Tecmojo 4U Server Rack (Model 11130306) Instruction Manual

This manual provides detailed instructions for the installation, operation, and maintenance of your Tecmojo 4U Server Rack.

1. Introduzzjoni

The Tecmojo 4U Server Rack (Model 11130306) is a versatile and durable solution for organizing 19-inch IT equipment. Designed for both vertical and horizontal wall mounting, it features a vented enclosure to ensure optimal airflow and protect your valuable devices. This manual provides essential information for safe installation, proper use, and maintenance.

Karatteristiċi ewlenin:

  • Kostruzzjoni Durabbli: Made from heavy-duty cold rolled steel with an electrostatic powder coat to prevent rust and corrosion.
  • Kapaċità Għolja: Supports up to 60 lbs (27 kg) of equipment.
  • Disinn li jiffranka l-ispazju: Offers flexible vertical or horizontal installation options.
  • Fluss tal-Arja Ottimizzat: Features four-sided vents to enhance air circulation and prolong equipment life.
  • Disinn Konsiderat: Adjustable rack rails and bottom knock-out holes for efficient cable management.
  • Konformità Standard: EIA/ECA-310-E compliant for 19-inch rack-mountable equipment.
Tecmojo 4U Server Rack, front-left view, showing vented enclosure and side panels.
Figure 1: Tecmojo 4U Server Rack, showcasing its vented design and robust construction.

2. Informazzjoni dwar is-Sigurtà

Please read and understand all safety instructions before installing or operating the Tecmojo 4U Server Rack. Failure to do so may result in injury or damage to equipment.

  • Kapaċità tal-piż: Do not exceed the maximum weight capacity of 60 lbs (27 kg). Overloading can cause the rack to fail, leading to equipment damage or personal injury.
  • Wiċċ tal-Immuntar: Ensure the wall or mounting surface is structurally sound and capable of safely supporting the combined weight of the rack and all installed equipment.
  • Għodod: Use appropriate tools for installation. Wear safety glasses and gloves as needed.
  • Sigurtà Elettrika: When installing electrical equipment, ensure all power is disconnected and follow all relevant electrical safety codes and guidelines.
  • Ventilazzjoni: Do not obstruct the ventilation holes. Proper airflow is crucial for preventing equipment overheating.

3. Kontenut tal-Pakkett

Ivverifika li l-komponenti kollha huma preżenti fil-pakkett qabel tibda l-installazzjoni:

  • Tecmojo 4U Server Rack
  • Manwal ta' Istruzzjoni
  • M6*12 Screws (x16)
  • M6 Plastic Gaskets (x16)
  • Ġewż M6 (x16)
Contents included with the Tecmojo 4U Server Rack: instruction manual, M6 screws, M6 plastic gaskets, and M6 nuts.
Figure 2: Included hardware for mounting equipment within the rack.

4. Speċifikazzjonijiet

KaratteristikaSpeċifikazzjoni
Numru tal-Mudell11130306
Unitajiet Rack4U
Dimensjonijiet tal-Prodott (P x W x H)8.1" x 19.8" x 23.9" (205.5mm x 504mm x 606mm)
Piż tal-oġġett23.6 liri (10.7 kg)
Kapaċità tal-piż60 lbs (27 kg)
MaterjalCold Rolled Steel (Alloy Steel)
KulurIswed
KonformitàEIA/ECA-310-E
Diagram showing dimensions of the Tecmojo 4U Server Rack: Height 22.3\
Figure 3: Detailed dimensions and key specifications of the 4U Server Rack.

5. Installazzjoni u Setup

Follow these steps to properly install your Tecmojo 4U Server Rack:

  1. Agħżel Post: Select a suitable location on a sturdy wall. Ensure there is adequate space around the rack for ventilation, equipment access, and cable routing. The rack can be mounted either vertically or horizontally.
  2. Identify Studs: The rack's mounting holes are spaced 16 inches apart, designed to align with standard wall stud placement. Use a stud finder to locate and mark the center of the wall studs.
  3. Secure Rack to Wall: Using appropriate wall mounting hardware (not included), securely fasten the rack to the wall studs. Ensure all fasteners are tightened to prevent any movement or instability.
  4. Adjust Rack Rails: The internal rack rails can be adjusted to different depths. Use the various screw hole combinations to position the rails in 1.5-inch increments to best fit your equipment.
Wara view of the Tecmojo 4U Server Rack showing mounting holes spaced 16 inches apart to accommodate standard wall stud placement.
Figure 4: Rear mounting holes spaced 16 inches apart for wall stud installation.
Image of the Tecmojo 4U Server Rack showing adjustable mounting rails with 1.5-inch increments and bottom knock-out holes for cable pass-through.
Figure 5: Adjustable mounting rails and cable knock-out holes for flexible setup.

