1. Introduzzjoni

The N1 Critical N1C.L1500 is a high-performance 1500VA/1350W Uninterruptible Power Supply (UPS) designed to provide reliable power protection for critical electronic equipment. Featuring advanced Lithium-Ion (LiFePO4) battery technology, this UPS offers extended battery life, higher power density, and improved thermal performance compared to traditional VRLA battery systems. It supports both rackmount and tower configurations, making it versatile for various IT environments.

2. Istruzzjonijiet tas-Sigurtà

Please read and follow all safety instructions carefully before installing, operating, or servicing the UPS. Failure to comply with these instructions may result in electric shock, fire, or serious injury.

3. Kontenut tal-Pakkett

Iċċekkja li l-oġġetti kollha huma preżenti meta tiftaħ il-pakkett:

4. Prodott Aktarview

4.1 Panel ta 'Quddiem

The front panel features the LCD display and control buttons for monitoring and configuring the UPS.

N1 Critical N1C.L1500 UPS Front View

Figura 4.1: Quddiem view of the N1 Critical N1C.L1500 UPS, showing the integrated LCD display and control buttons.

N1 Critical N1C.L1500 UPS LCD Display

Figure 4.2: Close-up of the N1 Critical N1C.L1500 UPS LCD display, indicating input voltage, battery status, and operational modes.

4.2 Panel ta 'wara

The rear panel provides all necessary connections for input power, protected equipment, and communication interfaces.

N1 Critical N1C.L1500 UPS Rear View with Outlets and Ports

Figura 4.3: Wara view of the N1 Critical N1C.L1500 UPS, showing six NEMA 5-15R outlets, AC input, circuit protector, USB port, EPO port, and an intelligent slot.

5. Setup

5.1 Tqegħid

The N1C.L1500 UPS can be installed in either a rackmount or tower configuration.

Ensure the installation location is well-ventilated, free from excessive heat or moisture, and has stable ambient temperatures.

5.2 Konnessjoni mal-Enerġija

  1. Connect the supplied input power cord to the AC Input port on the rear panel of the UPS.
  2. Plug the other end of the input power cord into a grounded 120V AC wall outlet.

5.3 Tagħmir ta' Konnessjoni

  1. Ensure all equipment to be connected to the UPS is turned off.
  2. Plug your critical equipment (computers, servers, network devices) into the NEMA 5-15R outlets on the rear panel of the UPS.
  3. Do not connect surge suppressors or power strips to the UPS outlets, as this may overload the UPS.

5.4 L-Istartjar Inizjali

  1. After connecting the UPS to utility power and your equipment, press and hold the power button on the front panel for a few seconds until the UPS powers on.
  2. The LCD display will illuminate, and the UPS will perform a self-test.
  3. Once the self-test is complete, the UPS will enter normal operating mode, providing conditioned power to your connected devices.

6. Istruzzjonijiet Operattivi

6.1 Power On/Off

6.2 Nifhmu d-Displej LCD

The LCD display provides real-time information about the UPS status, including input/output voltage, livell ta 'ċarġ tal-batterija, perċentwali tat-tagħbijatage, and various operational modes or warnings. Refer to Figure 4.2 for a visual reference.

6.3 Operazzjoni ta' Backup tal-Batterija

Waqt qawwa outage jew volum sinifikantitage fluctuation, the UPS will automatically switch to battery power, providing continuous power to connected equipment. An audible alarm may sound, and the display will indicate battery mode. The duration of backup power depends on the connected load and battery charge level.

6.4 Karatteristiċi ta' Komunikazzjoni

7. Manutenzjoni

7.1 Kura tal-Batterija

The N1C.L1500 utilizes Lithium-Ion (LiFePO4) batteries, which offer a significantly longer lifespan (10-15 years) and better thermal tolerance compared to traditional lead-acid batteries. These batteries are not user-replaceable. For battery service or replacement, contact qualified service personnel.

7.2 Tindif

Periodically clean the exterior of the UPS with a soft, dry cloth. Ensure ventilation openings are free from dust and debris to maintain proper airflow. Do not use liquid or aerosol cleaners.

7.3 Ħażna

If storing the UPS for an extended period, ensure it is fully charged before storage. Store in a cool, dry environment. Recharge the UPS every 3-6 months to maintain battery health.

