Ledvion LV40015

Ledvion LV40015 150CM 48W 6500K IP65 LED Luminaire Instruction Manual

Mudell: LV40015

1. Introduzzjoni

Thank you for choosing the Ledvion LV40015 LED TL Luminaire. This high-quality LED luminaire is designed for both indoor and outdoor use, featuring a robust, impact-resistant plastic housing and an IP65 rating for protection against dust and water. This manual provides essential information for the safe and efficient installation, operation, and maintenance of your new luminaire.

2. Informazzjoni dwar is-Sigurtà

Jekk jogħġbok aqra l-istruzzjonijiet kollha tas-sigurtà bir-reqqa qabel l-installazzjoni u l-użu. Jekk ma ssegwix dawn l-istruzzjonijiet, dan jista' jirriżulta f'xokk elettriku, nar, jew perikli oħra.

3. X'hemm fil-Kaxxa

Iċċekkja li l-komponenti kollha huma preżenti qabel tibda l-installazzjoni:

Contents of the Ledvion LV40015 box, showing 1x LED Batten, 2x Endcaps, 2x Suspension sets, 1x Plug, 2x Screws, 2x Screw wall plugs, and 1x Manual.

Image: Contents of the Ledvion LV40015 packaging, including the LED luminaire, endcaps, suspension set, plug, screws, wall plugs, and the instruction manual.

4. Setup u Installazzjoni

Follow these steps for proper installation of your Ledvion luminaire.

4.1 Mounting the Luminaire

  1. Agħżel Post: Select a suitable mounting location on a wall or ceiling, ensuring it can support the luminaire's weight (approximately 1.02 kg).
  2. Immarka l-Punti tat-Tħaffir: Use the provided suspension set (mounting brackets) to mark the drilling points for the screws. The luminaire measures 158 cm in length.
  3. Drill toqob: Drill holes at the marked points. Insert the screw wall plugs into the drilled holes.
  4. Waħħal il-parentesi: Securely fasten the suspension set brackets to the mounting surface using the provided screws.
  5. Muntanja Luminarja: Carefully clip the LED luminaire into the installed suspension set brackets. Ensure it is firmly seated.

4.2 Konnessjoni Elettrika

TWISSIJA: Ensure the main power supply is switched off at the circuit breaker before making any electrical connections.

  1. Wajers tal-Aċċess: Iftaħ il-kompartiment tal-wajers tal-luminarja.
  2. Qabbad Wajers: Connect the live (L), neutral (N), and ground (E) wires from your power supply to the corresponding terminals inside the luminaire. Ensure all connections are tight and secure.
  3. Kompartiment Magħluq: Close the wiring compartment, ensuring it is sealed to maintain the IP65 rating.

4.3 Connecting Multiple Luminaires (Toolless Linkable Feature)

This luminaire features a toolless linkable design, allowing you to connect multiple units in series (up to 20 pieces) for extended lighting runs.

Close-up of two Ledvion luminaires showing the toolless linkable connectors on their ends.

Image: Toolless linkable feature, showing how multiple luminaires can be connected directly.

  1. Align Luminaires: Position the luminaires end-to-end.
  2. Qabbad: Simply push the connection plug from one luminaire into the receptacle of the next luminaire until it clicks securely into place.
  3. Tmiem tas-Siġill: Use the provided endcaps to seal the open ends of the connected luminaires to maintain the IP65 rating.
Diagram showing the dimensions of the Ledvion luminaire, with a length of 1500 mm and a width of 63.2 mm.

Image: Product dimensions, indicating a length of 1500 mm and a width of 63.2 mm.

5. Istruzzjonijiet Operattivi

Once installed and connected to the power supply, the Ledvion LV40015 luminaire operates as a standard lighting fixture.

6. Manutenzjoni

Manutenzjoni regolari tiżgura prestazzjoni ottimali u lonġevità tal-lampa tiegħek.

