1. Prodott Aktarview
The Icron Four-Port USB 3-2-1 Raven 3104 Pro Point-to-Point Extender System is designed to bridge the distance between USB devices and a host computer. This system is optimized for applications requiring extended USB connectivity, such as cameras, video capture devices, remote storage, security and monitoring systems, video matrix systems, and conferencing solutions.
It supports USB 3.2 Gen 1 data rates up to 5 Gb/s and is backward compatible with USB 2.0 and 1.1 devices. The system operates over a single Cat 6a or Cat 7 cable for distances up to 328 feet (100 meters). Comprising a Local Extender (LEX) and a Remote Extender (REX), it also features an integrated Gigabit Ethernet channel with LAN pass-through, allowing network-enabled devices to share the same infrastructure without losing connectivity.
The Raven 3104 Pro offers true plug-and-play functionality, requiring no software drivers, and is compatible with Windows, macOS, Linux, and Chrome OS.
2. Karatteristiċi ewlenin
- USB 3.2 Gen 1 Interface with data rates up to 5 Gb/s.
- Extends USB and Ethernet signals up to 328 feet (100 meters) over a single Cat 6a or Cat 7 cable.
- Supports all USB 3.1, 2.0, and 1.1 devices simultaneously at full bandwidth.
- Features four USB Type-A ports on the Remote Extender (REX).
- Includes a 100/1000 Mb/s Gigabit Ethernet channel with LAN pass-through on both LEX and REX units.
- Supports isochronous USB transactions, crucial for real-time data streams like video.
- True plug-and-play operation; no software drivers required for installation.
- Compatible with major operating systems: Windows, macOS, Linux, and Chrome OS.
- FCC and CE (Class B) compliant.
3. Kontenut tal-Pakkett
The Icron Raven 3104 Pro system typically includes the following components:
- Icron Raven 3104 Pro Local Extender (LEX) unit
- Icron Raven 3104 Pro Remote Extender (REX) unit
- Kejbil USB 3.0
- AC Power Adapter(s)
- Gwida ta' Bidu Mgħaġġel (jew dokumentazzjoni simili)
Note: Cat 6a/7 Ethernet cable is not typically included and must be purchased separately.
4. Setup u Installazzjoni
Follow these steps to set up your Icron Raven 3104 Pro Extender System:
- Pjazzament: Position the Local Extender (LEX) unit near your host computer and the Remote Extender (REX) unit near your USB devices. Ensure both units have access to a power outlet.
- Connect LEX to Host: Connect the supplied USB 3.0 cable from a USB 3.0 port on your host computer to the USB 3.0 port on the LEX unit.
- Connect LEX to REX: Connect a single Cat 6a or Cat 7 Ethernet cable (up to 328 feet / 100 meters) between the RJ45 "LINK" port on the LEX unit and the RJ45 "LINK" port on the REX unit. Ensure the cable is properly terminated and meets Cat 6a or Cat 7 specifications for optimal performance.
- Connect USB Devices to REX: Connect your USB devices (e.g., cameras, storage drives, keyboards, mice) to the available USB Type-A ports on the REX unit. The REX unit provides four USB 3.2 Gen 1 Type-A ports.
- Qabbad l-Enerġija: Connect the AC power adapter(s) to the power input on both the LEX and REX units, then plug them into a power outlet. The Power LED on each unit should illuminate.
- Optional Ethernet Passthrough: If you wish to utilize the Ethernet passthrough feature, connect a network cable from your LAN to the "LAN" port on either the LEX or REX unit. You can then connect another network device to the "LAN" port on the other unit.
Once all connections are made and power is supplied, the system should automatically detect and configure the connected USB devices. No additional drivers are typically required.
Figura 4.1: Dijagramma tal-Konnessjoni tas-Sistema
This diagram illustrates the typical setup of the Icron Raven 3104 Pro system, showing the host computer connected to the Local Extender (LEX), which is then linked to the Remote Extender (REX) via a Cat 6a/7 cable. The REX unit connects to various USB devices, and an optional LAN connection is depicted.
5. Operazzjoni
The Icron Raven 3104 Pro system operates transparently once set up. Connected USB devices will function as if they were directly connected to the host computer.
- Indikaturi tal-Enerġija: Verify that the Power LED on both the LEX and REX units are illuminated, indicating they are receiving power.
- Stat tal-Link: The Link LED on both units should indicate a stable connection over the Cat 6a/7 cable. Refer to the device's specific LED behavior for detailed status (e.g., solid green for active link).
- Rikonoxximent ta' Apparat USB: Your operating system should automatically detect and install drivers for the connected USB devices, similar to direct connection.
- Trasferiment tad-Data: Data transfer rates up to 5 Gb/s (USB 3.2 Gen 1) are supported, allowing for high-bandwidth applications like uncompressed video streaming or large file trasferimenti.
- Passthrough Ethernet: If the LAN ports are utilized, network connectivity will be available at both ends of the extender system.
Figure 5.1: Front Panel of Extender Units
This image displays the front panels of the Icron Raven 3104 Pro units, highlighting the power indicator, mode button, and configuration button, along with status LEDs for USB link activity.
