Satel AXD-200

Satel BE WAVE AXD-200 Multipurpose Detector User Manual

Model: AXD-200

1. Introduzzjoni

The Satel BE WAVE AXD-200 is a wireless multipurpose detector designed for integration into home and apartment alarm systems. It functions as a window and door contact sensor, providing anti-burglary protection, and also includes a temperature sensor. This manual provides essential information for the proper installation, operation, and maintenance of your AXD-200 detector.

Satel BE WAVE AXD-200 Multipurpose Detector, showing the main unit and magnet component.

Figure 1: Satel BE WAVE AXD-200 Multipurpose Detector components.

2. Informazzjoni dwar is-Sigurtà

  • Aqra l-istruzzjonijiet kollha bir-reqqa qabel l-installazzjoni u l-użu.
  • This device is intended for outdoor use, but ensure it is protected from direct extreme weather conditions if possible.
  • Use only the specified battery type (1 CR123A Lithium-manganese dioxide). Incorrect battery types may cause damage or fire.
  • Tippruvax tiżżarma jew issewwi l-apparat int stess. Irreferi għal persunal tas-servizz kwalifikat.
  • Keep the device away from strong magnetic fields, which can interfere with its operation.

3. Setup

3.1 Tneħħija tal-kaxxa u l-komponenti

Ivverifika li l-komponenti kollha huma preżenti:

  • AXD-200 Detector Unit
  • Komponent tal-kalamita
  • Mounting Screws and Anchors (if included)

3.2 Installazzjoni tal-batterija

  1. Iftaħ id-ditekter casing bir-reqqa.
  2. Insert one CR123A Lithium-manganese dioxide battery, observing the correct polarity (+/-).
  3. Agħlaq id-ditekter casing b'mod sigur.

3.3 Immuntar tad-Ditekter

The AXD-200 detector consists of two parts: the main detector unit and a magnet. These parts must be mounted in close proximity to each other on a window or door frame and the moving part (window/door) respectively.

  1. Choose a suitable location on the window or door frame where the detector and magnet can be aligned when the window/door is closed. The gap between the two components should not exceed 1 cm (0.4 inches).
  2. Naddaf il-wiċċ tal-immuntar sewwa.
  3. Attach the main detector unit to the stationary part of the frame using the provided screws or adhesive strips.
  4. Attach the magnet component to the moving part of the window or door, ensuring it aligns with the marked area on the main detector unit when closed.
White Satel BE WAVE AXD-200 detector installed on a white door frame and door.

Figura 2: Eżample installation of the white AXD-200 detector.

Brown Satel BE WAVE AXD-200 detector installed on a wooden door frame and door.

Figura 3: Eżample installation of the brown AXD-200 detector.

3.4 Pairing with a Smart HUB

The AXD-200 detector requires a Satel Smart HUB or Smart HUB Plus for operation. Refer to your Smart HUB's manual for specific pairing instructions. Generally, this involves putting the HUB into pairing mode and then activating the detector (e.g., by opening/closing the contact or pressing a pairing button if available).

Satel Smart HUB device on a table next to a plant, indicating its necessity for the detector's operation.

Figure 4: A Satel Smart HUB is required for detector functionality.

3.5 Konfigurazzjoni tal-App

Once paired, use the dedicated Satel mobile application to configure the detector settings, view its status, and monitor temperature readings. The app allows you to customize notifications and integrate the detector into your overall security system.

Mobile application interface showing detector status, open/close events, and temperature readings.

Figure 5: Mobile application for configuration and monitoring.

4. It-tħaddim tad-Detector

4.1 Door/Window Contact Function

The detector monitors the open/close status of the door or window it is installed on. When the magnet separates from the main unit (door/window opens), the detector sends a signal to the Smart HUB, triggering an alarm or notification according to your system's configuration.

4.2 Temperature Sensor Function

The integrated temperature sensor continuously monitors the ambient temperature at the detector's location. This data is transmitted to the Smart HUB and can be viewed via the mobile application. You may be able to set temperature thresholds for alerts within the app.

4.3 Tamper Protezzjoni

The AXD-200 features tamper protection. If the detector casing is opened or forcibly removed from its mounting location, it will trigger a tamper alarm, enhancing the security of your system.

Illustration of tamper protection, showing an alarm icon and a hand attempting to pry open the detector.

Figura 6: Tamper protection mechanism.

5. Manutenzjoni

5.1 Sostituzzjoni tal-batterija

When the battery level is low, your Smart HUB and mobile application will typically provide a notification. Replace the CR123A battery as described in Section 3.2. Always use a fresh, high-quality battery of the specified type.

5.2 Tindif

Clean the exterior of the detector with a soft, dry cloth. Do not use abrasive cleaners, solvents, or excessive moisture, as these can damage the device.

