Aquatec 5851-7E12-J574

Manwal tal-Utent tal-Pompa tad-Domanda tal-Kunsinna Aquatec DDP 5800 RO

Introduzzjoni

This manual provides essential information for the safe and efficient installation, operation, and maintenance of your Aquatec DDP 5800 RO Delivery Demand Pump. Please read these instructions thoroughly before beginning installation or operation to ensure proper function and longevity of the product. The Aquatec DDP 5800 is designed to enhance the performance of tank-based reverse osmosis (RO) systems by increasing water pressure and ensuring consistent flow.

Informazzjoni Importanti dwar is-Sigurtà

TWISSIJA: Nuqqas li ssegwi dawn l-istruzzjonijiet ta’ sigurtà jista’ jirriżulta f’xokk elettriku, nar, korriment serju, jew ħsara lill-proprjetà.

Prodott Overview u Karatteristiċi Ewlenin

The Aquatec DDP 5800 is a high-performance demand pump designed to optimize your reverse osmosis system. It ensures consistent water pressure and flow, even when the incoming city water pressure is low.

Aquatec DDP 5800 RO Delivery Demand Pump and packaging

Image: The Aquatec DDP 5800 pump shown alongside its product packaging, highlighting its compact design and included power cord.

Aquatec DDP 5800 pump with key specifications

Image: A close-up of the Aquatec DDP 5800 pump, detailing its specifications such as 0.7 GPM flow, 60 PSI pressure, and 115 VAC operation, along with push-to-connect ports for 3/8-inch tubing.

Karatteristiċi ewlenin:

No sound icon over Aquatec pump

Image: An icon indicating quiet operation, superimposed over a portion of the Aquatec DDP 5800 pump, emphasizing its low noise output.

Diagram showing water flow, pressure detection, and pump activation

Image: A diagram illustrating the pump's on-demand functionality: water flow leads to pressure detection, which then triggers pump activation.

Speċifikazzjonijiet Tekniċi

SpeċifikazzjoniDettall
Numru tal-Mudell5851-7E12-J574
ManifatturAquatec
DistributurESP Water Products
Rata massima tal-fluss0.7 Galluni Kull Minuta (GPM)
Pressjoni Operattiva70 PSI (Pump Output), 60 PSI (Pressure Switch)
Voltage120 Volts AC
Kurrenti0.3 Amps @ 60 PSI
Sors tal-EnerġijaCorded Elettriku
Konnessjonijiet3/8-inch Quick Connect Ports
MaterjalPolypropylene (PP), Stainless Steel
Dimensjonijiet tal-Prodott (L x W x H)7.51" x 3.6" x 3.38"
Piż tal-oġġett6.25 liri
Komponenti InklużiPower Cord (6-foot, 3-prong plug)

Setup u Installazzjoni

The Aquatec DDP 5800 is designed for straightforward installation. Most users can mount the pump and connect tubing themselves. However, for any hard wiring or code-related electrical work, it is recommended to consult a qualified electrician.

Passi ta' Installazzjoni:

  1. Agħżel Post: Select a dry, stable location near your RO system and a 115 VAC power outlet. Ensure adequate ventilation.
  2. Immuntar il-Pompa: Securely mount the pump using appropriate hardware (not included) to prevent vibration and movement.
  3. Qabbad it-tubi: The pump features 3/8-inch push-to-connect ports. Ensure your RO system uses 3/8" OD tubing. If 1/4" tubing is used, a reducing fitting (sold separately) will be required.
    • Connect the outlet of your RO storage tank (or post-filter) to the pump's inlet port.
    • Connect the pump's outlet port to your RO faucet or other dispensing point.
    • Ensure all connections are firm and leak-free.
  4. Konnessjoni Elettrika: Plug the 6-foot power cord into a grounded 115 VAC outlet. The pump includes a 60 PSI pressure switch for automatic operation.
  5. Kontroll tas-Sistema: After installation, slowly turn on the water supply to the RO system and check for any leaks. Allow the RO tank to fill completely before operating the pump.
Aquatec 5800 Pump Installation Diagram

Image: A diagram illustrating the typical installation of the Aquatec DDP 5800 pump within an under-sink reverse osmosis system, showing connections to the RO filters, storage tank, and faucet.

Hand connecting tubing to a quick-connect port on the pump

Image: A hand demonstrating the simple push-to-connect method for attaching tubing to the pump, highlighting the ease of installation.

