ProCom MN180TPA-B

ProCom MN180TPA-B Natural Gas Ventless Infrared Plaque Heater User Manual

Model: MN180TPA-B

Introduzzjoni

This manual provides essential information for the safe and efficient operation of your ProCom MN180TPA-B Natural Gas Ventless Infrared Plaque Heater. Please read all instructions carefully before installation, operation, or maintenance. Retain this manual for future reference.

ProCom MN180TPA-B Natural Gas Ventless Infrared Plaque Heater

Immaġni: Quddiem view of the ProCom MN180TPA-B Natural Gas Ventless Infrared Plaque Heater, showcasing its compact design and infrared heating plaques.

Informazzjoni dwar is-Sigurtà

Your ProCom heater is designed with safety in mind. It is a ventless unit, meaning it does not require an outside duct or chimney. However, proper ventilation is still crucial for safe operation. This heater is equipped with an Oxygen Depletion Sensor (ODS) that automatically shuts down the unit if oxygen levels become too low. It is ANSI Certified to ensure safety standards are met.

Karatteristiċi tal-Prodott

ProCom MN180TPA-B Features Diagram

Image: Diagram highlighting key features of the ProCom heater, including BTU output, ventless operation, natural gas compatibility, no electricity requirement, safety features, Piezo ignition, and thermostat mode.

Setup

The ProCom MN180TPA-B heater offers flexible installation options: wall-mounted or floor-standing.

Spakkjar u Spezzjoni

Għażla ta' Post

Select a location that allows for proper clearances from combustible materials. Ensure the area has adequate ventilation as per local codes and the heater's specifications.

Għażliet ta 'Installazzjoni

Bil-wieqfa fl-art: Attach the included base feet to the bottom of the heater using the provided hardware. Ensure the heater is stable and level.

Immuntar tal-ħajt: Use the included wall mounting bracket and hardware. Follow the detailed instructions in the manufacturer's full installation guide for secure wall attachment and proper clearances.

ProCom MN180TPA-B Included Components

Image: Components included with the ProCom heater, showing the main unit, base feet, wall bracket, and highlighting the Oxygen Depletion Sensor and natural gas operation.

ProCom MN180TPA-B Wall Mounted

Image: The ProCom MN180TPA-B heater mounted on a wall in a living space, demonstrating its compact profile and integration into a room.

Konnessjoni tal-Gass

This heater operates on natural gas only. Connection to the natural gas supply must be performed by a qualified professional in accordance with all local codes and regulations. Ensure all connections are leak-tested before operation.

Istruzzjonijiet Operattivi

Follow these steps to safely operate your ProCom MN180TPA-B heater.

Proċedura ta' Tqabbid

  1. Kun żgur li l-valv tal-provvista tal-gass ikun miftuħ.
  2. Turn the control knob to the 'PILOT' position.
  3. Press and hold the control knob in while simultaneously pressing the Piezo ignition button repeatedly until the pilot flame ignites.
  4. Continue to hold the control knob in for approximately 30-60 seconds after the pilot ignites to allow the thermocouple to heat up. Release the knob; the pilot should remain lit.
  5. If the pilot does not remain lit, repeat steps 2-4.
  6. Once the pilot is stable, turn the control knob to the desired heat setting (1-5). The main burner will ignite.

Kontroll tat-termostat

The heater features a thermostat control with 5 variable heat settings. Rotate the control knob to select your preferred heat output. The heater will cycle on and off to maintain the set temperature.

ProCom MN180TPA-B Thermostat Controls

Immaġni: Close-up view of the control panel on the ProCom heater, showing the Piezo ignitor button and the rotary knob for 5 variable heat settings and pilot control.

Shutting Down the Heater

  1. Dawwar il-pum tal-kontroll għall-pożizzjoni 'MITFI'.
  2. For prolonged shutdown, close the main gas supply valve to the heater.

Manutenzjoni

Manutenzjoni regolari tiżgura l-lonġevità u t-tħaddim sikur tal-ħiter tiegħek.

Issolvi l-problemi

If you encounter issues with your heater, refer to the following common problems and solutions. For persistent issues, contact a qualified service technician.

