Introduzzjoni
This manual provides detailed instructions for the installation, operation, and maintenance of your OREiN 3-in-1 Bathroom Exhaust Fan. This unit integrates a powerful exhaust fan, an adjustable LED light, and a smart humidity sensor to enhance your bathroom environment. Please read this manual thoroughly before installation and use to ensure proper function and safety.

Image: The OREiN 3-in-1 Bathroom Exhaust Fan, showcasing its integrated LED light and sleek design. Below are three examples of the selectable light color temperatures: warm white (3000K), bright white (4000K), and daylight (5000K).
Informazzjoni dwar is-Sigurtà
- Always disconnect power at the circuit breaker before installing or servicing the fan.
- Installation must comply with all local electrical codes and standards.
- Żgura ertjar xieraq biex tevita xokk elettriku.
- Dan il-fann huwa ddisinjat għall-użu fuq ġewwa biss.
- Do not use this fan with solid-state speed control devices unless specifically approved.
- For optimal safety, it is recommended to wire this unit into a Ground Fault Circuit Interrupter (GFCI) protected circuit.
- The light and fan functions may require separate wiring circuits or a double switch for independent operation. Failure to separate circuits may result in unintended light behavior.
Kontenut tal-Pakkett
Iċċekkja li l-komponenti kollha huma preżenti qabel tibda l-installazzjoni:
- OREiN Bathroom Exhaust Fan with Integrated LED Light
- Fast-install bracket
- Manwal ta' Istruzzjoni
Setup u Installazzjoni
This fan is designed for ceiling installation between joists and requires standard 6-inch ducting. Please ensure your ceiling opening and duct size are compatible before proceeding.
Dimensions and Opening Requirements
- Fan Housing Size: 12.87 pulzier (W) x 10.59 pulzier (F) x 7.91 pulzier (Għ)
- Light Cover Size: 13.1 pulzier x 13.1 pulzier
- Recommended Ceiling Opening Size: 11.81 pulzier x 11.02 pulzier
- Tubi: Standard 6-inch diameter

Image: Diagram illustrating the dimensions of the fan housing (12.87"x10.59"x7.91") and the light cover (13.1"x13.1"), along with the recommended ceiling opening size (11.81"x11.02") and 6-inch duct connection.
Passi ta 'installazzjoni
- Ipprepara l-Ftuħ tas-Saqaf: Cut an opening in the ceiling according to the recommended size (11.81''x11.02''). If replacing an existing fan, ensure the new opening matches or can be adjusted.
- Immonta l-Housing: Secure the fan housing between the ceiling joists using the fast-install bracket.
- Qabbad il-Kanal: Attach the 6-inch ductwork to the fan's exhaust port. Ensure a secure and airtight connection.
- Wiring Elettriku: Connect the electrical wiring according to the provided wiring diagram. It is crucial to ensure the light and fan circuits are wired correctly, potentially requiring separate switches for independent control.
- Installa l-Għatu tad-Dawl: Once wiring is complete and tested, attach the light cover to the fan housing.

Image: A three-step visual guide demonstrating the installation process: Step 1 shows the fan housing in the ceiling, Step 2 shows the mounting bracket, and Step 3 shows the light cover being attached to the installed fan.
Dijagramma tal-Wiring
Refer to the following diagram for electrical connections. A qualified electrician should perform all wiring.

Image: A detailed wiring diagram showing connections for the light, humidity sensor, fan power module, motor, and ground. It indicates black wires to the switch and white wires to neutral, with green to ground. Wire connectors are also shown.
Istruzzjonijiet Operattivi
Operazzjoni tas-Sensor tal-Umdità
- Modalità Awtomatika: The fan will automatically activate when the humidity level in the bathroom reaches 60%. A green LED indicator light will illuminate to confirm humidity mode is active.
- Modalità Manwali: To operate the fan continuously, move the wall switch to the "ON" position. A red LED indicator light will illuminate.
- Modi ta' Qlib: To toggle between Automatic (humidity sensing) and Manual modes, cycle the wall switch of the fan to the "OFF" position and then back to "ON".

Image: Two panels illustrating the humidity sensor modes. The top panel shows Manual Mode with a red LED indicator, indicating continuous fan operation. The bottom panel shows Humidity Sensing Mode with a green LED indicator, signifying automatic activation at 60% humidity. A separate image shows a hand operating a wall switch to cycle modes.
Operazzjoni tad-Dawl LED
- Luminożità: The integrated LED light provides 1500 lumens of illumination.
- Color Temperature Selection (3CCT): Choose between Warm White (3000K), Bright White (4000K), or Daylight (5000K) by sliding the toggle switch located on the back of the light shade during installation or maintenance.
- Modalità Dawl bil-Lejl: To activate the 2200K night light, switch the main light switch OFF and then back ON again within 2 seconds.
- Kompatibilità: This unit is not compatible with dimmer switches or timer switches.

