1. Introduzzjoni
Welcome to the user manual for your new ACONEE PC0N 19 SEER Inverter Smart Mini Split AC/Heating System. This manual provides essential information for the safe and efficient operation, installation, and maintenance of your system. Please read it thoroughly before use and retain it for future reference.
2. Informazzjoni dwar is-Sigurtà
Dejjem segwi l-prekawzjonijiet ta' sigurtà li ġejjin biex tevita korriment jew ħsara lill-unità.
Sigurtà Ġenerali
- Ensure the power supply matches the unit's specifications.
- Tippruvax issewwi jew timmodifika l-unità int stess. Ikkuntattja persunal tas-servizz kwalifikat.
- Żomm it-tfal u l-annimali domestiċi 'l bogħod mill-unità waqt it-tħaddim.
Sigurtà Elettrika
- Toperax b'idejn imxarrbin.
- Spluggja l-unità qabel it-tindif jew il-manutenzjoni.
- Żgura ertjar xieraq.
3. Komponenti tal-Prodott
Your ACONEE Mini Split AC/Heating System includes the following main components:
- 1 x Wall mount air handler (Indoor Unit)
- 1 x Outdoor condenser (Outdoor Unit)
- 1 x Pre-flared and insulated copper line set
- 1 x Communication wires
- 1 x Drainage extension with small accessories
- 1 x Kontroll mill-bogħod

Immaġni: Fuqview of the ACONEE Mini Split AC/Heating System, showing the indoor unit, outdoor unit, remote control, and various installation accessories including copper lines, communication wires, and drainage extension.
4. Setup u Installazzjoni
Installation of this mini-split system requires professional knowledge and tools. It is highly recommended to have a certified HVAC technician perform the installation to ensure proper function and safety. Incorrect installation can lead to refrigerant leaks, electrical shock, or fire.
Lista ta' Kontroll ta' Qabel l-Installazzjoni
- Ivverifika l-provvista tal-enerġija voltage (115 Volts).
- Aċċerta ruħek li jkun hemm biżżejjed spazju kemm għall-unitajiet ta' ġewwa kif ukoll għal dawk ta' barra, biex ikun hemm fluss tal-arja xieraq u aċċess għall-manutenzjoni.
- Confirm all included components are present.
- Acquire necessary tools, including a vacuum pump and gauges for line clearing.
Passi ta' Installazzjoni (Fuqview)
- Tqegħid tal-Unità ta' Ġewwa: Select a suitable wall location, ensuring it is strong enough to support the unit's weight and allows for proper air distribution.
- Tqegħid tal-Unità ta' Barra: Choose a stable, level surface outdoors, away from direct sunlight or obstructions, with sufficient clearance for airflow.
- Konnessjoni tas-Sett tal-Linja: Connect the pre-flared copper line set between the indoor and outdoor units. Ensure connections are tight to prevent refrigerant leaks.
- Wiring Elettriku: Connect communication wires and power supply according to the wiring diagram provided in the full installation manual. This step requires a qualified electrician.
- Vacuuming the Lines: Evacuate the refrigerant lines using a vacuum pump to remove air and moisture. This is a critical step for system efficiency and longevity.
- Refrigerant Release: Once lines are vacuumed, release the pre-charged R-32 refrigerant from the outdoor unit into the system.
- Konnessjoni tad-Drenaġġ: Connect the drainage extension to the indoor unit's condensate drain to ensure proper water removal.
- Iċċekkja t-Tnixxija: Perform a thorough leak check on all connections.

Image: A diagram illustrating the dimensions of the indoor and outdoor units, and the connection of the pre-flared and insulated copper line set, communication wires, and drainage extension. This image provides a visual guide for component placement and connection.
5. Istruzzjonijiet Operattivi
Your ACONEE Mini Split system offers multiple operating modes and smart control options.
Metodi ta' Kontroll
- Kontroll mill-bogħod: Use the included wireless remote for direct control of modes, temperature, fan speed, and other functions.
- App għal Smartphone: Download the dedicated app to control the unit remotely via Wi-Fi. This allows control from anywhere with an internet connection.
- Kontroll tal-Vuċi: Compatible with Alexa and Google Assistant for convenient voice commands.

Image: Depicts the smartphone app interface for controlling the ACONEE Mini Split system, alongside an Amazon Echo device, illustrating its compatibility with Alexa for voice control. This highlights the smart control features.
Modi Operattivi
The system features 5 primary working modes:
- Modalità Awtomatika: Automatically selects cooling or heating based on the set temperature and ambient room temperature.
- Modalità Kessaħ: Provides cooling to lower the room temperature. Can cool down to 60°F.
- Modalità tas-Sħana: Provides heating to raise the room temperature. Can heat up to 89°F.
- Modalità Niexfa (Deumidifikazzjoni): Reduces humidity in the room, removing up to 36 pints per day.
- Modalità Fan: Jiċċirkola l-arja mingħajr ma jkessaħ jew isaħħan. Veloċitajiet tal-fann aġġustabbli (Baxxa, Medja, Għolja, Awtomatika).