Figure 5.2: Rear Panel of Extender Units
This image shows the rear panels of the Icron Raven 3104 Pro units, detailing the various connectivity options including USB Type-A ports for devices, a USB Type-B port for host connection, LAN ports for network passthrough, and the dedicated link ports for the Cat 6a/7 cable connection between the LEX and REX units.
6. Manutenzjoni
The Icron Raven 3104 Pro Extender System is designed for minimal maintenance. Follow these guidelines to ensure optimal performance and longevity:
- Tindif: Uża drapp artab u niexef biex tnaddaf il-barra tal-unitajiet. Tużax prodotti tat-tindif likwidi jew aerosol.
- Ventilazzjoni: Ensure that the ventilation slots on the units are not blocked to prevent overheating. Maintain adequate airflow around the devices.
- Ġestjoni tal-Kejbil: Ensure all cables (USB, Ethernet, power) are securely connected and not under undue strain. Avoid sharp bends or kinks in the Cat 6a/7 cable.
- Aġġornamenti tal-Firmware: Periodically check the Icron website for any available firmware updates for your model. Follow the instructions provided by the manufacturer for any update procedures.
- Kundizzjonijiet Ambjentali: Operate the units within their specified temperature and humidity ranges. Avoid extreme temperatures or high humidity environments.
7 Issolvi l-problemi
If you encounter issues with your Icron Raven 3104 Pro system, refer to the following troubleshooting steps:
7.1. No Power / Units Not Turning On
- Verify that the power adapters are securely connected to both the LEX and REX units and to a working power outlet.
- Iċċekkja jekk is-sokit tal-enerġija huwiex attiv billi tqabbad apparat ieħor.
- Ensure you are using the original power adapters supplied with the system.
7.2. USB Devices Not Detected or Functioning
- Check Link Status: Ensure the Cat 6a/7 cable is properly connected between the LEX and REX units and that the Link LEDs on both units indicate a stable connection.
- Kwalità tal-Kejbil: Verify that the Cat 6a/7 cable meets specifications and is not damaged. A faulty or low-quality cable can cause connectivity issues.
- Kejbil USB: Ensure the USB 3.0 cable connecting the LEX to the host computer is secure and functional. Try a different USB port on the host.
- Ċiklu tal-Enerġija: Disconnect power from both LEX and REX units, wait 10 seconds, then reconnect power. Restart your host computer.
- Test tal-Konnessjoni Diretta: Connect the USB device directly to the host computer to confirm the device itself is functional.
- USB Port on REX: Try connecting the USB device to a different USB port on the REX unit.
- Rekwiżiti tal-Enerġija: Some high-power USB devices may require external power or a powered USB hub connected to the REX unit.
7.3. Slow USB Performance
- Kwalità tal-Kejbil: Ensure you are using a high-quality Cat 6a or Cat 7 cable. Lower category cables or damaged cables can significantly impact performance.
- Tul tal-Cable: While the system supports up to 328 feet, extremely long runs with lower quality cables might experience some degradation.
- Host USB Port: Ensure the LEX unit is connected to a USB 3.0 (or higher) port on your host computer to achieve USB 3.2 Gen 1 speeds.
- Kompatibbiltà tal-Apparat: Confirm that the connected USB device is capable of USB 3.0/3.1/3.2 speeds.
7.4. Ethernet Passthrough Issues
- Konnessjonijiet tal-kejbil: Verify that the Ethernet cables are securely connected to the "LAN" ports on both units and to your network devices.
- Konfigurazzjoni tan-Netwerk: Ensure your network devices are properly configured (e.g., correct IP addresses, DHCP settings).
- Stat tal-Link: Check the LAN port LEDs on the extender units and connected network devices for link activity.
8. Speċifikazzjonijiet
| Attribut | Dettall |
|---|---|
| Numru tal-Mudell | 3104 PRO |
| Brand | Iron |
| USBStandard | USB 3.2 Gen 1 (backward compatible with USB 2.0/1.1) |
| Rata tad-Data | Sa 5 Gb/s |
| Distanza ta' Estensjoni | Sa 328 pied (100 metri) |
| Tip ta' Cable | Single Cat 6a or Cat 7 Ethernet cable |
| Remote Extender (REX) Ports | 4 x USB Type-A (USB 3.2 Gen 1) |
| Local Extender (LEX) Port | 1 x USB Type-B (USB 3.2 Gen 1) for host connection |
| Portijiet Ethernet | 1 x Gigabit Ethernet RJ45 (LAN) on each unit |
| Interface tal-Ħardwer | Ethernet, USB, USB 2.0, USB 3.0 |
| Apparati Kompatibbli | USB Devices (Keyboards, Mice, Storage Devices, Cameras, etc.), Network-Enabled Devices |
| Sistemi Operattivi | Windows, macOS, Linux, Chrome OS |
| Piż tal-oġġett | 7.28 pounds (system) |
| Dimensjonijiet tal-Pakkett | 10.5 x 8.5 x 7 pulzieri |
9. Garanzija u Appoġġ
Specific warranty terms and support contact information are typically provided with your product packaging or available on the manufacturer's official website. For the most up-to-date information regarding warranty coverage, technical support, and service, please visit the Iron websit jew ikkuntattja lis-servizz tal-konsumatur tagħhom direttament.
When contacting support, please have your product model number (3104 PRO) and serial number ready.