ProblemaKawża PossibbliSoluzzjoni
Il-pilota mhux se jixgħelNo gas supply; Air in gas line; Pilot orifice clogged; Faulty thermocoupleCheck gas supply; Purge air from line; Clean pilot orifice; Contact technician
Pilot lights but will not stay litThermocouple not heating sufficiently; Loose thermocouple connection; Faulty ODS pilot assemblyHold knob longer; Tighten connection; Contact technician
Main burner will not ignitePilot not lit; Main burner orifice clogged; Low gas pressureEnsure pilot is lit; Clean burner orifice; Contact gas provider/technician
Heater cycles off frequentlyInsufficient ventilation; ODS activation; Thermostat setting too high for room sizeIncrease ventilation; Check for obstructions; Adjust thermostat setting

Speċifikazzjonijiet

AttributDettall
BrandProCom
Numru tal-MudellMN180TPA-B
Tip ta' FjuwilGass Naturali
Maximum BTU Output18,000 BTU
Kopertura tat-TisħinSa 950 pied kwadru.
Tip ta 'TqabbidPush Button Piezo
Tip ta' KontrollThermostat (High/Medium/Low)
Karatteristiċi tas-SigurtàOxygen Depletion Sensor (ODS)
Għażliet ta 'ImmuntarWall Mount, Floor Standing (Base Feet Included)
Dimensjonijiet tal-Prodott8"D x 22"W x 26"H
Piż tal-oġġett26.2 liri
KulurAbjad
ĊertifikazzjonijietCSA Certified, ANSI Certified
ProCom MN180TPA-B Dimensions Diagram

Image: Diagram illustrating the dimensions of the ProCom MN180TPA-B heater: 24 inches H, 19 inches L, and 8 inches D.

Informazzjoni dwar Garanzija

For detailed warranty information regarding your ProCom MN180TPA-B Natural Gas Ventless Infrared Plaque Heater, please refer to the warranty card included with your product packaging or visit the official ProCom websit. It-termini u l-kundizzjonijiet tal-garanzija jistgħu jvarjaw.

Appoġġ għall-Klijent

If you require assistance, have questions about your heater, or need to report an issue, please contact ProCom customer support. Refer to your product packaging or the official ProCom website for the most current contact information, including phone numbers, email addresses, and online support resources.

Dokumenti Relatati - MN180TPA-B

Preview Manwal tal-Utent tar-Radju 2-Way tal-Banda taċ-Ċittadini Procom PRO-9900 AM/FM ĠDID
Manwal tal-utent għar-Radju 2-Way Procom NEW PRO-9900 AM/FM Citizens Band, li jiddeskrivi l-funzjonijiet, l-operazzjonijiet, il-karatteristiċi u l-ispeċifikazzjonijiet tekniċi tiegħu għal użu ottimali.
Preview PROCOM Atlas Loud Mouth Digital Wireless Intercom User Manual
This user manual provides comprehensive information on the PROCOM Atlas Loud Mouth Digital Wireless Intercom, including its features, operation, specifications, safety guidelines, and FCC compliance.
Preview ProCom Heating Vent-Free Gas Space Heater: Operation and Installation Manual
Comprehensive guide for ProCom Heating vent-free gas space heaters, covering installation, operation, safety, maintenance, and troubleshooting for models MN180TPA-B, ML150TPA-B, MN300TPA-B, and ML250TPA-B.
Preview Manwal tas-Sid għat-Tħaddim u l-Installazzjoni tal-Heater tal-Ħajt tal-Gass mingħajr Vent ProCom
Dan il-manwal jipprovdi struzzjonijiet dwar it-tħaddim u l-installazzjoni għall-ProCom Vent-Free Gas Wall Heaters, inklużi l-mudelli MN2PHG, MN2PTG, MN3PHG, MN3PTG, ML2PHG, ML2PTG, ML3PHG, u ML3PTG. Ikopri l-prekawzjonijiet ta' sigurtà, il-karatteristiċi tal-prodott, l-ispeċifikazzjonijiet, il-proċeduri ta' installazzjoni, it-tħaddim, is-soluzzjoni tal-problemi, il-partijiet, l-aċċessorji, u informazzjoni dwar il-garanzija.
Preview Lista ta' Spare Parts tal-Unità ta' Ġewwa Bosch Climate 5000AA Series
Lista dettaljata tal-ispare parts u dijagramma għall-Unità Interna Bosch Climate 5000AA Series, inklużi n-numri tal-partijiet u informazzjoni dwar il-kompatibilità għal diversi kapaċitajiet BTU.
Preview Manwal tal-Heater tal-Log tal-Gass mingħajr Ventilazzjoni ProCom Heating
Dan il-manwal jipprovdi struzzjonijiet komprensivi dwar l-installazzjoni, it-tħaddim, is-sigurtà u l-manutenzjoni għall-mudelli ProCom Heating Vent-Free Gas Log Heater PCNSD18T, PCNSD24TD, u PCNSD24M. Tgħallem kif tinstalla u tuża l-gas log heater tiegħek b'mod sigur.