FERUERW 280kg/600lb

FERUERW 600LBs/280KG Electric Magnetic Lock User Manual

Model: 280kg/600lb

1. Introduzzjoni

This manual provides detailed instructions for the installation, operation, and maintenance of your FERUERW 600LBs/280KG Electric Magnetic Lock. Please read this manual thoroughly before installation and use to ensure proper function and safety. This electromagnetic lock is designed for secure access control in various door types.

2. Informazzjoni dwar is-Sigurtà

  • Ensure all electrical connections are made by a qualified professional to prevent electric shock or damage to the device.
  • Ivverifika l-provvista tal-enerġija voltage (DC12V) matches the lock's requirements before connecting.
  • Do not attempt to disassemble or modify the lock, as this may void the warranty and compromise safety.
  • Keep the magnetic lock and armature plate clean and free of debris to maintain optimal holding force.
  • This device is designed for secure access control. Ensure proper installation to prevent unauthorized entry.

3. Prodott Aktarview

The FERUERW 600LBs/280KG Electric Magnetic Lock is constructed from high-strength aluminum, featuring professional hard anodization for corrosion resistance and waterproof performance. It operates silently and includes a built-in reverse current protection device for enhanced safety.

3.1. Karatteristiċi ewlenin

  • Upgrade Material: Made of high-strength aluminum, professionally hard anodized, corrosion-resistant, waterproof, and treated with a special anti-rust process. Operates without noise.
  • Wide Range Of Applications: Suitable for wooden doors, metal doors, glass doors, fireproof doors, and more.
  • Sigurtà: Built-in reverse current protection device ensures higher performance and user safety.
  • NC Mode: Locked while supplied with power.

3.2. Komponenti

FERUERW 600LBs/280KG Electric Magnetic Lock components
Figura 1: FERUERW 600LBs/280KG Electric Magnetic Lock and included hardware. This image displays the main magnetic lock unit, the armature plate, and a bag containing various screws, washers, and an Allen wrench for installation.
Key features of the FERUERW Electric Magnetic Lock
Figura 2: Visual representation of key features including high security, exquisite case design, strong holding force, and corrosion protection.

4. Setup u Installazzjoni

Proper installation is crucial for the optimal performance and security of your magnetic lock. Follow these steps carefully.

4.1. Dimensjonijiet

Dimensions of the FERUERW Electric Magnetic Lock
Figura 3: Detailed dimensions of the magnetic lock and armature plate, showing lengths and widths in inches.

4.2. Passi ta 'installazzjoni

  1. Prepare the Door Frame: Identify the mounting location on the door frame. Ensure the surface is clean and flat.
  2. Mount the Hanging Strip: Unscrew the bolts from the main lock unit to separate the hanging strip. Securely attach the hanging strip to the door frame using the provided screws.
  3. Install the Main Lock Unit: Slide the main magnetic lock unit onto the installed hanging strip. Tighten the side screws to secure it.
  4. Position the Armature Plate: Use the provided sticker or template to mark the drilling points on the door leaf, ensuring it aligns perfectly with the magnetic lock when the door is closed.
  5. Drill Holes and Install Armature Plate: Drill the marked holes. Install the mushroom nut on the back of the door leaf. Attach the armature plate to the door leaf using the M8 screws, adding rubber rings for proper elasticity and adjustment.
  6. Wiring: Connect the power supply (DC12V) to the magnetic lock. Red wire for positive input (+), Black wire for negative input (-). Refer to the wiring diagram in the included instruction sheet for specific connections to your access control system.
Installation diagram for the magnetic lock
Figura 4: An illustration showing the steps for installing the magnetic lock on a door frame and the armature plate on the door.
Important installation considerations
Figura 5: Important notes for installation, including not overtightening armature plate screws, checking voltage, and keeping the lock surface clean.

4.3. Installazzjoni Videos

Vidjo 1: This video demonstrates the installation process of the FERUERW 600LBs/280KG Electric Magnetic Lock, showing how to mount the unit and armature plate.

Vidjo 2: A visual guide to installing the 600lbs Electric Magnetic Electromagnetic Lock, detailing the steps for secure mounting.

5. Istruzzjonijiet Operattivi

The FERUERW Electric Magnetic Lock operates in NC (Normally Closed) mode, meaning it is locked when power is supplied and unlocks when power is removed. This is a fail-safe design, ensuring the door unlocks during a power outage for emergency egress.

  • Qfil: When power is supplied to the unit, the electromagnet activates, creating a strong magnetic bond with the armature plate, thereby locking the door.
  • Il-ftuħ: When power is cut (e.g., via an access control system, button, or power failure), the electromagnet deactivates, releasing the armature plate and allowing the door to open.
  • Dawl Indikatur: A red LED indicates when power is supplied and the lock is engaged.

