1. Introduzzjoni
This manual provides essential information for the safe and effective operation of your UEi Test Instruments DL569 400A Dual Display Clamp Meter. Please read this manual thoroughly before using the device and retain it for future reference. The DL569 is designed for professional use in electrical testing, offering a dual display for convenient readings of various electrical parameters.

Figure 1: The UEi Test Instruments DL569 400A Dual Display Clamp Metru. Din l-immaġni turi l-parti ta' quddiem view of the yellow clamp meter with its dual digital display, rotary dial, and measurement input jacks.
2. Informazzjoni dwar is-Sigurtà
The DL569 clamp meter is safety rated CATIV 300V / CATIII 600V and certified by ETL to IEC 61010-1, 3rd edition. Adherence to safety guidelines is crucial to prevent electrical shock, injury, or damage to the meter. Always follow these precautions:
- Always inspect the meter, test leads, and accessories for any damage before use. Do not use if damaged.
- Ensure the function switch is set to the correct measurement range before connecting to a circuit.
- Teċċedix il-limiti massimi tad-dħul għal kwalunkwe funzjoni.
- Oqgħod attent meta taħdem bil-voltages 'il fuq minn 30V AC RMS, 42V peak, jew 60V DC, għax dawn joħolqu periklu ta' xokk elettriku.
- Always wear appropriate personal protective equipment (PPE), such as safety glasses and insulated gloves.
- Do not operate the meter in wet environments or in the presence of explosive gases or dust.
- Ibdel il-batteriji minnufih meta jidher l-indikatur ta' batterija baxxa biex tiżgura qari preċiż.
3. X'hemm fil-Kaxxa
Malli tiftaħ il-pakkett, ivverifika li l-oġġetti kollha elenkati hawn taħt huma preżenti u mhux imħassra:
- DL569 Doppju Display Clamp Miter
- Test Leads (ATL55)
- Klipps tal-Alligator
- AAA Batteries (Quantity: 2)
- Pouch/Case
- Manwal ta 'Istruzzjoni (dan id-dokument)

Figure 2: The DL569 Clamp Meter shown with its standard accessories, including test leads, alligator clips, batteries, and a protective carrying pouch.
4. Karatteristiċi tal-prodott
The DL569 clamp meter offers a range of features designed for efficiency and accuracy:
- Dual Display Screen: Provides simultaneous readings, with Amps (AC/DC) always displayed on the upper screen for easy monitoring.
- NCV Detection Function: Vol mingħajr kuntatttage detection allows for checking electrical status by measuring electromagnetic field intensity without direct contact with wires.
- Funzjonijiet ta' Kejl Komprensivi: Measures AC Volts (750VAC), DC Volts (1000VDC), AC Current (400A AC), AC Micro Volts (400mV), Resistance (10MOhms). Includes Continuity and Diode test functions.
- Integrated Test Lead Storage: Conveniently store test leads directly on the meter for easy access and organization.

Figura 3: Close-up view of the DL569's dual digital display, showing simultaneous readings for different parameters, enhancing user convenience.

