Prity K2 CP

Manwal tal-Utent tal-Istufa tal-Injam Prity K2 CP 10 kW

Model: K2 CP | Brand: Prity

1. Introduzzjoni

This manual provides essential information for the safe and efficient installation, operation, and maintenance of your Prity K2 CP 10 kW wood stove. Please read these instructions carefully before using the appliance and retain them for future reference. Proper adherence to these guidelines will ensure optimal performance and longevity of your stove.

Prity K2 CP Wood Stove with fire burning in the combustion chamber

Stampa 1: Quddiem view of the Prity K2 CP wood stove with a visible fire through the ceramic glass door.

1.1 Prodott Fuqview

The Prity K2 CP is a 10 kW wood-burning stove designed for heating residential spaces. It features a robust construction with a reinforced combustion chamber lined with refractory bricks for heat accumulation and improved combustion temperature. The stove is equipped with heat-resistant ceramic glass, a cast iron grate, and two manual dampers for precise air and flame intensity control. An integrated compartment is provided for storing and drying wood.

1.2 Informazzjoni dwar is-Sigurtà

TWISSIJA: Installazzjoni, aġġustament, alterazzjoni, servizz, jew manutenzjoni mhux xierqa jistgħu jikkawżaw korriment jew ħsara lill-proprjetà. Aqra l-istruzzjonijiet tal-installazzjoni, tat-tħaddim, u tal-manutenzjoni bir-reqqa qabel ma tinstalla jew tagħmel servizz lil dan it-tagħmir.

  • Always ensure adequate ventilation in the room where the stove is installed.
  • Maintain required clearances to combustible materials as specified in local building codes and this manual.
  • Only use recommended fuels (wood, coal). Do not burn plastics, treated wood, or other unsuitable materials.
  • Regularly inspect and clean the flue system to prevent creosote buildup and chimney fires.
  • Żomm it-tfal u l-annimali domestiċi 'l bogħod mill-uċuħ sħan tal-fuklar.
  • Install smoke and carbon monoxide detectors in your home.

2. Setup u Installazzjoni

Installation must be performed by a qualified professional and comply with all local and national building and fire safety regulations.

2.1 Spakkjar u Spezzjoni

Carefully unpack the stove and inspect it for any damage that may have occurred during transit. Report any damage to your supplier immediately. Ensure all components listed in the packing list are present.

2.2 Post u awtorizzazzjonijiet

Choose a suitable location for the stove, ensuring it is on a non-combustible floor or hearth. Maintain the minimum clearances to combustible walls and materials as specified by local regulations and the manufacturer. The flue pipe connection is at the top of the stove.

Prity K2 CP Wood Stove with Ecodesign 2022 and Blm SchV2 labels

Image 2: Prity K2 CP wood stove displaying Ecodesign 2022 and Blm SchV2 certifications, indicating compliance with environmental standards.

2.3 Flue System Connection

Connect the stove to a suitable chimney or flue system with a diameter of 130 mm. Ensure all connections are sealed properly to prevent smoke leakage. The chimney must be in good condition, free of obstructions, and capable of providing adequate draft.

2.4 Initial Firing (Curing)

Before regular use, the stove must be cured to allow the paint and internal components to settle. This process involves several small, low-temperature fires. During curing, some smoke and odor may be emitted; ensure the area is well-ventilated. Avoid high temperatures during the first few fires.

3. Istruzzjonijiet Operattivi

Understanding how to properly operate your Prity K2 CP stove is crucial for safety, efficiency, and comfort.

3.1 Tip ta' Fjuwil

The Prity K2 CP stove is designed to burn wood and coal. For optimal performance and to minimize creosote buildup, use dry, seasoned hardwood. Wood with a moisture content of 20% or less is recommended. Avoid burning:

  • Injam imxarrab jew mhux imħawwar
  • Garbage, plastics, or chemical waste
  • Injam ittrattat jew miżbugħ
  • Likwidi li jaqbdu

3.2 Tixgħel il-Fuklar

  1. Open both the front air supply damper and the smoke damper fully.
  2. Place crumpled paper or natural firelighters on the cast iron grate.
  3. Add a small amount of kindling (small, dry pieces of wood) on top of the firelighters.
  4. Light the firelighters.
  5. Once the kindling is burning well, gradually add larger pieces of wood.
  6. Close the combustion chamber door once the fire is established.

3.3 Kontroll tal-Ajru

The stove is equipped with two manual dampers:

  • Front Air Damper: Located at the front, this controls the primary air supply to the combustion chamber. Open it for ignition and when adding new fuel. Close it partially to reduce the burn rate and conserve fuel.
  • Duħħan Damper: This regulates the intensity of the flame and the draft through the flue. Adjust it to achieve a steady, efficient burn.

Adjusting these dampers allows you to control the heat output and efficiency. A bright, lively flame indicates good combustion. Excessive smoke or a dull, smoldering fire suggests insufficient air or wet fuel.

3.4 Riforniment

When adding more fuel, open the front air damper and smoke damper fully for a few minutes before opening the combustion chamber door. This helps to prevent smoke from entering the room. Carefully place new logs onto the existing embers and close the door. Adjust the dampers once the new fuel has ignited.

