Introduzzjoni
This manual provides essential information for the proper installation, operation, and maintenance of your Mirage SETCLF120T Mini Split Air Conditioner Life 12 Plus. Please read this manual thoroughly before using the unit to ensure safe and efficient operation.
The LIFE12+ series offers superior efficiency among conventional (Non-Inverter) units, providing premium features for optimal comfort. It includes an option for Wi-Fi integration for remote control and monitoring, and a state-of-the-art remote control with an illuminated display for easy temperature management.
Prodott Overview
The Mirage SETCLF120T is a 1-ton, 115V mini split air conditioner designed for single cooling operation. It features advanced technologies for enhanced durability and user convenience.

Figura 1: Quddiem view of the Mirage SETCLF120T indoor unit, showcasing its sleek white design and "LIFE 12+" branding.

Figura 2: Angolat view of the Mirage SETCLF120T indoor unit, highlighting its compact and modern profile.

Figura 3: The state-of-the-art remote control for the Mirage SETCLF120T, featuring an illuminated display and clearly labeled buttons for various functions.
Setup u Installazzjoni
Proper installation is crucial for the performance and longevity of your air conditioner. It is highly recommended that installation be performed by a certified technician.
Lista ta' Kontroll ta' Qabel l-Installazzjoni:
- Ensure the installation location has adequate space and structural support for both indoor and outdoor units.
- Verify the electrical supply matches the unit's requirements (115V).
- Ikkonferma d-drenaġġ xieraq għall-ilma kondensat.
- Unpack all components and check for any shipping damage.
Key Installation Steps (Summary for User):
- Mount the indoor unit securely on the wall, ensuring it is level.
- Install the outdoor unit on a stable, level surface, away from obstructions.
- Connect the refrigerant lines and electrical wiring between the indoor and outdoor units.
- Perform vacuuming of the refrigerant lines to remove air and moisture.
- Check for refrigerant leaks using appropriate detection methods.
- Connect the condensate drain pipe to ensure proper water removal.
- Agħmel test biex tivverifika li l-funzjonijiet kollha qed jaħdmu sew.
Note: Detailed installation instructions are provided in the separate installer's manual. This section is for user awareness only.
Istruzzjonijiet Operattivi
Your Mirage SETCLF120T air conditioner is designed for user-friendly operation. All primary functions are controlled via the included remote control.
Funzjonijiet tal-Kontroll mill-bogħod:
- ON/OFF: Jixgħel jew jitfi l-unità.
- MODALITÀ: Selects the operating mode (e.g., Cool, Fan, Dry). Note: This model primarily supports cooling.
- TEMP +/-: Jaġġusta l-issettjar tat-temperatura mixtieqa.
- VELOĊITÀ TAL-FAN: Changes the fan speed (Auto, Low, Medium, High).
- SWING: Activates or deactivates the automatic louver swing for even air distribution.
- TIMER ON/OFF: Jissettja tajmer biex l-unità tinxtegħel jew tintefa awtomatikament.
- Rqad: Jaġġusta t-temperatura u l-veloċità tal-fann għal irqad komdu.
- TURBO: Activates maximum cooling power for rapid temperature reduction.
- DISPLAY: Jixgħel u jixgħel id-dawl tal-wiri tal-unità ta' ġewwa.
- MEMORJA: Ifakkar is-settings preferuti.
- DIRETTA: Adjusts the louver direction manually.
Karatteristiċi Speċjali:
- Remote Control Temperature Sensor: The remote control has a built-in temperature sensor to ensure uniform temperature distribution in your room.
- Anti-freeze Protection: Prevents damage by automatically preventing freezing or water spillage.
- Ditekter tat-Tnixxijiet: Protects the unit by detecting refrigerant gas loss.