Figure 4: Detail of the integrated test lead storage on the back of the DL569 meter, designed for secure and convenient organization of test leads.
5. Setup
5.1 Installazzjoni tal-batterija
- Sib il-kompartiment tal-batterija fuq wara tal-miter.
- Uża tornavit biex tiftaħ il-qoxra tal-batterija.
- Daħħal żewġ batteriji AAA, waqt li tiżgura l-polarità korretta (+/-).
- Ibdel l-għatu tal-batterija u waħħalha bil-kamin.
5.2 Spezzjoni Inizjali
Before each use, perform a visual inspection of the meter, test leads, and accessories for any signs of damage, cracks, or exposed wiring. Ensure the test leads are securely connected to the meter's input jacks.
6. Istruzzjonijiet Operattivi
6.1 Power On/Off
Rotate the function dial from the 'OFF' position to any desired measurement function to power on the meter. To power off, rotate the dial back to the 'OFF' position.
6.2 AC Current (Amps) Measurement
- Rotate the function dial to the 'A~' position.
- Iftaħ il-clamp xedaq billi tagħfas il-grillu.
- Dawwar konduttur wieħed bis-clamp xedaq. Kun żgur li x-xedaq ikun magħluq għalkollox.
- Read the AC current value on the upper display.
6.3 TitjiratagKejl elettroniku (AC/DC)
- Connect the red test lead to the 'VΩ' input jack and the black test lead to the 'COM' input jack.
- Rotate the function dial to 'V~' for AC voltage jew 'V=' għal volum DCtage.
- Qabbad il-probi tat-test b'mod parallel maċ-ċirkwit jew il-komponent li qed jiġi ttestjat.
- Aqra l-voltagIl-valur fuq il-wiri.
6.4 Resistance (Ohms) Measurement
- Connect the red test lead to the 'VΩ' input jack and the black test lead to the 'COM' input jack.
- Rotate the function dial to the 'Ω' position.
- Kun żgur li ċ-ċirkwit jew il-komponent li qed jiġi ttestjat ma jkunx enerġizzat.
- Qabbad il-probi tat-test mal-komponent.
- Aqra l-valur tar-reżistenza fuq il-wiri.
6.5 Vol. Mingħajr Kuntatttage (NCV) Sejbien
- Rotate the function dial to the 'NCV' position.
- Move the top of the meter near the conductor or outlet to be tested.
- Il-miter jindika l-preżenza tal-volum tal-ACtage through an audible beep and/or visual indicator.
7. Manutenzjoni
7.1 Tindif
Imsaħ il-marka tal-miterasing b'reklamaramp cloth and a mild detergent. Do not use abrasives or solvents. Ensure the meter is completely dry before storage or further use.
7.2 Sostituzzjoni tal-batterija
When the low battery indicator appears on the display, replace the batteries as described in Section 5.1. Remove batteries if the meter will not be used for an extended period to prevent leakage.
7.3 Ħażna
Store the meter in its protective pouch in a cool, dry environment, away from direct sunlight and extreme temperatures.
8 Issolvi l-problemi
| Problema | Kawża Possibbli | Soluzzjoni |
|---|---|---|
| Il-miter ma jixgħelx. | Batteriji mejta jew installati ħażin. | Iċċekkja l-polarità tal-batterija jew ibdel il-batteriji. |
| No reading or 'OL' displayed. | Funzjoni magħżula ħażina, ċirkwit miftuħ, jew firxa tal-kejl maqbuża. | Select correct function, check circuit continuity, or ensure measurement is within range. |
| Qari mhux preċiż. | Low battery, damaged test leads, or external interference. | Replace batteries, inspect/replace test leads, move away from strong electromagnetic fields. |
| Il-funzjoni NCV ma tiskoprix il-volumtage. | Voltage too low, shielded wires, or meter not close enough. | Tiżgura voltage is present, try closer proximity, or use direct contact measurement. |
9. Speċifikazzjonijiet
| Parametru | Valur |
|---|---|
| Numru tal-Mudell | DL569 |
| AC Amps Medda | 40.00A (±2.9% + 15dgts), 400.0A (±1.9% + 8dgts) |
| DC Volts Range | 400.0mV (±0.5% + 5dgts), 400.0V (±0.5% + 5dgts), 1000V (±0.8% + 10dgts) |
| AC Volts Range | 400.0V & 750V (±2.0% + 5dgts) |
| Resistance (Ohms) Range | 4.000kΩ & 40.00kΩ (±1.0% + 4dgts) |
| Kontinwità | Iva |
| Test tad-Diode | Iva |
| Klassifikazzjoni tas-Sigurtà | CATIV 300V / CATIII 600V |
| Ċertifikazzjoni | ETL to IEC 61010-1, 3rd edition |
| Sors tal-Enerġija | 2 batteriji AAA |
| Dimensjonijiet tal-Prodott | 1 x 1 x 1 pulzier; 1.12 Liri |
| Manifattur | Strumenti tat-Test UEi |
10. Garanzija u Appoġġ
For warranty information, technical support, or service inquiries regarding your UEi Test Instruments DL569 Clamp Meter, please contact UEi Test Instruments directly through their official webis-sit jew il-kanali tas-servizz tal-konsumatur. Żomm il-prova tax-xiri tiegħek għal talbiet ta' garanzija.