OWON XSA805-TG

Manwal tal-Utent tal-Analizzatur tal-Ispettru OWON XSA805-TG

Model: XSA805-TG

1. Introduzzjoni

This manual provides comprehensive instructions for the OWON XSA805-TG Spectrum Analyzer. It covers the device's features, setup, operation, and maintenance to ensure safe and efficient use. The XSA805-TG is a high-performance spectrum analyzer designed for various signal analysis applications, featuring a 9-inch LCD, a frequency range of 9 kHz to 500 MHz, and a tracking generator.

2. Informazzjoni dwar is-Sigurtà

Please read all safety instructions carefully before operating the device. Failure to follow these instructions may result in injury or damage to the instrument.

  • Provvista tal-Enerġija: Uża biss l-adapter tal-enerġija speċifikat. Kun żgur li s-sors tal-enerġija jaqbel mal-volumtage requirements of the instrument.
  • Ambjent: Operate the device in a dry, well-ventilated area. Avoid exposure to extreme temperatures, humidity, dust, or corrosive gases.
  • Ventilazzjoni: Do not block the ventilation openings on the instrument. Adequate airflow is essential to prevent overheating.
  • Konnessjonijiet: Ensure all connections are secure before powering on the device. Disconnect power before making or changing connections.
  • Servizzi: Tippruvax tagħmel manutenzjoni tal-istrument int stess. Irreferi għal kull manutenzjoni għand persunal tas-servizz kwalifikat.
  • Tindif: Clean the instrument with a soft, dry cloth. Do not use liquid or aerosol cleaners.

3. Prodott Aktarview

The OWON XSA805-TG Spectrum Analyzer is equipped with a 9-inch LCD and various interfaces for comprehensive signal analysis. Below are the key components and their functions.

3.1 Panel ta 'Quddiem

OWON XSA805-TG Front Panel Layout

The front panel features the main display, control buttons, numeric keypad, and input/output ports.

  • Menu Softkeys: Context-sensitive buttons for menu navigation.
  • Ċwievet tal-Funzjoni: Dedicated buttons for common functions like SPAN, RBW, Trace, etc.
  • Pum: Rotary encoder for adjusting parameters and navigating menus.
  • Ċwievet tal-vleġeġ: For precise cursor movement and parameter selection.
  • Tastiera numerika: For direct entry of numerical values.
  • Ċavetta tal-Enerġija: Biex tixgħel jew titfi l-apparat.
  • USB Host Interface: For connecting USB storage devices or other peripherals.
  • Interface tal-widna: Għall-output tal-awdjo.
  • Tracking Generator Output (optional): Output for the tracking generator function.
  • RF Input Connector: Main input for RF signals.

3.2 Panel ta 'wara

OWON XSA805-TG Rear Panel Layout

The rear panel provides additional connectivity options and power input.

  • Interfaċċja HDMI: For connecting an external display.
  • Interface tal-Apparat USB: For connecting the analyzer to a computer.
  • Trigger Input Connector: For external trigger signals.
  • Reference Clock In/Out: For external clock synchronization.
  • Interface LAN: Għall-konnettività tan-netwerk.
  • Konnettur tal-Enerġija AC: Għall-konnessjoni tal-korda tal-enerġija.
  • Security Lock Hole: Għall-iżgurar tal-apparat.

4. Setup

Follow these steps to set up your OWON XSA805-TG Spectrum Analyzer.

  1. Spakkjar: Carefully remove the spectrum analyzer and all accessories from the packaging. Inspect for any signs of damage.
  2. Konnessjoni tal-Enerġija: Connect the provided AC power cord to the AC Power Connector on the rear panel and then to a suitable power outlet.
  3. Qawwa Inizjali Mixgħula: Press the Power Key on the front panel to turn on the device. The system will boot up and display the main measurement interface.
  4. External Connections (Optional):
    • Apparat USB: Connect USB storage or other peripherals to the USB Host Interface.
    • Konnessjoni tal-Kompjuter: Use a USB cable to connect the USB Device Interface to your computer for data transfer or remote control.
    • Display Estern: Connect an HDMI cable to the HDMI Interface for an external monitor.
    • Netwerk: Connect an Ethernet cable to the LAN Interface for network access.

