ALLmeter B0C4SRMFMD

Multimetru Diġitali tat-Tip ta' Pinna ALLmeter AC VoltagManwal tal-Istruzzjonijiet tal-e Tester (Mudell B0C4SRMFMD)

1. Introduzzjoni

This manual provides detailed instructions for the safe and effective use of your ALLmeter Pen Type Digital Multimeter, Model B0C4SRMFMD. This device is designed for measuring AC/DC voltage, resistance, diode, and continuity. It also features non-contact voltage (NCV) detection and live wire identification. Please read this manual thoroughly before operation and retain it for future reference.

2. Informazzjoni dwar is-Sigurtà

WARNING: Electrical shock hazard. Improper use of this meter can cause injury or death. Follow all safety precautions.

  • Always ensure the meter is in good working condition before use. Inspect for any damage to the casing or test leads.
  • Tippruvax tkejjel il-voltages jew kurrenti li jaqbżu l-limiti massimi speċifikati.
  • Exercise extreme caution when working with live circuits. Always assume circuits are live until verified otherwise.
  • Ilbes tagħmir protettiv personali (PPE) xieraq, bħal nuċċalijiet tas-sigurtà u ingwanti iżolati.
  • Do not use the meter in wet environments or if your hands are wet.
  • Kun żgur li l-kompartiment tal-batterija jkun magħluq sew qabel l-operazzjoni.
  • This device is designed for AC voltage detection in NCV mode and cannot measure DC current.

3. Prodott Aktarview

Familiarize yourself with the components of your ALLmeter Pen Type Digital Multimeter:

Diagram of ALLmeter Pen Type Digital Multimeter with labeled parts

Figura 3.1: Labeled diagram of the ALLmeter Pen Type Digital Multimeter. Key components include the Input COM, Portable pen hook, Select key, HOLD key, N/L/P key, Display LCD, Signal strength indicator, LED light, and Test pen tip.

4. Setup

4.1 Installazzjoni tal-batterija

The ALLmeter Pen Type Digital Multimeter requires one AAA battery (included). To install or replace the battery:

  1. Locate the battery compartment cover, typically at the rear or top of the device.
  2. Iftaħ il-qoxra.
  3. Daħħal batterija AAA waħda, waqt li tiżgura l-polarità korretta (+/-).
  4. Agħlaq l-għatu tal-kompartiment tal-batterija sew.

The device includes a low-battery indicator on the LCD display to signal when replacement is needed.

5. Istruzzjonijiet Operattivi

5.1 Power On/Off

Press the 'Select' button to power on the device. The device will automatically power off after 15 minutes of inactivity to conserve battery life.

5.2 Automatic Measurement Function

In automatic mode, the meter intelligently detects the type of measurement (DC/AC voltage or resistance) and displays the value. This simplifies the measurement process by eliminating the need to manually select ranges.

LCD display showing automatic AC, DC voltage, and resistance measurements

Figura 5.1: Examples of automatic measurement displays for AC voltage, DC voltage, and resistance (Ohm).

5.3 Manual Functions (Electric Field and Live Wire Detection)

Pressing the 'N/L' button cycles through additional functions. Note that in these modes, only AC can be measured, not DC.

LCD display showing EF for Electric Fields and LIVE for live wire detection

Figura 5.2: Displays for Electric Field (EF) and Live Wire (LIVE) detection modes.

  • EF (Electric Fields): This mode detects electric fields without requiring a ground wire. Bring the tip close to a wire to detect if it is live.
  • LIVE (Live Wire): In this mode, the device functions as an AC detector. Touch the tip to a wire, and it will beep if the wire is live.

5.4 Kejl tad-diode

To measure a diode:

  1. Press the 'Select' button repeatedly until the diode symbol appears on the screen.
  2. Connect the test leads to the diode.
Hand holding the multimeter to measure a diode on a circuit board

Figura 5.3: Measuring a diode on a circuit board using the multimeter.

5.5 Test ta' Kontinwità

The continuity test checks for an unbroken path in a circuit. If a continuous path is detected, the meter will emit an audible beep.

5.6 Vol. Mingħajr Kuntatttage (NCV) Sejbien

The NCV feature allows for safe detection of AC voltage without direct contact. The device will indicate the presence of AC voltage within a range of 12V-1000V. In NCV mode, it can only detect alternating current (AC) and cannot measure direct current (DC).