7 Issolvi l-problemi

Jekk tiltaqa' ma' problemi bil-luminarja tiegħek, irreferi għall-problemi u s-soluzzjonijiet komuni li ġejjin:

ProblemaKawża PossibbliSoluzzjoni
Il-luminarja ma tixgħelxNo power supply; Loose wiring; Faulty switchCheck power supply at the circuit breaker; Verify all electrical connections are secure (with power off); Test the switch.
Teptip ħafifUnstable power supply; Loose connectionEnsure stable power source; Check electrical connections.
Produzzjoni ta' dawl imnaqqsaDirt or dust on diffuserClean the luminaire's diffuser with a soft, damp drapp.
Water inside luminaireImproperly sealed endcaps or wiring compartment; Damage to housingImmediately disconnect power. Inspect and reseal endcaps and wiring compartment. If housing is damaged, replace the unit.

If the problem persists after attempting these solutions, contact Ledvion customer support.

8. Speċifikazzjonijiet

Technical details for the Ledvion LV40015 LED TL Luminaire:

Graphic highlighting features of the Ledvion luminaire: Samsung LED chips, 48 Watt power, 6912 Lumen output, and Energy Efficiency Class E.

Image: Key specifications including 48W power, 6912 lumens, and Energy Class E.

Graphic indicating the Ledvion luminaire is water and dust resistant with an IP65 rating, anti-rust, and anti-moisture properties.

Image: IP65 rating details, confirming water and dust resistance.

9. Garanzija u Appoġġ

Ledvion products are manufactured to high-quality standards and come with a manufacturer's warranty. For specific warranty terms and conditions, please refer to the documentation included with your purchase or visit the official Ledvion websit.

If you require technical assistance, have questions about installation, or need to report a defect, please contact Ledvion customer support through the retailer where the product was purchased or via the contact information provided on the Ledvion websit.

Dokumenti Relatati - LV40015

Preview Gwida għall-Installazzjoni u Dejta Teknika tal-Apparat Ledvion IP65 b'Fitting T8
Istruzzjonijiet komprensivi għall-installazzjoni, speċifikazzjonijiet tekniċi, linji gwida dwar is-sigurtà, u informazzjoni dwar il-konformità għall-Apparat Ledvion IP65 b'Fitting T8, li jkopri l-mudelli LV30001 sa LV30006.
Preview Ledvion LVS10013 Dawl tal-Ħajt LED Solari b'Sensor - Manwal tal-Utent
Speċifikazzjonijiet dettaljati, gwida għall-installazzjoni, modi ta' ħidma, u karatteristiċi tad-Dawl tal-Ħajt LED Solari Ultra-Bright Ledvion LVS10013 b'sensor PIR. Jinkludi informazzjoni dwar is-sostituzzjoni tal-batterija u twissijiet ta' sigurtà.
Preview Ledvion LVS10010/LVS10011 Dawl Solari LED ta' Barraamp Manwal u Speċifikazzjonijiet
Manwal tal-utent u speċifikazzjonijiet tekniċi għall-LED solari ta' barra Ledvion LVS10010 u LVS10011amps, li jinkludi sensur tal-moviment, klassifikazzjoni IP65, u dawl abjad sħun ta' 3000K.
Preview Apparat Ledvion IP65 b'Fitting T8: Gwida għall-Installazzjoni u Speċifikazzjonijiet Tekniċi
Istruzzjonijiet dettaljati għall-installazzjoni u dejta teknika għall-apparat Ledvion b'klassifikazzjoni IP65 b'fitting T8. Ikopri n-numri tal-mudelli LV30013-LV30018, vol.tage, frekwenza, protezzjoni, dimensjonijiet, u proċeduri ta' mmuntar pass pass. Jinkludi twissijiet ta' sigurtà u informazzjoni dwar il-konformità.
Preview Manwal tal-Installazzjoni u l-Utent tas-Sokits ta' Barra Ledvion
Dan id-dokument jipprovdi struzzjonijiet dwar l-installazzjoni, l-użu, is-sigurtà, u r-rimi għas-Sokits ta' Barra Ledvion. Jinkludi passi dettaljati għall-immuntar, il-wajers, u t-tħaddim tal-prodott, flimkien ma' twissijiet importanti u linji gwida dwar il-manutenzjoni.
Preview Gwida għall-Installazzjoni u Speċifikazzjonijiet Tekniċi ta' Ledvion LED High Bay Klassi B
Istruzzjonijiet għall-installazzjoni, speċifikazzjonijiet tekniċi, linji gwida dwar is-sigurtà, u konformità CE għal-luminarji Ledvion LED High Bay Klassi B, inklużi l-mudelli LV70061 sa LV70066.