Image: Three distinct bathroom scenes demonstrating the different color temperatures of the LED light: 5000K (Daylight), 4000K (Bright White), and 3000K (Warm White). A small inset image shows the toggle switch for selection.

Image: An illustration highlighting the 3CCT (Color Correlated Temperature) selectable feature and the nightlight function. It shows the fan's light glowing in a warm 2200K hue, indicating nightlight mode, with specifications for 18W power, 3CCT-1500lm, and Nightlight-200lm.
Manutenzjoni
Manutenzjoni regolari tiżgura prestazzjoni ottimali u lonġevità tal-fann tal-egżost tiegħek.
- Tindif tal-Grelja: Periodically remove the light cover and clean it with a soft, damp drapp. Tużax tindif li joborxu.
- Tindif tax-Xfafar tal-Fann: With power disconnected, gently wipe the fan blades and interior of the housing to remove dust and debris.
- Spezzjoni: Annually inspect the ductwork for any blockages or damage.
Issolvi l-problemi
| Problema | Kawża Possibbli | Soluzzjoni |
|---|---|---|
| Il-fann ma jixgħelx. | Bla dawl, wajers maħlula, swiċċ difettuż. | Check circuit breaker. Verify all wiring connections are secure. Test wall switch. |
| Id-dawl ma jixgħelx. | No power, loose wiring, faulty switch, LED module issue. | Check circuit breaker. Verify all wiring connections. Ensure light circuit is separate from fan. |
| Il-fann jagħmel storbju eċċessiv. | Ductwork obstruction, improper duct size, loose mounting, motor issue. | Check ductwork for obstructions. Ensure 6-inch ducting is used without reducers if possible. Verify fan is securely mounted. |
| Humidity sensor not activating. | Fan in manual mode, sensor malfunction. | Cycle wall switch OFF then ON to ensure fan is in humidity sensing mode (green LED). If issue persists, contact customer support. |
| Light settings bypass or change unexpectedly. | Light and fan circuits are not separated. | Ensure the light and fan are wired on separate circuits or controlled by a double switch to prevent interference. |
Speċifikazzjonijiet tal-Prodott
| Karatteristika | Speċifikazzjoni |
|---|---|
| Brand | OREIN |
| Isem tal-Mudell | OL17003 |
| Numru tal-Parti | OL17003-CCT-CA-1 |
| Kapaċità tal-Fluss tal-Ajru | 160 pied kubu fil-minuta (CFM) |
| Livell ta' Storbju | 1.0 Ħbub |
| Żona ta' Kopertura | Sa 160 pied kwadru |
| Output tad-Dawl | 1500 Lumens (LED) |
| Temperatura tal-Kulur (CCT) | 3000K / 4000K / 5000K (Jista' jintgħażel) |
| Dawl bil-lejl | 2200K |
| Wattage | 40 watts (Fan), 18 watts (Light) |
| Voltage | 120 Volts |
| Sors tal-Enerġija | AC |
| Dimensjonijiet tal-Prodott | 10.59"D x 12.87"W x 7.91"H |
| Daqs tal-Ftuħ tas-Saqaf | 11.81'' x 11.02'' |
| Daqs tal-Katusa | 6 pulzieri |
| Karatteristiċi Speċjali | Humidity Sensor, 3 CCT Selectable, Nightlight |
| Ċertifikazzjonijiet | ETL, FCC, RoHS |
| Tip ta' Installazzjoni | Immonta bil-flus |
| Piż tal-oġġett | 16.87 liri |
Informazzjoni dwar Garanzija
OREiN products are manufactured to high-quality standards. For specific warranty details and terms, please refer to the warranty card included with your product or contact OREiN customer support directly. Keep your proof of purchase for any warranty claims.
Appoġġ għall-Klijent
If you have any questions, require assistance, or need to report an issue with your OREiN product, please contact our customer support team:
- Telefon: 1 (844) 506-1530 (24-Hour Service)
- Online: Fittex għal "OREiN" online to find our official webgħażliet tas-sit u tal-kuntatt.
- Amazon: Contact us directly through your Amazon order details.
When contacting support, please have your product model number (OL17003-CCT-CA-1) and purchase information readily available.