Multimeter being used for non-contact voltage detection in a dimly lit electrical panel, with its LED light on

Figura 5.4: Using the NCV function and LED light in a low-light environment.

5.7 Data Hold (HOLD Key)

Agħfas il-buttuna 'HOLD' biex tiffriża l-qari attwali fuq id-displej. Agħfasha mill-ġdid biex tirrilaxxa l-funzjoni hold.

5.8 Linterna LED

The built-in LED light can be activated to illuminate dimly lit work areas. Refer to the product overview for the location of the LED light.

6. Applikazzjonijiet

The ALLmeter Pen Type Digital Multimeter is suitable for various electrical testing scenarios:

Two images: top shows testing an electrical outlet, bottom shows testing a circuit breaker panel

Figura 6.1: Examples of multi-function usage, including testing electrical outlets and circuit breaker panels.

Hand using the multimeter to test components in a car engine bay

Figura 6.2: Testing electrical components within a car engine.

7. Speċifikazzjonijiet

KaratteristikaSpeċifikazzjoni
MudellB0C4SRMFMD
WiriLCD, 6000 Counts
AC / DC Voltage FirxaAutomatic scanning test (DC/AC 6V, 60V, 600V)
Firxa tar-reżistenza6kΩ, 60kΩ, 600kΩ, 6MΩ, 60MΩ
Mhux Kuntatt Voltage (NCV) Sejbien12V-1000V AC
Sors tal-Enerġija1 x Batterija AAA (inkluża)
Auto Power Mitfi15 minuti ta 'inattività
Dimensjonijiet8.11 x 2.24 x 1.34 pulzieri
Piż4.23 uqija
KulurIswed

8. Manutenzjoni

  • Tindif: Imsaħ il-miter b'ċarruta niexfa u ratba. Tużax prodotti tat-tindif jew solventi li joborxu.
  • Ħażna: When not in use for extended periods, remove the battery to prevent leakage. Store the meter in a cool, dry place, away from direct sunlight and extreme temperatures.
  • Sostituzzjoni tal-batterija: Replace the AAA battery when the low-battery indicator appears on the display.

9 Issolvi l-problemi

ProblemaKawża PossibbliSoluzzjoni
Il-miter ma jixgħelxBatterija mejta jew installata ħażinCheck battery polarity or replace with a new AAA battery.
Qari mhux eżattLow battery; incorrect mode selection; environmental interferenceReplace battery; ensure correct mode is selected; move away from strong electromagnetic fields.
NCV mode not detecting DCNCV mode is designed for AC onlyThis is normal operation. The NCV mode only detects alternating current (AC).
Display shows 'OL'Overload or open circuitThe measured value exceeds the range, or there is no connection. Check the circuit or range.

10. Kontenut tal-Pakkett

The ALLmeter Pen Type Digital Multimeter package includes:

  • ALLmeter Pen Type Digital Multimeter
  • 1.5V Batterija AAA
  • Ċomb tat-Test
Image of the test lead included with the multimeter

Figura 10.1: The included test lead for various measurements.

11. Garanzija u Appoġġ

For warranty information or technical support, please refer to the documentation provided with your purchase or contact ALLmeter customer service directly. Contact details are typically available on the manufacturer's official webis-sit jew l-imballaġġ tal-prodott.

Dokumenti Relatati - B0C4SRMFMD

Preview Manwal tal-Utent tal-Multimetru Intelliġenti tat-Tip Pinna ALLmeter 6000 Counts
Manwal tal-utent għall-multimetru intelliġenti tat-tip pinna ALLmeter 6000 Counts. Ikopri aktar minnview, prekawzjonijiet ta' sigurtà, karatteristiċi ġenerali u tekniċi, deskrizzjoni tal-pannell tal-operazzjoni, indikaturi tekniċi għal DCV/ACV, reżistenza, u kejl tad-dijodi, issolvi l-problemi, u informazzjoni dwar il-garanzija.
Preview Manwal tal-Utent tal-Miter tal-Umdità Induttiv mingħajr Pinnijiet
Istruzzjonijiet u speċifikazzjonijiet għall-ALLmeter Pinless Inductive Moisture Meter, strument mhux invażiv għall-kejl tal-kontenut ta' umdità fil-ħitan, fil-ġebel, fl-injam artab, u fl-injam iebes. Jinkludi karatteristiċi, speċifikazzjonijiet tekniċi, preċiżjoni, tħaddim, u tabelli tad-densità tal-injam.