8 Issolvi l-problemi

This section provides solutions to common issues you may encounter with the UPS.

ProblemaKawża PossibbliSoluzzjoni
L-UPS ma jixgħelxNo AC input power; UPS not fully charged; Power button not pressed correctly.Check AC power connection and outlet; Allow UPS to charge for several hours; Press and hold power button firmly.
L-UPS ikun fil-modalità tal-batterija ta' spissQawwa tal-utilità instabbli; Is-setting tas-sensittività huwa għoli wisq.Check utility power quality; Adjust UPS sensitivity setting via software (if available).
Twissija ta' tagħbija żejdaConnected equipment exceeds UPS capacity.Disconnect non-essential equipment; Reduce the total load to within UPS capacity.
Battery fault indicatorKwistjoni interna tal-batterija.Contact N1 Critical support for assistance. Do not attempt to replace the battery yourself.

9. Speċifikazzjonijiet

Technical specifications for the N1 Critical N1C.L1500 UPS:

10. Garanzija u Appoġġ

For warranty information, technical support, or service inquiries, please refer to the official N1 Critical website or contact their customer service department. Keep your purchase receipt for warranty validation.

Dokumenti Relatati - N1C.L1500

Preview Riello HPM 2 Series Modular UPS: High Efficiency, Reliability, and Scalability
The Riello HPM 2 Series is a highly efficient, reliable, and scalable modular Uninterruptible Power Supply (UPS) system designed for critical loads in data centers, industrial environments, and healthcare facilities. Featuring advanced technologies like HECO Mode and LBS Function, it offers flexible power expansion and intelligent management for optimal performance and cost savings.
Preview Riello UPS NextEnergy: High-Efficiency, Scalable Power Protection
Discover the Riello UPS NextEnergy series, a range of advanced Uninterruptible Power Supplies (UPS) designed for mission-critical applications. Offering up to 97% efficiency, transformerless design, and flexible installation, NextEnergy ensures reliable power for data centers, communication networks, and industrial facilities. Explore features like Active Eco mode, peak shaving, and smart battery management.
Preview UPS Vertiv Liebert GXT5: Protezzjoni tal-Enerġija Intelliġenti u Effiċjenti | Product Overview
Esplora s-serje UPS Vertiv Liebert GXT5, li toffri protezzjoni tal-enerġija intelliġenti u effiċjenti għal applikazzjonijiet kritiċi għall-missjoni. Dan aktar minnview dettalji dwar il-karatteristiċi, l-ispeċifikazzjonijiet, il-familja tiegħuview, pakketti ta' servizz, aċċessorji, u għażliet ta' mmuntar, li jenfasizzaw id-disinn kompatt tiegħu, l-effiċjenza għolja, u l-kapaċitajiet ta' ġestjoni avvanzata.
Preview Manwal tat-Tħaddim tal-UPS tas-Serje N1C LK 5-10kVA
Manwal komprensiv tat-tħaddim għas-Sistemi ta' Enerġija Mingħajr Interruzzjoni (UPS) N1C LK-Series 5-10kVA. Ikopri l-installazzjoni, il-karatteristiċi, il-modi ta' tħaddim, is-soluzzjoni tal-problemi, u l-ispeċifikazzjonijiet għal protezzjoni affidabbli tal-enerġija kritika.
Preview UPS Vertiv Liebert GXT5: Protezzjoni tal-Enerġija ta' 15-20kVA għal Applikazzjonijiet Kritiċi għall-Missjoni
Esplora s-serje UPS Vertiv Liebert GXT5, li toffri 15-20kVA ta' protezzjoni tal-enerġija intelliġenti, effiċjenti u affidabbli għal applikazzjonijiet kritiċi għall-missjoni. Il-karatteristiċi jinkludu konverżjoni doppja online, fattur ta' enerġija unitarju, effiċjenza għolja, u kapaċitajiet ta' ġestjoni avvanzata.
Preview Schrack AVARA Multi Power Modular UPS User Manual: 15/25/42 kW to 1 MW
Comprehensive user manual for the Schrack AVARA Multi Power modular UPS series (USMPM 10 – 100 kVA), covering specifications, applications, system configurations, and technical data for models ranging from 15 kW to 1 MW. Essential guide for critical load protection in data centers, e-business, and telecommunications.