AUTOOL SVB305

AUTOOL SVB305 Two-Way Articulating Endoscope Camera User Manual

Mudell: SVB305

1. Introduzzjoni

This manual provides detailed instructions for the proper use and maintenance of the AUTOOL SVB305 Two-Way Articulating Endoscope Camera. Please read this manual thoroughly before operating the device to ensure safe and efficient use. The AUTOOL SVB305 is designed for inspecting hard-to-reach areas, featuring a 210° articulating probe, a 4.3-inch IPS display, and a 1080P camera for clear visual inspection.

2. Prodott Aktarview

2.1 Kontenut tal-Pakkett

The AUTOOL SVB305 package typically includes the following items:

  • AUTOOL SVB305 Endoscope Camera Unit
  • Flexible Articulating Probe (3FT)
  • Karta Micro SD ta' 32GB (installata minn qabel jew inkluża separatament)
  • Cable tal-Iċċarġjar tal-USB-C
  • Manwal għall-Utent
  • Kawża tal-Ħażna
AUTOOL SVB305 Endoscope Camera package contents

Image: Contents of the AUTOOL SVB305 Endoscope Camera package, including the main unit, flexible probe, USB-C cable, user manual, and storage case.

2.2 Karatteristiċi ewlenin

  • Two-Way 210° Articulating Probe: Allows flexible bending of the probe tip for comprehensive viewing in confined spaces.
  • 0.21-inch (6.35mm) Diameter Probe: Designed for accessing narrow openings.
  • Kamera HD 1080P: Captures clear images and videos with 1.0MP CMOS sensor.
  • Skrin IPS ta' 4.3 pulzieri: Provides a sharp and vibrant display for real-time viewing.
  • Sonda li ma jgħaddix ilma minnha IP67: Suitable for use in wet and oily environments.
  • Dwal LED aġġustabbli: Six high-intensity LEDs with three brightness levels for optimal illumination.
  • 2000mAh Batterija Rikarikabbli: Joffri sa 3 sigħat ta' tħaddim kontinwu.
  • 32GB Mikro SD Card: For convenient storage of captured media.
  • Automatic Temperature Alarm: Alerts and shuts down the device if the probe temperature exceeds 176°F (80°C).
AUTOOL SVB305 Endoscope Camera main unit and probe

Image: The AUTOOL SVB305 Endoscope Camera, showing the main display unit, control buttons, and the flexible articulating probe.

Diagram of 2-Way 210 degree articulation and lens specifications

Image: Detailed diagram illustrating the 2-way 210° articulation capability of the probe, 70° viewing angle, 1.3-inch bending radius, 0.2-inch lens diameter, and 0.9-4.0 inch depth of field.

Diagram of 4.3-inch IPS screen layers and resolution

Immaġni: Splodiet view of the 4.3-inch IPS screen, highlighting its tempered glass, IPS LCD, and backlight components, with an image resolution of 1280x720.

3. Setup

3.1 Iċċarġjar tal-Apparat

Before first use, fully charge the endoscope camera. Connect the provided USB-C charging cable to the device's charging port and a suitable USB power adapter (not included). The charging indicator will show the charging status. A full charge provides approximately 3 hours of working time.

Diagram showing 2000mAh battery and 3 hours working time

Image: Illustration of the 2000mAh rechargeable battery providing 3 hours of working time, with the device connected to a charger via USB-C cable.

USB-C charging cable connected to the device

Image: The endoscope camera being charged using the USB-C charging cable, highlighting the charging port.

3.2 Daħħal il-Mikro SD Card

Locate the Micro SD card slot on the device. Insert the provided 32GB Micro SD card into the slot until it clicks into place. This card is essential for saving photos and videos.

Diagram showing 32GB memory card insertion

Image: Illustration showing the insertion of the 32GB Micro SD card into the designated slot on the endoscope camera.

4. Istruzzjonijiet Operattivi

4.1 Tixgħel/Jitfi

Press and hold the power button to turn the device on or off. The 4.3-inch IPS screen will illuminate upon startup.

