Mirage SETCLF121T Mini Split Air Conditioner Life 12 Plus User Manual

Introduzzjoni

This manual provides essential information for the safe and efficient operation of your Mirage SETCLF121T Mini Split Air Conditioner Life 12 Plus. Please read it thoroughly before installation and use, and retain it for future reference. The Mirage Life 12 Plus is a conventional (non-inverter) cooling-only unit designed for superior efficiency within its category, offering advanced features for enhanced comfort.

Informazzjoni dwar is-Sigurtà

Istruzzjonijiet Importanti dwar is-Sigurtà:

Kontenut tal-Pakkett

Meta tiftaħ il-pakkett, ivverifika li l-oġġetti li ġejjin huma inklużi:

Prodott Overview

The Mirage SETCLF121T Life 12 Plus Mini Split Air Conditioner is designed for efficient cooling. Key features include:

Mirage SETCLF121T Mini Split Air Conditioner front view

Figura 1: Quddiem view of the Mirage SETCLF121T indoor unit, showcasing its sleek white design and branding.

Mirage SETCLF121T Mini Split Air Conditioner angled view

Figura 2: Angolat view of the indoor unit, highlighting its compact form factor.

Mirage SETCLF121T Mini Split Air Conditioner remote control

Figure 3: The advanced remote control with a large illuminated display for easy operation and status monitoring.

Mirage SETCLF121T Mini Split Air Conditioner dimensions

Figure 4: Diagram illustrating the dimensions of the indoor unit: 80.2 cm (length) x 20 cm (width) x 29.5 cm (height).

Setup u Installazzjoni

Installazzjoni Professjonali Rakkomandata:

The installation of a mini split air conditioner involves electrical wiring, refrigerant line connections, and proper drainage setup. For safety and optimal performance, it is highly recommended that installation be performed by a certified HVAC technician.

General Installation Steps (for reference only):

  1. Tqegħid tal-Unità ta' Ġewwa: Select a location that allows for even air distribution, proper drainage, and easy access for maintenance.
  2. Tqegħid tal-Unità ta' Barra: Choose a stable, well-ventilated area away from direct sunlight and heat sources, ensuring sufficient clearance for airflow.
  3. Toqba tat-Tħaffir fil-Ħajt: Create a hole through the wall for refrigerant piping, drainage hose, and electrical cables.
  4. Konnessjoni tal-Linja tar-Refriġerant: Connect the copper refrigerant lines between the indoor and outdoor units, ensuring proper flaring and tightening to prevent leaks.
  5. Wiring Elettriku: Connect the power supply and communication cables according to the wiring diagram provided in the full installation manual.
  6. Konfigurazzjoni tad-Drenaġġ: Ensure the drainage hose is properly sloped to allow for continuous water flow away from the unit.
  7. Vacuum cleaner u Iċċarġjar: Evacuate the refrigerant lines to remove air and moisture, then check for leaks and charge with refrigerant if necessary.
  8. Test Run: Perform a test run to ensure all functions operate correctly and the unit cools effectively.

Istruzzjonijiet Operattivi

Your Mirage SETCLF121T is controlled via the included remote control. The remote features an illuminated display showing the current status and settings.

Funzjonijiet tal-Kontroll mill-bogħod:

Kontroll tal-Wi-Fi (Mhux obbligatorju): If the optional Wi-Fi harness and interface are installed, you can control and monitor your unit using a compatible smartphone application. Refer to the Wi-Fi module's specific instructions for setup and usage.

Manutenzjoni

Manutenzjoni regolari tiżgura l-lonġevità u l-effiċjenza tal-arja kondizzjonata tiegħek.