6. Manutenzjoni

Regular maintenance ensures the longevity and reliable performance of your magnetic lock.

  • Tindif: Periodically wipe the surface of the lock body and armature plate with a clean, dry cloth to remove dust and debris. A clean surface is essential for maintaining strong holding power.
  • Spezzjoni: Regularly check all mounting screws and connections to ensure they are secure. Tighten any loose screws.
  • Armature Plate Adjustment: Ensure the armature plate screws are not fixed too tightly during installation. There should be proper elasticity to facilitate adjustment to the correct position, allowing for full contact with the electromagnet.

7 Issolvi l-problemi

If you encounter issues with your magnetic lock, refer to the following common problems and solutions:

  • Reduced Holding Force:
    • Ensure the magnetic lock and armature plate surfaces are clean and free of any foreign objects or debris.
    • Check for proper alignment between the lock and armature plate. Misalignment can significantly reduce holding force.
    • Verify that the armature plate screws are not overtightened, allowing for slight movement and full contact.
    • Confirm the thickness of the door material. Using a thinner metal than recommended for the armature plate can reduce the effective holding force.
  • Serratura Mhux Qed Tidħol/Tneħħi l-Impenn:
    • Check the power supply. Ensure it is providing the correct DC12V and that all wiring connections are secure.
    • Inspect the indicator light on the lock. If it's not illuminated when power is applied, there may be a wiring issue or power supply problem.
    • If using an access control system, verify its functionality and wiring to the magnetic lock.

8. Speċifikazzjonijiet

ParametruDettall
BrandFERUERW
Isem tal-Mudell280kg/600lb
Tip LockSerratura elettromanjetika
Karatteristika SpeċjaliBla ċavetta
VoltageDC12V
Konsum kurrenti0.11A ~ 0.15A
Forza ta' Żamma280kg / 600lbs
ModalitàNC mode (locked while supplied with power)
MaterjalAluminju
Dimensjonijiet tal-oġġett (L x W x H)10 x 2 x 2 pulzieri
Piż tal-oġġett3.54 liri
Użi RakkomandatiAccess control for wooden, metal, glass, and fireproof doors
Komponenti InklużiElectromagnetic lock, Mounting hardware, Basic wiring/connectors

9. Garanzija

FERUERW Electromagnetic Locks are warranted against defects in material and workmanship while used in normal operating conditions. Please retain your proof of purchase for warranty claims.

10. Appoġġ

For any questions, technical assistance, or support regarding your FERUERW Electric Magnetic Lock, please contact our professional after-sales service team. We are committed to providing excellent customer service.

FERUERW customer service team
Figura 6: The FERUERW customer service team is available to assist with product inquiries and support.

Dokumenti Relatati - 280kg/600lb

Preview Electromagnetic Lock User Manual - FERUERW 280kg/600lb
User manual for the FERUERW 280kg (600lb) electromagnetic lock. Features include MOV surge protection, magnetic bond sensor, door position sensor, bi-color LED status indicator, and anodized aluminum housing. Covers specifications, warranty, and installation with L, LZ, and U-brackets for various door types.
Preview Manwal tal-Utent tas-Serratura Elettromanjetika Secukey
Manwal tal-utent għas-serratura elettromanjetika Secukey, li jiddeskrivi l-karatteristiċi, l-ispeċifikazzjonijiet, l-installazzjoni, u l-informazzjoni dwar il-garanzija. Ikopri l-protezzjoni kontra ż-żidiet fil-vultaġġ tal-MOV, is-senser tal-kuntatt manjetiku, il-monitoraġġ tal-istatus tal-bieb, u l-indikaturi LED.
Preview Gwida għall-Utent tal-BEA MAGLOCKS 600LB: Installazzjoni u Speċifikazzjonijiet tas-Serratura Elettromanjetika
Gwida komprensiva għall-utent għas-serraturi elettromanjetiċi tas-serje BEA MAGLOCKS 600LB. Tkopri l-installazzjoni, l-ispeċifikazzjonijiet, il-prekawzjonijiet, u l-wajers elettriċi għal konfigurazzjonijiet ta' serratura waħda u doppja.
Preview Magnetic Lock Installation Manual - Series Electric Bolt
Comprehensive installation manual for Series Electric Bolt magnetic locks, detailing scope, product benefits, parameters, wiring, and installation diagrams for secure access control.
Preview Gwida għall-Utent tal-BEA UL Maglocks 600LB
Gwida għall-utent għas-serje ta' serraturi elettromanjetiċi UL Maglocks 600LB ta' BEA, li tkopri l-installazzjoni, l-ispeċifikazzjonijiet u l-prekawzjonijiet.