Istruzzjonijiet Operattivi

The Aquatec DDP 5800 pump operates automatically based on demand from your RO system. Once properly installed and connected to power, it will activate when water is drawn from the RO faucet and the pressure drops below the set point of the internal pressure switch (approximately 60 PSI).

Manutenzjoni

The Aquatec DDP 5800 pump is designed for reliable, low-maintenance operation. Regular checks can help ensure its continued performance.

For any internal maintenance or repairs, it is recommended to contact qualified service personnel or the manufacturer.

Gwida dwar is-sejbien ta 'problemi

This section provides solutions to common issues you might encounter with your Aquatec DDP 5800 pump. Always disconnect power before inspecting the pump.

ProblemaKawża PossibbliSoluzzjoni
Il-pompa ma tixgħelx.No power; faulty power cord/outlet; pressure switch not activating.Check power connection and outlet. Ensure RO faucet is open and water is being drawn. Verify pressure switch functionality.
Fluss jew pressjoni baxxa tal-ilma.Clogged RO filters; kinked/blocked tubing; insufficient inlet pressure; pump malfunction.Replace RO filters if due. Inspect tubing for obstructions. Ensure adequate water supply to the RO system. Contact support if pump is suspected faulty.
Il-pompa taħdem kontinwament.Leak in the system; faulty pressure switch; RO tank not fully pressurized.Check all connections for leaks. Ensure RO tank is fully charged. If problem persists, pressure switch may need replacement or adjustment (contact support).
Ħoss jew vibrazzjoni mhux tas-soltu.Loose mounting; air in the lines; internal component issue.Ensure pump is securely mounted. Bleed air from the system by running water for a few minutes. If noise persists, contact support.

Garanzija u Appoġġ għall-Klijent

For warranty information, technical assistance, or to purchase replacement parts, please contact ESP Water Products, the authorized distributor, or Aquatec directly.

Dokumenti Relatati - 5851-7E12-J574

Preview Gwida għall-Installazzjoni u t-Tħaddim tal-Pompa tal-Kunsinna/Domanda tas-Serje Aquatec DDP
Linji gwida operattivi u ta' installazzjoni għall-Pompi tal-Kunsinna/Domanda tas-Serje Aquatec DDP (Mudelli 550, 5800, 7800). Ikopru prekawzjonijiet ta' sigurtà, immuntar, plumbing, setup elettriku, u rakkomandazzjonijiet ta' manutenzjoni.
Preview Istruzzjonijiet għall-Immuntar tat-Tazza tal-Ġbid tal-Banju Aquatec
Gwida pass pass dwar kif twaħħal it-tazzi tal-ġbid għall-Aquatec Bathlift, inkluża l-installazzjoni tat-tazza tal-ġbid ta' quddiem u ta' wara.
Preview Manwal tal-Utent tal-Aquatec® Beluga Bathlift
Dan il-manwal tal-utent jipprovdi informazzjoni u struzzjonijiet essenzjali għall-użu sikur u xieraq tal-Aquatec® Beluga bathlift, apparat mediku ddisinjat biex jgħin lill-utenti fl-għawm.
Preview Istruzzjonijiet tal-Assemblaġġ taċ-Ċinturin Pelviku/tas-Sider Aquatec ORCA
Istruzzjonijiet għall-assemblaġġ għaċ-Ċinturin Pelviku u ċ-Ċinturin tas-Sider Aquatec ORCA, inkluż l-ambitu tal-kunsinna, il-prekawzjonijiet ta' sigurtà, u gwida għall-installazzjoni pass pass.
Preview Manwal tal-Utent tas-Sedil tat-Tojlit Imqajjem Aquatec Pure Cala
Manwal tal-utent għas-sedil tat-tojlit imqajjem Aquatec Pure Cala minn Invacare. Jipprovdi struzzjonijiet dwar it-twaqqif, il-manutenzjoni, is-sigurtà, u l-użu maħsub għal aċċessibilità u kumdità mtejba.
Preview Gwida għall-Installazzjoni tal-Kuxxin Artab Aquatec Pure Cala
Istruzzjonijiet pass pass għall-installazzjoni tal-Aquatec Pure Cala Soft Cushion. Tgħallem kif twaħħal ir-riser tas-sedil tat-tojlit artab għal kumdità u aċċessibilità mtejba.