OONO D-1561T

OONO DIN Rail Mount AC 120V NEMA 5-15R 4 Receptacles Outlet Power Strip Module D-1561T User Manual

Model: D-1561T

Marka: OONO

1. Introduzzjoni

This user manual provides essential information for the safe and efficient operation of your OONO DIN Rail Mount AC 120V NEMA 5-15R 4 Receptacles Outlet Power Strip Module, Model D-1561T. Please read this manual thoroughly before installation and use, and retain it for future reference. This module is designed for integration into electrical systems requiring DIN rail mounting and offers four NEMA 5-15R outlets with an integrated rocker switch and thermal circuit breaker for overload protection.

2. Informazzjoni dwar is-Sigurtà

Always adhere to local electrical codes and safety regulations during installation and operation. Improper installation or use can result in electric shock, fire, or damage to equipment.

3. Prodott Aktarview

3.1 Karatteristiċi

3.2 Komponenti

The OONO D-1561T module consists of the following key components:

3.3 Stampi tal-Prodott

Quddiem view of the OONO D-1561T power strip module
Quddiem view of the OONO D-1561T power strip module, showing the four NEMA 5-15R receptacles, the rocker switch with reset button, and input terminals.
Angolat view of the OONO D-1561T power strip module
Angolat view of the OONO D-1561T module, highlighting the robust construction and terminal block connections.
Angolat ieħor view of the OONO D-1561T power strip module
A different angled perspective of the power strip module, showing the side profile and receptacle arrangement.
Schematic diagram of the OONO D-1561T power strip module
Electrical schematic diagram illustrating the internal wiring and connections of the NEMA 5-15R outlets, circuit breaker, and input terminals.
Dimensional drawing of the OONO D-1561T power strip module
Detailed dimensional drawing of the OONO D-1561T module, providing measurements for installation planning.
OONO D-1561T power strip module mounted on a DIN rail
The OONO D-1561T power strip module securely mounted on a standard DIN rail, demonstrating its intended installation method.
Qiegħ view of the OONO D-1561T power strip module
Qiegħ view of the OONO D-1561T module, showing the DIN rail mounting clips and overall construction.

4. Setup u Installazzjoni

4.1 Mounting on DIN Rail

The D-1561T module is designed for quick and secure mounting on a standard 35mm DIN rail.

  1. Ensure the DIN rail is properly installed and secured within your electrical enclosure.
  2. Align the module's DIN rail clips with the top edge of the DIN rail.
  3. Press the module firmly downwards until it clicks into place on the rail.
  4. To remove, gently pull the bottom edge of the module away from the rail while lifting upwards.

Video demonstrating the installation of a similar OONO DIN rail mount power strip module onto a DIN rail. This video illustrates the secure mounting process.

4.2 Istruzzjonijiet tal-Wiring

Before wiring, ensure all power is OFF at the source. Connect the incoming AC 120V power to the input terminal blocks as follows:

The input terminals accommodate 26~10 AWG wire. For optimal and secure connections, it is highly recommended to use wire ferrules on the stripped ends of your wires before inserting them into the terminal blocks. Strip approximately 8mm of insulation from the wire ends. Tighten the Metric M3 slotted screws firmly to ensure a reliable connection.

Wirja tal-vidjoasing the wiring and functionality of an OONO DIN rail mount power module with a rocker switch and overload protector. This video provides a visual guide to connecting the power input and operating the switch.

5. Istruzzjonijiet Operattivi

5.1 Tixgħel/Jitfi

The module features a rocker switch with an integrated thermal circuit breaker for controlling power to the four NEMA 5-15R outlets.

5.2 Protezzjoni ta' Tagħbija Eċċessiva

The integrated 15 Amp thermal circuit breaker protects connected devices from overcurrent conditions. If the total current draw from the outlets exceeds 15 Amps, the circuit breaker will trip, automatically cutting power to the outlets. The rocker switch will move to a central or 'TRIPPED' position.

6. Manutenzjoni

Regular maintenance ensures the longevity and safe operation of your power strip module.

