This manual provides instructions for the installation, operation, and maintenance of your Anderic CHQ9051T Ceiling Fan Wall Control Remote. This device is designed to control 3-speed ceiling fans and their associated lighting functions. It is compatible with various 3-speed fan receivers, including UC7067FMRX and UC7058RY models. Please read these instructions thoroughly before use to ensure proper function and safety.
2. Informazzjoni dwar is-Sigurtà
- Always disconnect power to the ceiling fan at the circuit breaker before installing or servicing the wall control.
- This wall control is intended for indoor use only.
- Ensure all electrical connections comply with local codes and ordinances. If you are unsure about wiring, consult a qualified electrician.
- Do not expose the wall control to water or excessive humidity.
- Use only the specified battery type (12V A23) for replacement.
- This wall control operates a ceiling fan receiver (not included). Ensure your ceiling fan has a compatible receiver installed.
3. Kontenut tal-Pakkett
Ivverifika li l-oġġetti kollha huma preżenti fil-pakkett tiegħek:
- Anderic CHQ9051T Wall Control Remote
- Parentesi tal-muntaġġ tal-ħajt
- Viti tal-immuntar (2)
Note: A 12V A23 battery is required for operation and is not included in the package. A compatible ceiling fan receiver is also required and sold separately.
4. Setup u Installazzjoni
Follow these steps to install and configure your Anderic CHQ9051T wall control.
4.1. Installazzjoni tal-batterija
- Locate the battery compartment on the back of the wall control.
- Iftaħ l-għatu tal-kompartiment tal-batterija.
- Insert one 12V A23 battery, ensuring correct polarity (+/-).
- Agħlaq l-għatu tal-kompartiment tal-batterija sew.
4.2. Dip Switch Alignment
The wall control communicates with your ceiling fan's receiver via dip switches. These switches must match the pattern set on your ceiling fan's receiver for proper operation.
- Locate the dip switches inside the battery compartment of the wall control.
- Access the dip switches on your ceiling fan's receiver. This usually requires removing the fan's canopy. Refer to your ceiling fan's manual for specific instructions.
- Carefully match the position of the dip switches on the Anderic CHQ9051T wall control to the dip switches on your ceiling fan receiver. Ensure they are an exact match.
- Once matched, replace the battery compartment cover on the wall control and reassemble your ceiling fan canopy.

Immaġni: Wara view of the Anderic CHQ9051T wall control, illustrating the battery compartment and the location of the dip switches for frequency matching.
4.3. Installazzjoni tal-Immonta tal-Ħajt
- Choose a suitable location on your wall for the mount bracket.
- Use the provided screws to secure the wall mount bracket to the wall.
- Slide the Anderic CHQ9051T wall control into the mounted bracket.
5. Istruzzjonijiet Operattivi
The Anderic CHQ9051T wall control provides comprehensive control over your ceiling fan and its lighting. Refer to the image below for button identification.

Immaġni: Quddiem view of the Anderic CHQ9051T wall control, displaying the fan speed, light, and reverse function buttons.
| Buttuna | Funzjoni |
|---|---|
| HI | Tissettja l-veloċità tal-fann għal Għolja. |
| MED | Tissettja l-veloċità tal-fann għal Medja. |
| BAXXA | Tissettja l-veloċità tal-fann għal Baxxa. |
| FAN MITFI | Turns the ceiling fan off. |
| DAWL | Turns the fan light on/off. Press and hold to dim or brighten the light (requires incandescent bulbs for proper dimming). |
| REV | Reverses the direction of the fan blades. This function is typically used to change airflow for seasonal comfort (downward airflow for cooling, upward for heat circulation). |
The wall control operates both downlights and uplights if your fan is equipped with them.
6. Manutenzjoni
6.1. Sostituzzjoni tal-batterija
If the wall control's range decreases or it becomes unresponsive, the battery may need replacement. Follow the steps in Section 4.1 to replace the 12V A23 battery.
6.2. Tindif
Wipe the surface of the wall control with a soft, dry cloth. Do not use abrasive cleaners or solvents, as these can damage the finish or internal components.
7 Issolvi l-problemi
| Problema | Kawża Possibbli | Soluzzjoni |
|---|---|---|
| Fan or light does not respond to wall control. |
|
|
| Lights do not dim properly. | Non-incandescent bulbs are installed. | Replace bulbs with incandescent types for proper dimming functionality. |
| Fan operates intermittently. | Weak battery or interference. | Replace battery. Check for sources of radio frequency interference near the fan or wall control. |
8. Speċifikazzjonijiet
- Isem tal-Mudell: CHQ9051T
- Ditta: Anderiku
- Metodu ta' Kontroll: Remote (Wireless)
- Numru ta' Livelli ta' Qawwa: 3 (Veloċitajiet tal-Fann)
- Sors tal-Enerġija: Battery Powered (1x 12V A23 battery, not included)
- Frekwenza: 303.875 MHz (compatible with CHQ8BT9051T)
- Dimensjonijiet tal-Prodott: 3"D x 1.5"W x 4.5"H
- Piż tal-oġġett: 2.88 uqija
- Tip ta' Installazzjoni: Mount Wall
- Użu fuq ġewwa/barra: Ġewwa
- Riċevituri Kompatibbli: UC7058GM, UC7058RY, UC7067FMRX (receiver not included)
9. Informazzjoni dwar Garanzija
Warranty information for the Anderic CHQ9051T wall control is typically provided with the product packaging or can be obtained directly from the manufacturer. Please retain your proof of purchase for warranty claims.
10. Appoġġ
For technical assistance or further inquiries regarding your Anderic CHQ9051T wall control, please contact Anderic support:
- Websit: www.Anderic.com
- Telefon: 1-855-573-6683
Manifattur: Dan's Electronics Etc., Inc.