5. Istruzzjonijiet Operattivi

This section details the primary functions and operational modes of the XSA805-TG Spectrum Analyzer.

5.1 Kejl Bażiku

Upon startup, the analyzer displays the default spectrum measurement screen. Use the function keys and softkeys to adjust parameters such as Center Frequency, Span, Resolution Bandwidth (RBW), and Video Bandwidth (VBW).

  • Frekwenza taċ-Ċentru: Sets the center frequency of the displayed spectrum.
  • Ispan: Defines the frequency range displayed around the center frequency.
  • RBW (Resolution Bandwidth): Determines the frequency resolution of the measurement. A smaller RBW provides better resolution but increases sweep time.
  • VBW (Video Bandwidth): Controls the bandwidth of the video filter, affecting trace smoothing.

5.2 Quick Capture Function

The quick capture function allows for rapid analysis of ASK/FSK modulated signals, directly providing center frequency, power, and offset parameters. This is particularly useful for analyzing signals from devices like car remote keys, TRMS tire pressure modules, and small wireless modules.

Quick Capture Function Overview

The image above illustrates the application of the quick capture function for various wireless devices.

Quick Capture Function Detail

This image highlights the 1 Hz minimum resolution bandwidth (RBW) capability, which effectively distinguishes nearby signals, crucial for detailed analysis in quick capture mode.

5.3 Extended Function Modes

The XSA805-TG offers multiple extended function modes for advanced analysis, including modulation signal quality analysis, audio demodulation, field strength measurement, channel measurement, and frequency counter.

Extended Function Modes Overview

The image above shows the interface for modulation signal quality analysis and audio demodulation.

Extended Function Modes Detail

This image displays the interfaces for channel measurement and the frequency counter, demonstrating the versatility of the analyzer.

5.4 EMI Test Function (Optional Software Required)

The device supports EMI pre-compliance testing with an optional software package. It includes over 200 mainstream EMC test standards and regulation templates. This allows users to select corresponding templates, and the software automatically configures the spectrum analyzer and records test data. Data and regulations can be compared on the same screen, and users can customize regulations for comparative analysis.

EMI Test Function Interface

The image illustrates the EMI test software interface, showing measurement parameters and a graphical display of test results.

6. Speċifikazzjonijiet

The following table outlines the key technical specifications for the OWON XSA805-TG Spectrum Analyzer.

OWON XSA800 Series Spectrum Analyzer Specifications Table

This image provides a detailed comparison of specifications across the XSA800 series, including the XSA805-TG model.

Speċifikazzjonijiet Ġenerali
KaratteristikaSpeċifikazzjoni
Dimensjonijiet tal-Prodott20.28 x 10.43 x 13.78 pulzieri
Piż11.02 Liri
Wiri9-inch LCD, 1280x800 Pixels
Medda ta' Frekwenzi9 kHz - 500 MHz
Displayed Average Noise Level (DANL)-160 dBm
Stadju tal-Fażi-80 dBc/Hz @ 1 GHz and offset at 10 kHz
Minimum Resolution Bandwidth (RBW)1 Hz
InterfacesUSB Host, USB Device, LAN, Earphone, HDMI

7. Manutenzjoni

Proper maintenance ensures the longevity and optimal performance of your spectrum analyzer.

  • Tindif: Regularly clean the exterior of the instrument with a soft, dry, lint-free cloth. Do not use abrasive cleaners or solvents. For the display, use a screen-specific cleaner if necessary, applied to the cloth, not directly to the screen.
  • Ħażna: When not in use, store the analyzer in a clean, dry environment, away from direct sunlight and extreme temperatures. Use the original packaging or a protective case if available.
  • Kalibrazzjoni: For critical measurements, periodic calibration by qualified service personnel is recommended to maintain accuracy.
  • Aġġornamenti tas-Software: Check the OWON official website for any available firmware or software updates to ensure your device has the latest features and bug fixes.

