1. Introduzzjoni
The Zurn P6900-B-L AquaSense Electronics Module with Solenoid is a replacement component designed for Zurn AquaSense sensor faucets, specifically models Z6912, Z6913, Z6915, and Z6920. This module integrates the solenoid valve, battery pack, and the necessary wiring to connect to the faucet's infrared proximity sensor, enabling hands-free operation. This manual provides instructions for proper installation, operation, and maintenance of the module.
2. Informazzjoni dwar is-Sigurtà
- Always turn off the water supply to the faucet before beginning any installation or maintenance.
- Disconnect electrical power if applicable before servicing.
- Ilbes tagħmir protettiv personali xieraq, bħal nuċċalijiet tas-sigurtà u ingwanti.
- Kun żgur li l-konnessjonijiet kollha huma sikuri biex tevita t-tnixxijiet.
- Armi batteriji qodma b'mod responsabbli skont ir-regolamenti lokali.
3. Kontenut tal-Pakkett
Iċċekkja li l-komponenti kollha huma preżenti qabel tibda l-installazzjoni:
- Zurn P6900-B-L AquaSense Electronics Module with Solenoid
- Battery Pack (integrated)
- 4 Batteriji Alkalini AA (inklużi)
- Connecting Wire to Faucet Sensor
- Small Hex Key/Wrench (for securing connections, if applicable)
- O-ring (for sealing connections, if applicable)

4. Setup u Installazzjoni
Follow these steps to install the Zurn P6900-B-L Electronics Module:
- Itfi l-Provvista tal-Ilma: Locate the main water shut-off valve for the faucet and turn it off completely.
- Disconnect Old Module (if replacing): Carefully disconnect the existing electronics module from the faucet sensor and water lines. Be prepared for residual water.
- Prepare New Module: Ensure the new P6900-B-L module has the included 4 AA alkaline batteries properly installed in the battery compartment.
- Qabbad il-Linji tal-Ilma: Attach the solenoid valve portion of the new module to the appropriate hot and cold water supply lines. Use thread sealant tape or pipe dope as recommended by local plumbing codes. Ensure connections are hand-tight, then use a wrench for a final quarter-turn, avoiding overtightening.
- Connect Sensor Wire: Carefully connect the wire from the electronics module to the faucet's infrared proximity sensor. The connector pins are delicate; align them precisely to avoid bending. Removing any rubber o-ring on the connector might assist in feeling for a solid connection, as a coupler nut typically secures the pieces.
- Modulu Sikur: Mount or secure the electronics module in a suitable location, typically under the sink, ensuring it is protected from moisture and easily accessible for future maintenance.
- Irrestawra l-Provvista tal-Ilma: Slowly turn the main water supply back on and check for any leaks at all connection points.
- Operazzjoni tat-Test: Activate the faucet sensor to verify proper water flow and shut-off.

5. Istruzzjonijiet Operattivi
The Zurn AquaSense Electronics Module controls water flow in conjunction with the faucet's infrared proximity sensor. To operate the faucet:
- Attivazzjoni: Place your hands within the detection range of the faucet's sensor. The sensor will detect your presence.
- Fluss tal-Ilma: Upon detection, the electronics module will activate the solenoid valve, allowing water to flow from the faucet.
- Diżattivazzjoni: Remove your hands from the sensor's detection range. The module will then close the solenoid valve, stopping the water flow.
The system is designed for hands-free operation, promoting hygiene and water conservation.
6. Manutenzjoni
Regular maintenance ensures optimal performance and longevity of your Zurn AquaSense Electronics Module.
6.1. Sostituzzjoni tal-batterija
The module is powered by 4 AA alkaline batteries. When the batteries are low, the faucet may exhibit inconsistent operation or cease to function. To replace the batteries:
- Itfi l-Provvista tal-Ilma: Itfi l-provvista tal-ilma għall-faucet.
- Aċċess għall-Kompartiment tal-Batterija: Locate the battery compartment on the electronics module. This is typically secured with a cover.
- Neħħi Batteriji Qadim: Open the compartment and remove the old AA batteries.
- Daħħal Batteriji Ġodda: Daħħal erba' batteriji alkalini AA ġodda, waqt li tiżgura l-polarità korretta (+/-).
- Kompartiment Sikur: Agħlaq u waħħal sew l-għatu tal-kompartiment tal-batterija.
- Irrestawra l-Provvista tal-Ilma u Ittestja: Turn the water supply back on and test the faucet's operation.
6.2. Tindif
Periodically inspect the module and connections for any signs of corrosion or debris. Clean the exterior of the module with a soft, damp drapp. Tużax tindif jew solventi li joborxu.
7 Issolvi l-problemi
If your Zurn AquaSense faucet is not functioning correctly, refer to the following table for common issues and solutions:
| Problema | Kawża Possibbli | Soluzzjoni |
|---|---|---|
| No water flow when sensor is activated | Batteriji baxxi jew mejta Provvista tal-ilma mitfija Sensor wire disconnected or damaged Malfunzjoni tal-valv tas-solenojd | Ibdel il-batteriji Check water supply valve Verify sensor wire connection Contact Zurn support for solenoid replacement |
| Water flows continuously | Sensor ostakolat jew difettuż Valv tas-solenojd imwaħħal miftuħ | Clean sensor lens; check for obstructions Contact Zurn support for solenoid inspection/replacement |
| Fluss ta 'ilma dgħajjef | Pressjoni baxxa tal-ilma L-arjatur misdud Solenoid partially obstructed | Check building water pressure Clean or replace faucet aerator Contact Zurn support for solenoid inspection |
| Is-senser ma jirrispondix | Batteriji baxxi jew mejta Sensor lens dirty Sensor wire disconnected or damaged | Ibdel il-batteriji Lenti tas-sensorju nadifa Verify sensor wire connection |
8. Speċifikazzjonijiet
| Karatteristika | Dettall |
|---|---|
| Isem tal-Mudell | P6900-B-L |
| Numru tal-Parti | P6900-B-L |
| Piż tal-oġġett | 1.12 liri |
| Dimensjonijiet tal-Prodott | 6 x 4 x 3.2 pulzieri |
| Materjal | Plastik, Metall |
| Batteriji | 4 AA Alkaline (included) |
| Compatible Faucets | Z6912, Z6913, Z6915, Z6920 Series |
| Karatteristika Speċjali | Ħieles Ċomb |
| UPC | 670240576582 |
9. Garanzija u Appoġġ
The Zurn P6900-B-L AquaSense Electronics Module is covered by a limited manufacturer's warranty. For specific warranty terms and conditions, please refer to the documentation provided with your original Zurn product or visit the official Zurn websit.
For technical support, replacement parts, or further assistance, please contact Zurn Customer Service:
- Websit: www.zurn.com
- Informazzjoni ta' Kuntatt: Refer to the 'Contact Us' section on the Zurn websit għal numri tat-telefon u appoġġ bl-email.