- Għażla Wi-Fi: With an optional Wi-Fi harness and interface, you can control and monitor your unit from your smartphone.
Manutenzjoni
Regular maintenance ensures optimal performance and extends the lifespan of your Mirage air conditioner.
Tindif tal-filtru:
The air filters should be cleaned every two weeks or more frequently depending on usage and air quality.
- Itfi l-unità u skonnettja l-enerġija.
- Iftaħ il-pannell ta 'quddiem tal-unità ta' ġewwa.
- Neħħi l-filtri tal-arja.
- Naddaf il-filtri b'vacuum cleaner jew aħsilhom b'ilma fietel u deterġent ħafif.
- Laħlaħhom sewwa u ħallihom jinxfu kompletament f'żona fid-dell qabel ma terġa' tinstallahom.
- Agħlaq il-pannell ta 'quddiem.
Tindif tal-Kojl:
The indoor and outdoor coils should be inspected and cleaned annually by a qualified technician to remove dust and debris that can impede heat exchange.
Tindif Ġenerali:
- Imsaħ il-barra tal-unitajiet ta’ ġewwa u ta’ barra b’ċarruta ratba u damp drapp.
- Tużax kimiċi ħarxa, sustanzi li joborxu, jew solventi.
- Ensure the outdoor unit's surroundings are clear of obstructions to allow for proper airflow.
Issolvi l-problemi
Qabel ma tikkuntattja lis-servizz, jekk jogħġbok irreferi għall-kwistjonijiet u s-soluzzjonijiet komuni li ġejjin:
| Problema | Kawża Possibbli | Soluzzjoni |
|---|---|---|
| L-unità ma tixgħel. | No power, remote control batteries dead, unit in standby. | Check power supply, replace remote batteries, press ON/OFF button. |
| Tkessiħ insuffiċjenti. | Dirty air filters, blocked outdoor unit, low refrigerant, wrong mode. | Clean filters, clear obstructions, check for leaks (contact technician), ensure unit is in Cool mode. |
| Storbju mhux tas-soltu. | Loose parts, fan obstruction, normal operating sounds (e.g., refrigerant flow). | Check for loose parts, remove obstructions. If persistent or loud, contact technician. |
| Tnixxija ta 'ilma mill-unità ta' ġewwa. | Clogged drain pipe, improper installation, frozen coil. | Check and clear drain pipe. If issue persists, contact technician. |
Jekk il-problema tippersisti wara li tipprova dawn is-soluzzjonijiet, jekk jogħġbok ikkuntattja tekniku tas-servizz kwalifikat.
Speċifikazzjonijiet
Technical specifications for the Mirage SETCLF120T Mini Split Air Conditioner:
| Karatteristika | Dettall |
|---|---|
| Brand | Mirage |
| Numru tal-Mudell | SETCLF120T |
| Kulur | Abjad |
| Kapaċità | 1 Tun |
| Qawwa tat-tkessiħ | 12000 BTU |
| Voltage | 115 Volts |
| Annual Consumption | 115 Watts (Please refer to energy label for precise annual energy consumption) |
| Livell ta' Storbju | 41 dB |
| Dimensjonijiet tal-Unità ta' Ġewwa (T x W x G) | 80.2 x 20 x 29.5 ċm |
| Piż tal-Unità ta' ġewwa | 9 kg |
| Rating SEER | 12 |
| Karatteristiċi Speċjali | Exterior Protection, Wi-Fi Option (with accessory), Anti-freeze, Remote Control Temperature Sensor, Leak Detector. Note: Product title indicates "Solo Frio" (Single Cooling), while some specifications mention heating/cooling function. This model is primarily for cooling. |
Garanzija u Appoġġ
Mirage provides a manufacturer's warranty for this product. The exact terms and duration of the warranty may vary by region and purchase conditions. Please refer to the warranty card included with your product or contact Mirage customer service for detailed information.
It is important to note that improper installation or unauthorized servicing may void your warranty. Always ensure installation and major maintenance are performed by certified Mirage technicians.
Appoġġ għall-Klijent:
For technical assistance, service requests, or warranty inquiries, please contact Mirage customer support through their official webis-sit jew l-informazzjoni ta' kuntatt ipprovduta fid-dokumentazzjoni tal-prodott tiegħek.
For more information, visit the official Mirage websit: www.mirage.mx