1. Tindif tal-Filtru tal-Arja:

2. Unit Exterior Cleaning:

3. Seasonal Checks:

Issolvi l-problemi

Qabel ma tikkuntattja lis-servizz, iċċekkja l-kwistjonijiet komuni li ġejjin:

ProblemaKawża PossibbliSoluzzjoni
L-unità ma tixgħelNo power supply; Remote control batteries low; Circuit breaker tripped.Iċċekkja l-konnessjoni tal-enerġija; Ibdel il-batteriji tar-remote; Irrisettja ċ-ċirkwit interruttur.
Tkessiħ insuffiċjentiDirty air filters; Doors/windows open; Temperature setting too high; Obstruction at air inlet/outlet.Clean air filters; Close doors/windows; Lower temperature setting; Remove obstructions.
Ħoss mhux tas-soltuLoose parts; Unit not level; Debris in outdoor unit.Check for loose components; Ensure unit is level; Clear debris from outdoor unit. If noise persists, contact service.
Tnixxija ta' ilma mill-unità ta' ġewwaClogged drainage hose; Improper installation.Check and clear drainage hose; Contact installer for inspection.
Il-kontroll mill-bogħod ma jaħdimxBatteriji mejta jew imdaħħla ħażin; Ostruzzjoni bejn ir-remote u l-unità.Replace batteries; Ensure clear line of sight to indoor unit receiver.

If the problem persists after attempting these solutions, please contact authorized service personnel.

Speċifikazzjonijiet

SpeċifikazzjoniDettall
BrandMirage
MudellSETCLF121T
Fattur tal-FormolaMini Split
Kapaċità1 Tun
Qawwa tat-tkessiħ12000 Unità Termali Brittanika (BTU)
Voltage230 Volts
Livell ta' Storbju41 dB
Dimensjonijiet tal-Unità ta' Ġewwa (T x W x G)80.2 x 20 x 29.5 ċm
Piż tal-Oġġett (Unità ta' Ġewwa)9 Kilogrammi
Proporzjon tal-Effiċjenza Enerġetika Staġjonali (SEER)12
BEE Rating5 Star
Karatteristika SpeċjaliCooling Function Only (as per product title)

Garanzija u Appoġġ

Your Mirage SETCLF121T Mini Split Air Conditioner comes with a manufacturer's warranty. Please refer to the included warranty card for specific terms, conditions, and duration of coverage. Retain your proof of purchase for warranty claims.

For technical support, service requests, or inquiries regarding your product, please contact Mirage customer service through their official website or the contact information provided in your warranty documentation. Ensure to have your model number (SETCLF121T) and purchase date available when contacting support.

Dokumenti Relatati - SETCLF121T

Preview Mirage LIFE 12 Air Conditioner: User and Installation Manual
Comprehensive user and installation manual for the Mirage LIFE 12 series air conditioners, covering operation, features, installation procedures, troubleshooting, and technical specifications.
Preview Mirage LIFE 12+ Air Conditioner User and Installation Manual
Comprehensive user and installation manual for the Mirage LIFE 12+ air conditioner (Model V.1221). Covers operation, installation, troubleshooting, technical specifications, and warranty.
Preview Mirage B-34 VHF Amplifier: Manwal tal-Utent u Speċifikazzjonijiet
Explore the features, specifications, installation, and troubleshooting for the Mirage B-34 VHF linear power amplifier, designed for 144-148 MHz operation with handheld transceivers.
Preview Manual de Usuario e Instalación Dispensador de Agua Mirage DISX30 Series (MDD30HD)
Guía completa de usuario e instalación para el dispensador de agua Mirage DISX30 Series (Modelo MDD30HD). Cubre operación, mantenimiento, solución de problemas y garantía.
Preview mirage Android TV-Box M8 Bedienungsanleitung
Umfassende Bedienungsanleitung für die mirage Android TV-Box Modell M8. Erfahren Sie mehr über Installation, Funktionen, Einstellungen, Fehlerbehebung und technische Spezifikationen.
Preview Manwal tal-Utent tat-Trasmettitur Mobbli Dilettanti Mirage MX-36HP3 AM ta' 10 Metri
Manwal tal-utent għat-Trasmettitur Mobbli Dilettant Mirage MX-36HP3 AM ta' 10 Metri, li jkopri l-ispeċifikazzjonijiet, l-installazzjoni u t-tħaddim.