8 Issolvi l-problemi

This section provides solutions to common issues you might encounter with your OWON XSA805-TG.

ProblemaKawża PossibbliSoluzzjoni
L-apparat ma jixgħelxPower cord not connected; Power outlet faulty; Device fault.Check power cord connection; Test power outlet; Contact support if issue persists.
Ebda sinjal muriInput signal cable disconnected; Input signal too weak; Incorrect frequency settings.Verify signal cable connection; Ensure signal source is active; Adjust Center Frequency and Span.
Screen frozen or unresponsiveSoftware error; Temporary glitch.Restart the device by holding the power button; If persistent, check for firmware updates.
Apparat USB mhux rikonoxxutUSB device incompatible; Faulty USB port.Try a different USB device; Use a different USB port; Ensure device is formatted correctly.

If you encounter problems not listed here or if the suggested solutions do not resolve the issue, please contact OWON customer support.

9. Garanzija u Appoġġ

OWON provides a limited warranty for its products. Please refer to the warranty card included with your product or visit the official OWON websit għal termini u kundizzjonijiet dettaljati tal-garanzija.

For technical support, service, or inquiries, please contact OWON customer service through the following channels:

  • OWON Official Websit: www.owon.com (Check for support contact information, FAQs, and software downloads)
  • Ċentri tas-Servizzi Awtorizzati: A list of authorized service centers may be available on the OWON websit.

When contacting support, please have your product model number (XSA805-TG) and serial number ready.

Dokumenti Relatati - XSA805-TG

Preview Руководство пользователя анализатора спектра OWON XSA815-TG с генератором слежения
Данное руководство пользователя содержит подробные инструкции и спецификации для анализатора спектра OWON XSA815-TG с генератором слежения, охватывая настройку, эксплуатацию, измерения и устранение неполадок.
Preview Manwal tal-Utent tal-Analizzatur tal-Ispettru li jinżamm fl-idejn tas-Serje Owon HSA1000
Manwal tal-utent għall-Analizzatur tal-Ispettru li jinżamm fl-idejn tas-Serje Owon HSA1000, li jagħti dettalji dwar l-ispeċifikazzjonijiet, it-tħaddim, il-prekawzjonijiet ta' sigurtà, u s-soluzzjoni tal-problemi għall-mudelli HSA1016, HSA1016-TG, HSA1036, HSA1036-TG, HSA1075, u HSA1075-TG.
Preview Owon SDS1102+ Digital Oscilloscope with Function Generator
Detailed specifications and features of the Owon SDS1102+ Digital Oscilloscope, including its bandwidth, sampling rate, record length, automatic measurements, and waveform generator capabilities. The document also lists included accessories.
Preview Gwida Rapida tas-Serje OWON FDS: Manwal tal-Utent u Istruzzjonijiet għat-Tħaddim
Get started with your OWON FDS Series oscilloscope. This quick guide covers essential setup, safety, and operational details for its oscilloscope, function generator, power supply, and multimeter features. Visit www.owon.com.hk/download for full support.
Preview OWON HDS200 Series SCPI Command Protocol Reference
This document details the Standard Commands for Programmable Instruments (SCPI) protocol for the OWON HDS200 Series oscilloscopes, covering horizontal settings, acquisition, channel configuration, triggering, measurements, and function generator control.
Preview Speċifikazzjonijiet Tekniċi tal-Oxxilloskopju Diġitali tas-Serje Owon FDS
Speċifikazzjonijiet tekniċi dettaljati għall-oxxilloskopji diġitali tas-Serje Owon FDS, inklużi l-mudelli FDS1102 u FDS1102A, li jkopru l-karatteristiċi tal-prestazzjoni, il-funzjonijiet tat-trigger, il-ġenerazzjoni tal-forma tal-mewġa, il-provvista tal-enerġija, u l-kapaċitajiet tal-multimetru.