5.3 Aġġornamenti tal-Firmware

Periodically check the Satel mobile application or website for available firmware updates for your detector. Updates can improve performance, add features, or address security vulnerabilities. Follow the instructions provided by Satel for any update procedures.

6 Issolvi l-problemi

  • Id-ditekter mhux qed jirrispondi: Check battery level. Ensure the detector is within range of the Smart HUB. Re-pair the detector if necessary.
  • Allarmi foloz: Verify the mounting alignment of the detector and magnet. Ensure the gap is not too wide. Check for any loose components or vibrations that might cause false triggers.
  • Temperature readings inaccurate: Ensure the detector is not exposed to direct sunlight or extreme heat/cold sources that do not reflect the ambient room temperature.
  • Kwistjonijiet ta' konnettività: Check the Smart HUB's status and Wi-Fi connection. Ensure there are no significant obstructions or interference sources between the detector and the HUB.

If issues persist, consult the Satel support websit jew ikkuntattja lis-servizz tal-konsumatur.

7. Speċifikazzjonijiet

KaratteristikaDettall
Numru tal-MudellAXD-200
BrandSatel
ManifatturSATEL sp. z oo
Dimensjonijiet (L x W x H)25.4 x 5.08 x 6.86 ċm (10 x 2 x 2.7 pulzieri)
Piż80 gramma (2.82 uqija)
Tip ta 'batterija1 x CR123A (Lithium-manganese dioxide)
Batterija InklużaNru
Użu RakkomandatFor alarm systems
Użu fuq ġewwa/barraBarra
Numru ta' Oġġetti fil-Pakkett1
Pajjiż ta' OriġiniIstati Uniti tal-Amerika

8. Garanzija u Appoġġ

For detailed warranty information, please refer to the official Satel webis-sit jew il-karta tal-garanzija inkluża mal-prodott tiegħek. Żomm l-irċevuta tax-xiri tiegħek bħala prova tax-xiri.

For technical support, product inquiries, or service, please visit the official Satel support portal or contact their customer service department. Contact information can typically be found on the manufacturer's websit.

Satel Official Websit: www.satel.pl

Dokumenti Relatati - AXD-200

Preview SATEL AXD-200 PL Multipurpose Detector User Manual
User manual for the SATEL AXD-200 PL Multipurpose Detector, detailing its features, installation, testing, and technical specifications. This detector offers shock, opening, flood, temperature, and roller shutter detection capabilities, designed for use with the BE WAVE system.
Preview Manwal tad-Ditekter Multifunzjonali mingħajr Fili SATEL AXD-200
Dan il-manwal jipprovdi informazzjoni dettaljata dwar id-ditekter bla fili multifunzjonali SATEL AXD-200, inklużi l-karatteristiċi tiegħu, l-ispeċifikazzjonijiet tekniċi, il-gwida tal-installazzjoni, u l-modi operattivi. Ikopri diversi tipi ta' ditekters bħal ditekters ta' kuntatt manjetiku, xokk, temperatura, u għargħar, kif ukoll espansuri taż-żoni bil-wajer, għall-użu mas-sistemi ABAX 2 u ABAX.
Preview Gwida għall-Installazzjoni Rapida tad-Detector Universali SATEL XD-2
A concise guide for the installation of the SATEL XD-2 universal detector, covering its functions as a magnetic contact, shock detector, and water flood detector. Includes wiring instructions and safety precautions.
Preview SATEL ABAX 2 Wireless Device Quick Installation Guide
Concise installation guide for SATEL ABAX 2 wireless devices, including models like ACD-220, ACMD-200, and AXD-200. Covers safety, battery handling, system integration, and signal testing for professional installers.
Preview Manwal tad-Detector tad-Duħħan u s-Sħana Wireless Satel ASD-200
Manwal komprensiv għad-ditekter tad-duħħan u s-sħana mingħajr fili Satel ASD-200, li jkopri l-karatteristiċi, l-installazzjoni, il-manutenzjoni, is-sostituzzjoni tal-batterija, u l-ispeċifikazzjonijiet. Tgħallem kif tuża u żżomm l-apparat tad-detezzjoni tan-nar tiegħek b'mod effettiv.
Preview Manwal tal-Utent tad-Ditekter tad-Duħħan u s-Sħana mingħajr Fili SATEL ASD-200 SK
Manwal komprensiv għall-utent għad-ditekter tad-duħħan u s-sħana mingħajr fili SATEL ASD-200 SK. Tgħallem dwar il-karatteristiċi, l-installazzjoni, it-tħaddim, il-manutenzjoni, u l-ispeċifikazzjonijiet tekniċi għal skoperta affidabbli tan-nar.