6. Operazzjoni

Once the rack is securely mounted, you can begin installing your equipment:

  • Installazzjoni ta' Tagħmir: Mount your 19-inch rack-mountable equipment into the rack using the provided M6 screws, plastic gaskets, and nuts. Ensure equipment is evenly distributed to maintain balance and stability.
  • Ġestjoni tal-Kejbil: Utilize the bottom knock-out holes for efficient routing and organization of cables. This helps maintain a tidy setup and prevents cable strain.
  • Fluss tal-arja: Ensure that the four-sided vents on the rack are not obstructed by walls, other equipment, or debris. Proper airflow is critical for maintaining optimal operating temperatures for your IT equipment.
Close-up view of the Tecmojo 4U Server Rack highlighting square rack holes for equipment mounting and side ventilation holes for airflow.
Figure 6: Square rack holes for secure equipment mounting and side ventilation for cooling.

7. Manutenzjoni

Regular maintenance helps ensure the longevity and optimal performance of your server rack:

  • Spezzjoni: Periodically inspect the rack for any signs of wear, damage, or loose fasteners. Tighten any loose screws or bolts.
  • Tindif: Keep the rack and its ventilation panels free from dust and debris. Use a soft, dry cloth for cleaning. Avoid using harsh chemicals or abrasive cleaners, which can damage the electrostatic powder coat finish.
  • Iċċekkja tal-ventilazzjoni: Ensure that all four-sided vents remain unobstructed to allow for continuous and efficient airflow.

8 Issolvi l-problemi

Hawn huma xi kwistjonijiet komuni u s-soluzzjonijiet potenzjali tagħhom:

  • Tisħin żejjed tat-tagħmir: If equipment within the rack is running hotter than expected, verify that all rack vents are clear and unobstructed. Ensure the rack is not placed in an area with poor ambient airflow. Consider the heat dissipation patterns of your specific equipment; some servers may require additional cooling solutions or different rack configurations.
  • Unstable Rack: If the rack feels unstable after installation, immediately remove all equipment. Re-check all wall mounting fasteners to ensure they are securely anchored into structural elements of the wall. Verify that the total weight of the equipment does not exceed the 60 lbs (27 kg) capacity.
  • Diffikultà fl-Immuntar tat-Tagħmir: Ensure you are using the correct M6 screws and nuts provided. Check that the rack rails are properly aligned and adjusted to the appropriate depth for your equipment.

9. Garanzija u Appoġġ

For warranty information regarding your Tecmojo 4U Server Rack, please refer to the purchase documentation or contact Tecmojo customer support directly.

For technical assistance, product inquiries, or to explore other Tecmojo products, please visit the official Tecmojo store:

Żur il-Ħanut Tecmojo

No official product videos were found that met the criteria for inclusion in this manual.

Dokumenti Relatati - 11130306

Preview Manwal tal-Istruzzjonijiet tar-Rack Vertikali li Jiġi Mmuntat mal-Ħajt TecMOJO
Manwal tal-istruzzjonijiet għar-Rack Vertikali tal-Ħajt TecMOJO, inklużi twissijiet ta' sigurtà, speċifikazzjonijiet, aċċessorji, u gwida tal-installazzjoni pass pass għall-mudelli 11130303 u 11130306.
Preview Manwal tal-Istruzzjonijiet tar-Rack tal-Ħajt Immuntat fuq il-Ħajt ta' Tecmojo Swing Gate
Manwal ta' struzzjonijiet komprensiv għat-Tecmojo Swing Gate Wall-Mount Rack, li jagħti dettalji dwar l-ispeċifikazzjonijiet, il-ħardwer, l-aċċessorji, u l-installazzjoni pass pass għal immuntar sigur tat-tagħmir.
Preview Tecmojo Open Frame Rack għal Servers u Tagħmir AV - Manwal ta' Istruzzjoni
Manwal ta' struzzjonijiet komprensiv għall-Open Frame Racks ta' Tecmojo għal Servers u Tagħmir AV. Jinkludi speċifikazzjonijiet, linji gwida dwar is-sigurtà, u struzzjonijiet dwar l-assemblaġġ għall-mudelli 11120121, 11120122, u 11120123.
Preview Manwal tal-Istruzzjonijiet tar-Rack tal-Ħajt Immuntat Vertikali ta' Tecmojo
Manwal tal-istruzzjonijiet għal Tecmojo Vertical Mount Wall Racks, inklużi speċifikazzjonijiet, twissijiet ta' sigurtà, u gwida għall-installazzjoni għall-mudelli 11130321, 11130322, 11130323, u 11130324.
Preview Manwal tal-Istruzzjonijiet tar-Rack tas-Server b'Toqob Kwadri b'2 Postijiet tal-Azzar Tecmojo
Manwal ta' struzzjoni għar-rack tas-server tal-azzar b'toqob kwadri b'2 arbli ta' Tecmojo, li jagħti dettalji dwar l-ispeċifikazzjonijiet, il-partijiet, u l-passi tal-assemblaġġ għal diversi kapaċitajiet U.
Preview Manwal tal-Istruzzjonijiet tar-Rack AV Immuntat mal-Ħajt ta' Tecmojo
Manwal ta' struzzjonijiet dettaljat għal Tecmojo Wall Mount AV Racks, li jkopri s-sigurtà, l-ispeċifikazzjonijiet, u l-assemblaġġ pass pass għall-mudelli 11120101, 11120102, u 11120103. Jinkludi listi ta' ħardwer u partijiet.