4.2 Kontrolli Bażiċi

The device features several buttons and a rotation wheel for control:

  • Power On/Light Control: Turns the device on/off and adjusts LED brightness.
  • Buttuna tar-Ritratti/Vidjo: Captures still images or starts/stops video recording.
  • Ċavetta tas-Settings: Accesses the device settings menu.
  • Up/Down/Toggle Keys: Navigates menus and adjusts settings.
  • Ċavetta OK: Jikkonferma l-għażla.
  • Rotation Wheel: Controls the articulation of the probe tip.
Labeled diagram of endoscope camera components and controls

Image: A detailed diagram labeling the 5-inch display, SD interface, M key, Up key, Rotation Wheel, HD Camera, Flexible Cable, OK Key, Charging Port, Down/Toggle Key, Settings Key, Power on Light-control, and Photo/Video button.

4.3 Steering the Probe

Use the rotation wheel on the handle to articulate the probe tip up to 210° in two directions. This allows for flexible navigation and viewing around corners or obstacles within confined spaces.

Endoscope probe articulating inside a pipe

Image: The flexible articulating probe navigating inside a curved pipe, demonstrating its two-way 210° steering capability.

User operating the rotation wheel to steer the probe

Image: A hand operating the scroll roller (rotation wheel) to switch the viewing angle of the flexible gooseneck probe, illustrating its ability to reach narrow spaces.

4.4 Aġġustament tad-Dwal LED

The probe tip is equipped with 6 high-intensity LED lights. Press the dedicated light control button to cycle through three adjustable brightness levels, ensuring clear visibility in dark environments.

Endoscope probe with adjustable LED lights

Image: The endoscope probe tip showing its 6 LED lights and illustrating the three levels of brightness adjustment.

Diagram showing 3 adjustable brightness levels for LEDs

Image: Visual representation of the 6 LEDs and their 3 adjustable brightness levels, designed for optimal visibility in dark areas.

4.5 Qbid ta' Ritratti u Vidjows

Press the Photo/Video button to take a still image. Press and hold the same button to start video recording; press again to stop. All captured media is saved to the installed 32GB Micro SD card.

User holding the endoscope camera during inspection

Image: A user wearing gloves holding the AUTOOL SVB305 endoscope camera, with the probe inserted into an engine compartment, demonstrating its use in an inspection scenario.

4.6 Appoġġ Multilingwi

The device supports multiple languages. Access the settings menu to select your preferred language, including English, French, Spanish, Russian, German, Italian, Chinese, and Japanese.

Multilingual options on the endoscope camera

Image: A display showing various language options available on the AUTOOL SVB305, including English, French, Spanish, Russian, German, Italian, Chinese, and Japanese.

5. Manutenzjoni

5.1 Tindif tas-Sonda

The probe is IP67 waterproof and oilproof. After use, especially in dirty or oily environments, gently wipe the probe with a soft, damp cloth. For stubborn grime, a mild, non-abrasive cleaner can be used. Ensure the probe is dry before storage.

Endoscope probe submerged in water, indicating IP67 waterproof rating

Image: The endoscope probe tip submerged in water, visually representing its IP67 waterproof capability.

Diagram showing IP67 waterproof and corrosion-resistant material

Image: Illustration emphasizing the IP67 waterproof and corrosion-resistant materials used in the probe's construction, suitable for various environments.

5.2 Kura tal-Batterija

To prolong battery life, avoid fully discharging the battery frequently. Charge the device regularly, even if not in use for extended periods. Store the device in a cool, dry place.

5.3 Ħażna

When not in use, store the endoscope camera and its accessories in the provided storage case to protect them from dust, moisture, and physical damage.

6 Issolvi l-problemi

6.1 L-ebda Immaġni fuq l-Iskrin

  • Kun żgur li l-apparat ikun mixgħul u kompletament iċċarġjat.
  • Check if the probe cable is securely connected to the main unit.
  • Ivverifika li l-lenti tal-kamera hija nadifa u ħielsa minn ostruzzjonijiet.

6.2 Device Shuts Down Unexpectedly

The AUTOOL SVB305 features an automatic alarm and shutdown mechanism if the probe temperature exceeds 176°F (80°C) to prevent damage. Allow the device to cool down before resuming operation. If the issue persists and is not related to temperature, ensure the battery is adequately charged.

Automatic alarm and shutdown for high temperature

Image: Visual representation of the automatic alarm and shutdown feature that activates when the probe temperature exceeds 176°F (80°C), indicating high temperature protection.