7 Issolvi l-problemi

ProblemaKawża PossibbliSoluzzjoni
No power to outlets.Rocker switch is OFF or tripped.Press the rocker switch to the 'ON' position. If tripped, reduce load and reset.
No power to outlets.No incoming power to the module.Check the main circuit breaker and power source supplying the module. Verify input wiring.
Is-circuit breaker jitlaq ripetutament.Overload condition (total current exceeds 15 Amps).Reduce the number of devices connected or replace high-power devices with lower-power alternatives. Ensure total load is below 15 Amps.
Loose connections or arcing at terminals.Improperly tightened terminal screws or inadequate wire preparation.Disconnect power, re-strip wires, use ferrules, and securely tighten terminal screws. Consult a qualified electrician if unsure.

8. Speċifikazzjonijiet

SpeċifikazzjoniValur
Numru tal-MudellD-1561T
BrandOONO
Ħidma VoltageAC 120V
Ħwienet tal-Enerġija Totali4 (NEMA 5-15R)
Single Receptacle Rated Current15 Amps
Total Output Rated Current15 Amps (limited by overload protector)
Overload Protector Current15 Amps
Input Terminals Pitch7.62mm / 0.3"
Max Input Current per Position30 Amps
Daqs tal-Wajer Kompatibbli26 ~ 10 AWG
It-tul tat-tqaxxir8mm
Tip ta' kaminMetric M3 slotted screw
DIN Rail Compatibilityferrovija 35mm
MaterjalHigh quality fireproof nylon
ĊertifikazzjonijietUL, CE, CQC (for specific components)
Dimensjonijiet tal-Pakkett8.5 x 2.6 x 2.09 pulzieri
Piż tal-oġġett8.47 uqija

9. Garanzija u Appoġġ

For warranty information and technical support, please refer to the product packaging or contact OONO customer service directly. Keep your purchase receipt as proof of purchase.

You can visit the OONO Store for more information: OONO Store on Amazon

Dokumenti Relatati - D-1561T

Preview OONO F-1063B Manual and Automatic Transfer Switch - 120V 15A ATS
Detailed guide for the OONO F-1063B Manual and Automatic Transfer Switch. Learn about its features, specifications, installation, and safety for switching between inverter/generator and utility power sources.
Preview OONO F-1030 Serje DPST 1NO 1NC 8Amp Latching Relay Module | Technical Specifications
Detailed technical specifications, features, and wiring diagrams for the OONO F-1030 series DPST 1NO 1NC 8Amp Latching Relay Module. Covers input control modes, output switch capabilities, voltage versions, and dimensions.
Preview Manwal tal-Utent tar-Relay tat-Tisħin Elettriku OONO F-1057
Istruzzjonijiet u speċifikazzjonijiet għar-Relay tat-Tisħin Elettriku li Jixgħel/Jitfi OONO F-1057 b'Transformer ta' 24V Inkorporat, iddisinjat għal tagħbijiet reżistivi AC 120V ikkontrollati minn vultaġġ baxxtagTermostati.
Preview OONO F-1040 Awtomatika Volum BaxxtagModulu ta' Diskonnessjoni e: Karatteristiċi, Speċifikazzjonijiet, u Installazzjoni
Informazzjoni dettaljata dwar l-OONO F-1040 Automatic Low VoltagModulu ta' Skonnettjar e, inklużi l-karatteristiċi tiegħu, il-volum operattivtage, klassifikazzjoni tal-kurrent, gwida għall-installazzjoni, u speċifikazzjonijiet għall-protezzjoni tal-batteriji minn skariku profond.
Preview OONO F-1021 Serje 50 Amp Modulu tar-Relay 'il Quddiem u lura - Speċifikazzjonijiet Tekniċi
Speċifikazzjonijiet tekniċi komprensivi, karatteristiċi, dijagrammi tal-wajers, u dimensjonijiet għas-serje OONO F-1021 50 Amp Modulu ta' Relay 'il Quddiem u Reverse, iddisinjat għal applikazzjonijiet ta' kontroll tal-mutur li jeħtieġu treġġigħ lura tal-moviment.
Preview OONO 10 Amp Modulu tar-Relay 'il Quddiem u lura Serje F-1020: Gwida għall-Utent
Gwida dettaljata għas-serje OONO F-1020 10 Amp Modulu tar-Relay 'il Quddiem u lura, li jkopri l-karatteristiċi, l-ispeċifikazzjonijiet, id-dijagrammi tal-wajers, u d-dimensjonijiet għall-verżjonijiet ta' 5V, 12V, u 24V.