal-Ħin u d-Data

Press and hold the 'Time/Date Set' button to enter time and date setting mode. Use the 'Up' or 'Down' arrow buttons to adjust values and 'Set' to confirm and move to the next setting (e.g., hour, minute, day, month, year).

McKesson Dual-Probe Thermometer in use on a wooden surface, with probes placed nearby.

The thermometer unit is shown on a wooden countertop, displaying a temperature of 24.0°C and a time of 12:10:05. Its two probes are positioned next to it, ready for temperature monitoring.

5. Manutenzjoni

5.1 Tindif

Wipe the thermometer unit and probes with a soft, damp cloth. Do not use abrasive cleaners or immerse the main unit in water. The probes are waterproof and can be cleaned with mild soap and water if necessary, then rinsed thoroughly.

5.2 Sostituzzjoni tal-batterija

When the display becomes dim or the unit stops functioning, replace the batteries. Follow the battery installation steps in Section 3.1. Dispose of old batteries according to local regulations.

5.3 Ħażna

If storing the thermometer for an extended period, remove the batteries to prevent leakage. Store the unit and probes in a cool, dry place away from direct sunlight and extreme temperatures.

6 Issolvi l-problemi

ProblemaKawża PossibbliSoluzzjoni
L-ebda wiri jew wiri mudlamBatteriji mejta jew installati ħażinIbdel il-batteriji, waqt li tiżgura l-polarità korretta.
Qari mhux korrett tat-temperaturaProbe not properly connected or damaged; probe placed incorrectlyEnsure probes are securely plugged in. Reposition probes to accurately measure ambient air. If problem persists, probe may be faulty.
Alarm not sounding/visualizingAlarm limits not set correctly; alarm function disabledVerify alarm settings (Section 4.4). Ensure alarm is enabled (if applicable).
Display shows 'LLL' or 'HHH'Temperature is outside the measurable rangeMove the probe to an environment within the specified temperature range (-58°F to +158°F).

7. Speċifikazzjonijiet

KaratteristikaSpeċifikazzjoni
Numru tal-MudellMCK8100MATB
Firxa tat-Temperatura-58°F sa +158°F (-50°C sa +70°C)
Eżattezza±0.5°C
Riżoluzzjoni tal-Wiri0.1°
Riffriskar Rata10 sekonda
Tip ta' SondaDual, Waterproof
Dimensjonijiet tal-Prodott8.25 x 5 x 2.5 pulzieri
Piż tal-oġġett7.2 uqija

8. Garanzija u Appoġġ

For general questions or technical support regarding your McKesson Refrigerator and Freezer Thermometer, please refer to the contact information provided on the product packaging or the official McKesson websit.

  • General Questions: Call 1-800-777-4908
  • Technical Support: Call 1-777-300-9100

Please retain your purchase receipt for warranty purposes. Specific warranty details may vary and are typically outlined in the product packaging or on the manufacturer's websit.

Dokumenti Relatati - MCK8100MATB

Preview Manwal tal-Utent tat-Termometru tar-Refriġeratur/Friżer McKesson DUAL PROBE MCK8100MATB
Manwal dettaljat għall-utent għat-Termometru tar-Refriġeratur/Friżer McKesson DUAL PROBE (MCK8100MATB). Jinkludi karatteristiċi, speċifikazzjonijiet, struzzjonijiet ta' setup, konfigurazzjoni tas-settings, u noti għas-soluzzjoni tal-problemi.
Preview McKesson Refrigerator/Freezer Thermometer TRIPLE DISPLAY DUAL PROBE MCK821RFV2 User Manual
User manual and specifications for the McKesson Refrigerator/Freezer Thermometer TRIPLE DISPLAY DUAL PROBE (Model MCK821RFV2). Features include high accuracy, min/max memory, low/high alarm settings, and NIST traceability.
Preview McKesson Refrigerator/Freezer Thermometers: Product Overview u Speċifikazzjonijiet
Comprehensive guide to McKesson Refrigerator/Freezer Thermometers, detailing features, benefits, technical specifications, and ordering information for models MCK821RFV, MCK895RFV, MCK8100MATB, MCK80021P, and MCK80022P.
Preview Termometru tar-Refriġeratur/Friżer mingħajr fili McKesson MCK895WRFT - Wiri Tlieta, Sonda Unika
Manwal tal-utent u speċifikazzjonijiet għat-Termometru tar-Refriġeratur/Friżer Wireless McKesson, mudell MCK895WRFT. Dettalji dwar karatteristiċi bħal wiri triplu, sonda waħda, ċifra kbira, konnettività mingħajr fili, settings tal-allarm, u kodiċijiet ta' żball.
Preview McKesson Refrigerator/Freezer Thermometers: Product Catalog and Specifications
Explore the range of McKesson Refrigerator/Freezer Thermometers, featuring digital displays, data logging capabilities, NIST traceability, and alarms for precise temperature monitoring in critical cold storage environments.
Preview McKesson Triple Display Refrigerator/Freezer Thermometer | MCK895RFV
Detailed information on the McKesson Triple Display Single Probe Large Digit Refrigerator/Freezer Thermometer (MCK895RFV), including features, specifications, operation, and alarm settings. NIST traceable.