4. Manutenzjoni

Regular maintenance is essential for the safe and efficient operation of your Prity K2 CP stove.

4.1 Tneħħija tal-Irmied

Remove ash regularly from the ash pan, typically when it is about two-thirds full. Do not allow ash to build up and touch the bottom of the grate, as this can restrict airflow and damage the grate. Always use a metal container with a tight-fitting lid for ash disposal, as embers can remain hot for days.

4.2 Tindif tal-Ħġieġ

The ceramic glass in the combustion chamber door can become dirty with soot. Clean it when the stove is cold using a specialized glass cleaner for wood stoves or a damp cloth dipped in ash. Avoid abrasive cleaners or tools that could scratch the glass.

4.3 Flue and Chimney Cleaning

The flue pipe and chimney should be inspected and cleaned at least once a year, or more frequently depending on usage and fuel type. Creosote buildup is a fire hazard. This task should be performed by a certified chimney sweep.

4.4 Spezzjoni Ġenerali

Periodically check the door seals for wear and tear. Replace them if they are damaged to ensure an airtight seal. Inspect the refractory bricks for cracks or damage; while minor cracks are normal, severely damaged bricks should be replaced.

5 Issolvi l-problemi

This section addresses common issues you might encounter with your wood stove.

ProblemaKawża PossibbliSoluzzjoni
Id-duħħan jidħol fil-kamraInsufficient draft, blocked chimney, opening door too quickly, wet fuel.Check chimney for blockages, ensure dampers are open, pre-heat flue, use dry fuel, open door slowly.
Produzzjoni fqira tas-sħanaWet fuel, insufficient air, stove too small for space, excessive ash.Use dry fuel, adjust air dampers, remove ash, ensure stove size is appropriate.
Rapid burning of fuelToo much air supply, faulty door seal.Agħlaq l-arja dampers partially, check and replace door seals if necessary.
Il-ħġieġ jiswed malajrWet fuel, low burning temperature, insufficient air wash.Use dry fuel, ensure adequate air supply, clean glass regularly.

6. Speċifikazzjonijiet

Technical data for the Prity K2 CP 10 kW Wood Stove.

KaratteristikaValur
BrandPrity (BALKAN ENERGY)
MudellK2 CP
Dimensjonijiet tal-Prodott (H x W x D)810 x 500 x 510 mm
Combustion Chamber Dimensions (H x W x D)400 x 365 x 410 mm
Qawwa tat-Tisħin10 kW
Żona tal-wiċċ tat-tisħinAppross. 57 m²
Effiċjenza75-80%
Dijametru tal-Pajp tal-Flue130 mm
Pożizzjoni taċ-ĊumnijaFuq
Tip ta' FjuwilWood, Coal
MaterjalStainless Steel (Body), Cast Iron (Grate, Top Plate), Ceramic Glass
KulurGrafita l-Iswed
Piż90 kg
Klassi tal-EnerġijaA
ĊertifikazzjoniCE, EN Standard
Numru ta' Reġistrazzjoni EPREL1271282

7. Garanzija u Appoġġ

For warranty information, technical support, or spare parts, please contact the manufacturer or your retailer.

Please have your model number (K2 CP) and purchase date available when contacting support.

Dokumenti Relatati - K2 CP

Preview Bojlers Prity: Deskrizzjoni Teknika, Installazzjoni, u Manwal tat-Tħaddim
Gwida komprensiva għall-bojlers residenzjali Prity, li tkopri l-ispeċifikazzjonijiet tekniċi, il-proċeduri ta' installazzjoni, l-istruzzjonijiet tat-tħaddim, il-manutenzjoni, u s-soluzzjoni tal-problemi għal mudelli ta' fjuwil solidu u pellet.
Preview Truma Combi (E) Operating Instructions and Technical Guide
Comprehensive operating instructions and technical specifications for the Truma Combi (E) caravan and motorhome heater. Covers installation, operation, safety, maintenance, troubleshooting, and warranty information.
Preview Speċifikazzjonijiet Tekniċi tal-Heater Kummerċjali tal-Pixxina Lochinvar Copper-Fin II CP-SPEC-10
Speċifikazzjonijiet tekniċi dettaljati għall-heater kummerċjali tal-pixxini Lochinvar Copper-Fin II, mudell CP-SPEC-10, li jkopru l-karatteristiċi, il-kostruzzjoni, il-kontrolli, u ċ-ċertifikazzjonijiet għal applikazzjonijiet ta' pixxini u spa.
Preview Istruzzjonijiet tal-Operazzjoni u Gwida għas-Soluzzjoni tal-Problemi tat-Truma CP plus
Istruzzjonijiet komprensivi għat-tħaddim u gwida għas-soluzzjoni tal-problemi għall-pannell tal-kontroll Truma CP plus, li jkopru l-installazzjoni, it-tħaddim, il-funzjonijiet, u d-dijanjosi tal-ħsarat għal ħiters Combi tal-gass u tad-diżil, kif ukoll sistemi tal-arja kondizzjonata.
Preview Truma AquaGo Decalcification Instructions and Maintenance Guide
Detailed instructions for decalcifying your Truma AquaGo RV water heater. This guide covers procedures for both Analog Dial and CP plus controller models, including troubleshooting steps for common issues like being stuck in clean mode.