Image: Illustrates the fast cooling and heating capabilities of the ACONEE Mini Split, showing air flow for cooling down to 60°F and heating up to 89°F. Two individuals are shown comfortably in a room, one using a laptop and the other drinking a beverage, demonstrating the system's effectiveness.
Funzjonijiet Speċjali
- Modalità Sleep: Jaġġusta t-temperatura u l-veloċità tal-fann għal irqad komdu, ħafna drabi jiżdiedasintemperatura g ftit waqt it-tkessiħ jew tnaqqisasing during heating over time. Operates quietly at 27 dB.
- Modalità ECO: Optimizes operation for energy efficiency, reducing power consumption.
- iFEEL Function: Il-kontroll remot għandu sensur tat-temperatura li jippermetti lill-unità taġġusta t-temperatura skont il-post tal-kontroll remot, u b'hekk tipprovdi kumdità aktar preċiża.
- Funzjoni Turbo: Provides rapid cooling or heating to quickly reach the desired temperature.

Image: Shows a person sleeping peacefully, with arrows indicating gentle airflow from the indoor unit. Text highlights the quiet operation at 27 dB and the "Sleep Mode" feature, emphasizing a quiet and cozy environment.
6. Manutenzjoni
Regular maintenance ensures optimal performance and extends the lifespan of your ACONEE Mini Split system.
Tindif tal-filtru
The indoor unit features a washable filter. Clean the filter regularly (e.g., every 2-4 weeks, depending on usage) to maintain air quality and efficiency.
- Iftaħ il-pannell ta 'quddiem tal-unità ta' ġewwa.
- Neħħi l-filtri tal-arja.
- Aħsel il-filtri b'ilma fietel u deterġent ħafif.
- Laħlaħ sewwa u ħallih jinxef kompletament bl-arja qabel ma terġa' ddaħħalh.

Immaġni: Maqtugħ view of the indoor unit showing the "Distributed Healthy Filter System." It highlights the top-opened filter and various healthy filters including Silver Ion, Active Carbon, and Catechin filters, as well as a 6-in-1 filter system (Photocatalyst, Active Carbon, Anti-dust static, Catechin, Silver Ion, Vitamin C). This illustrates the multi-stage filtration for improved air quality.
Funzjoni ta 'Awto-Tindif
The unit has a self-cleaning feature that operates at 134.6°F (57°C) to clean the interior coil and prevent mold and bacteria buildup. Refer to your remote control or app instructions to activate this function.
Outdoor Unit Maintenance
- Keep the area around the outdoor unit clear of debris, leaves, and snow to ensure proper airflow.
- The outdoor unit features automatic defrost to prevent ice buildup in cold weather, increasing energy efficiency.
- Periodically inspect the outdoor coil for dirt and clean gently with water if necessary.
7 Issolvi l-problemi
Qabel ma tikkuntattja l-appoġġ għall-klijenti, jekk jogħġbok irreferi għall-kwistjonijiet u s-soluzzjonijiet komuni li ġejjin:
| Problema | Kawża Possibbli | Soluzzjoni |
|---|---|---|
| L-unità ma tixgħel. | L-ebda provvista tal-enerġija; is-circuit breaker qabad. | Iċċekkja l-konnessjoni tal-enerġija; irrisettja s-circuit breaker. |
| Tkessiħ/tisħin insuffiċjenti. | Dirty air filter; blocked outdoor unit; incorrect mode setting; low refrigerant. | Clean air filter; clear obstructions from outdoor unit; select correct mode; contact technician for refrigerant check. |
| Storbju mhux tas-soltu. | Loose parts; foreign object in fan; unit not level. | Inspect for loose parts; remove foreign objects; ensure unit is level. If noise persists, contact support. |
| Tnixxija ta 'ilma mill-unità ta' ġewwa. | Pajp tad-drenaġġ imblukkat; installazzjoni ħażina. | Check and clear drain pipe; contact installer for inspection. |
| Il-kontroll mill-bogħod ma jaħdimx. | Batteriji mejta; ostruzzjoni bejn ir-remote u l-unità. | Ibdel il-batteriji; neħħi l-ostruzzjonijiet. |
8. Speċifikazzjonijiet
| Karatteristika | Dettall |
|---|---|
| Numru tal-Mudell | PC0N |
| Kapaċità tat-tkessiħ | 9000 BTU (10000 Unità Termali Brittanika) |
| Rating SEER | 19 SEER |
| Voltage | 115 Volts |
| Livell tal-Istorbju (Ġewwa) | 34 dB (as low as 27 dB in Sleep Mode) |
| Tip ta 'Refriġerant | R-32 |
| Dimensjonijiet tal-Prodott (Unità ta' Ġewwa) | 34.84"D x 14.4"W x 10.94"H |
| Piż tal-oġġett | 23.8 liri |
| Żona ta' Kopertura Rakkomandata | Sa 450 pied kwadru |
| Karatteristiċi Speċjali | Inverter Compressor, Remote Controlled, WiFi Enabled, Heating And Cooling Function, Self-Cleaning, Auto Defrost |
9. Garanzija u Appoġġ
ACONEE provides the following warranty and support for your product:
- Garanzija: 2 Snin Garanzija.
- Manutenzjoni: 12 Months Free Maintenance.
- Ritorni: 30 days Unreasonable Return policy.
- Sostituzzjoni tal-Partijiet: Disponibbli.
- Technology Support: Your doubts and questions will be responded to within 24 hours.

Image: Displays information about ACONEE's customer support, including email support within 12 hours, 30 days unreasonable return, and 12 months free maintenance and technology support. This reinforces the brand's commitment to customer service.