1. Introduzzjoni
This manual provides essential information for the safe and efficient operation of your ProCom MN300TBA-B Ventless Natural Gas Blue Flame Space Heater. Please read all instructions carefully before installation and use. Retain this manual for future reference.

Figure 1: ProCom MN300TBA-B Ventless Natural Gas Blue Flame Space Heater.
2. Informazzjoni Importanti dwar is-Sigurtà
TWISSIJA: Installazzjoni, aġġustament, alterazzjoni, servizz jew manutenzjoni mhux xierqa jistgħu jikkawżaw ħsara lill-proprjetà, korriment, jew mewt. Aqra sew l-istruzzjonijiet dwar l-installazzjoni, it-tħaddim u l-manutenzjoni qabel tinstalla jew isservi dan it-tagħmir.
- This heater is hot while in operation. Do not touch the hot surfaces. Keep children, clothing, and furniture away.
- Żomm il-berner u l-kompartiment tal-kontroll nodfa.
- This heater shall not be installed in a bedroom or a bathroom.
- Taħżinx jew tużax gażolina jew fwar u likwidi oħra li jaqbdu fil-viċinanza ta' dan jew kwalunkwe apparat ieħor.
- Ensure adequate ventilation. Ventless gas heaters consume oxygen from the room.
- A built-in Oxygen Depletion Sensor (ODS) system immediately shuts down the heater if carbon monoxide or lack of oxygen is detected.
- For your safety, always install a carbon monoxide detector in your home.
3. Karatteristiċi tal-prodott
The ProCom MN300TBA-B heater offers efficient heating with several key features:
- Teknoloġija: Produces 30,000 Maximum BTU using Natural Gas, heating up to 1400 sq. ft.
- Affidabbli: Features a thermostat control with High/Medium/Low settings for optimal heat flow.
- Eleganti: Slim and modern profile, suitable for wall mounting or floor placement with included base feet.
- Sikur: Equipped with a push-button ignition and a built-in pilot Oxygen Depletion Sensor (ODS) for safety. ANSI Certified.
- Konvenjenti: Operates without electricity, making it suitable for power outages.

Figure 2: Key features of the ProCom Ventless Heater.

Figure 3: Included components and fuel type.
4. Setup u Installazzjoni
This heater can be installed as a wall-mounted unit or placed on the floor using the provided base feet. Professional installation is recommended for gas connections.
4.1 Spakkjar u Spezzjoni
Carefully remove the heater from its packaging. Inspect for any damage. Ensure all components, including base feet and wall mount hardware, are present.
4.2 Konsiderazzjonijiet dwar il-Kollokazzjoni
- Ensure the heater is placed on a level, stable surface if using base feet.
- Maintain proper clearances from combustible materials as specified in the full installation instructions.
- Do not install in a bedroom or bathroom.
- Ensure adequate ventilation in the room where the heater is installed.
4.3 Għażliet ta 'Immuntar
The heater comes with hardware for both wall mounting and floor placement.
- Muntaġġ tal-ħajt: Use the included wall bracket and fasteners to securely attach the heater to a suitable wall surface.
- Saqajn Bażiċi: Attach the provided base feet to the bottom of the heater for freestanding operation.

Figure 4: Heater with base feet, highlighting blue flame technology.

Figura 5: Dimensjonijiet tal-prodott għall-ippjanar tal-installazzjoni.
4.4 Konnessjoni tal-Gass
This heater operates on Natural Gas. Connect the heater to your natural gas supply line according to local codes and manufacturer instructions. It is highly recommended to have a qualified professional perform the gas connection to ensure safety and proper function.
5. Istruzzjonijiet Operattivi
Follow these steps to operate your ProCom Ventless Natural Gas Heater:
5.1 tqabbid
- Kun żgur li l-provvista tal-gass tkun mixgħula.
- Turn the thermostat control knob to the 'PILOT' setting.
- Push and hold the control knob in while simultaneously pressing the ignitor button repeatedly until the pilot flame lights.
- Kompli żomm il-pum tal-kontroll għal madwar 30-60 sekonda wara li tixgħel il-boċċa pilota biex tħalli t-termokoppja tisħon. Itlaq il-pum bil-mod. Jekk il-boċċa pilota tintefa, irrepeti l-proċess.
5.2 Adjusting Heat (Thermostat Control)
Once the pilot is lit, turn the thermostat control knob to your desired heat setting. The heater offers High, Medium, and Low settings to maintain a comfortable room temperature.
5.3 Tfiq
- To turn off the main burner, turn the thermostat control knob to the 'OFF' position. The pilot light will remain lit.
- To completely shut down the heater (including the pilot light), turn the control knob to 'OFF PILOT'.
- For extended periods of non-use, it is recommended to turn off the main gas supply valve to the heater.

Figure 6: Ignitor and Thermostat Controls.
Video 1: Product Summary Video demonstrating general features and operation.
6. Manutenzjoni
Manutenzjoni regolari tiżgura l-lonġevità u t-tħaddim sikur tal-ħiter tiegħek.
- Tindif: Keep the burner and control compartment clean. Use a vacuum cleaner to remove dust and lint from the air intake and outlet grilles.
- Spezzjoni tad-Dawl Pilota u l-Burner: Periodically check the pilot light and main burner flames for proper appearance (blue, steady flame). Refer to the full manual for detailed flame characteristics.
- Konnessjonijiet tal-gass: Annually inspect all gas connections for leaks using a soap solution. Never use an open flame to check for gas leaks.
- Servizz professjonali: Huwa rrakkomandat li l-heater tiegħek jiġi spezzjonat minn tekniku tas-servizz kwalifikat mill-inqas darba fis-sena.
7 Issolvi l-problemi
If you encounter issues with your heater, refer to the following common troubleshooting steps. For persistent problems, contact a qualified service technician.
| Problema | Kawża Possibbli | Soluzzjoni |
|---|---|---|
| Il-pilota mhux se jixgħel | No gas supply; Air in gas line; Pilot orifice clogged | Check gas valve; Purge air from line; Clean pilot orifice |
| Il-pilota mhux se jibqa' mixgħul | Thermocouple faulty; Pilot flame too small | Replace thermocouple; Adjust pilot flame |
| Il-berner prinċipali mhux se jixgħel | Pilot not lit; Thermostat set too low; Main burner orifice clogged | Light pilot; Adjust thermostat; Clean burner orifice |
| Heater produces odor | New unit burn-off; Dust/debris on burner; Inadequate ventilation | Allow initial burn-off; Clean heater; Ensure proper ventilation |
8. Speċifikazzjonijiet
| Attribut | Dettall |
|---|---|
| Brand | ProCom |
| Numru tal-Mudell | MN300TBA-B |
| Tip ta' Fjuwil | Gass Naturali |
| Output BTU | 30,000 BTU |
| Kopertura tat-Tisħin | Sa 1400 pied kwadru. |
| Karatteristika Speċjali | Adjustable Temperature (Thermostat Control) |
| Kulur | Abjad |
| Fattur tal-Formola | Pedestall (Immuntar fuq l-Art) |
| Tip ta 'Immuntar | Floor Mount, Wall Mount |
| Dimensjonijiet tal-Prodott | 8"D x 29"W x 28"H |
| Piż tal-oġġett | 29.7 liri |
| Tip ta' Burner | Fjamma Blu |
| UPC | 848660008383 |
9. Garanzija u Appoġġ
For warranty information and customer support, please refer to the documentation included with your product or visit the official ProCom websit. Żomm l-irċevuta tax-xiri tiegħek għal pretensjonijiet ta' garanzija.