6.3 Unable to Save Photos/Videos

  • Ensure a 32GB Micro SD card is correctly inserted.
  • Iċċekkja jekk il-kard tal-Micro SD għandhiex biżżejjed spazju liberu.
  • Verify that the Micro SD card is not locked (read-only).

7. Speċifikazzjonijiet

KaratteristikaSpeċifikazzjoni
Numru tal-MudellSVB305
Dijametru tas-Sonda0.21 pulzier (6.35mm)
Angolu tal-Artikolazzjoni210° b'żewġ direzzjonijiet
Display Screen4.3-il pulzier IPS
Riżoluzzjoni tal-Qbid tal-Vidjo1080p (1280x720)
Senser tal-Kamera1.0MP HD CMOS
Dwal LED6 livelli ta 'luminożità aġġustabbli
Klassifikazzjoni li ma jgħaddix ilma minnhaIP67 (sonda)
BatterijaPolimer tal-Litju 2000mAh
Ħin tax-XogħolAppross. 3 sigħat
Midja tal-ĦażnaKarta Mikro SD (32GB inkluża)
Temperatura operattivaUp to 176°F (80°C) for probe
Dimensjonijiet tal-Pakkett16.57 x 8.5 x 3.46 pulzieri
Piż tal-oġġett2.67 Liri

8. Garanzija u Appoġġ

The AUTOOL SVB305 Endoscope Camera comes with a Tliet Snin Garanzija against manufacturing defects. For any quality issues or technical assistance, please contact AUTOOL customer support. They are committed to providing solutions and technical support until satisfaction. Please refer to the official AUTOOL webis-sit jew id-dokumentazzjoni tax-xiri tiegħek għal dettalji ta' kuntatt speċifiċi.

Contact information for support can typically be found on the manufacturer's webis-sit jew fl-imballaġġ tal-prodott.

Dokumenti Relatati - SVB305

Preview Manwal tal-Utent tal-Boreskopju tal-Vidjo Artikolat AUTOOL SVB305
This user manual provides comprehensive instructions for the AUTOOL SVB305 Articulating Video Borescope. It covers safety precautions, product introduction, structure, operation, troubleshooting, maintenance, warranty, and return policies for automotive inspections.
Preview AUTOOL SVB303 Four-way Articulating Borescope User Manual
User manual for the AUTOOL SVB303 Four-way Articulating Borescope, detailing its features, operation, safety guidelines, maintenance, warranty, and return policies. Includes technical specifications and troubleshooting tips.
Preview AUTOOL SDT202 Manwal għall-Utent tad-Ditekter tat-Tnixxija tad-duħħan
Manwal tal-utent għall-AUTOOL SDT202 Duħħan Leak Detector. Jipprovdi struzzjonijiet dettaljati għall-operat, il-manutenzjoni, u s-soluzzjoni tal-problemi ta' din l-għodda dijanjostika tal-karozzi, iddisinjata għal skoperta effiċjenti ta' tnixxijiet fil-vetturi.
Preview Manwal tal-Utent tat-Tindif tar-Ramel tal-Ġewż tal-Karozzi AUTOOL HTS558 | AUTOOL Tech
Manwal tal-utent għall-AUTOOL HTS558, li jneħħi l-karbonju bir-ramel tal-ġewż tal-karozzi, li jiddeskrivi l-karatteristiċi, it-tħaddim, il-manutenzjoni u l-linji gwida tas-sigurtà tiegħu għat-tindif effettiv tas-sistema tad-dħul tal-magna.
Preview Manwal tal-Utent tal-Kit tal-Manifold Diġitali Intelliġenti AUTOOL LM70
User manual for the AUTOOL LM70 Smart Digital Manifold Kit, providing detailed instructions on operation, safety, maintenance, and technical specifications for automotive air conditioning system diagnostics.
Preview Manwal tal-Utent tal-Gauge tal-Pressjoni taż-Żejt tat-Trażmissjoni AUTOOL PT650
Manwal komprensiv għall-utent għall-Gauge tal-Pressjoni taż-Żejt tat-Trażmissjoni AUTOOL PT650, li jkopri informazzjoni dwar l-operat, is-sigurtà, il-manutenzjoni u l-garanzija. Gwida essenzjali għall-professjonisti u d-dilettanti tal-karozzi.