1. Informazzjoni Importanti dwar is-Sigurtà
Please read this manual thoroughly before installation and operation. Keep this manual in a safe place for future reference.
- This device is designed to detect both smoke and carbon monoxide.
- L-installazzjoni għandha titwettaq minn elettriċista kwalifikat jekk m'intix familjari mal-wajers elettriċi.
- Do not paint the device. Paint can clog the openings and interfere with sensor operation.
- Test the alarm weekly to ensure proper function.
- Replace the 9V backup battery annually, or when the low battery warning sounds.
2. Prodott Aktarview
The X-Sense XP04 is a hardwired combination smoke and carbon monoxide detector designed for comprehensive home safety. It features advanced photoelectric smoke and electrochemical CO sensors for accurate detection.

This detector is AC powered and includes a replaceable 9V battery backup, ensuring continuous monitoring even during power outages. It can be interconnected with up to 18 compatible X-Sense hardwired alarms, providing full coverage throughout your home.


Prodott Overview Video
Dan il-filmat jipprovdi viżwali fuqview of the X-Sense XP04 Hardwired Combination Detector, demonstrating its features and components.
3. Setup u Installazzjoni
The X-Sense XP04 detector is designed for easy installation. All necessary mounting hardware is included.
Passi ta' Installazzjoni:
- Ipprepara l-post tal-immuntar: Ensure the power is off at the circuit breaker before beginning installation. Select a location in accordance with local codes and the provided guidelines.
- Installa l-Bracket tal-Immuntar: Secure the mounting bracket to the ceiling or wall using the provided screws and anchor plugs.
- Qabbad il-Wiring: Connect the AC hardwired cables (black, white, red) to your household wiring. The red wire is for interconnection with other compatible alarms.
- Installa l-Backup tal-Batterija: Insert the 9V backup battery into the battery compartment.
- Waħħal id-Ditekter: Align the detector with the mounting bracket and twist clockwise until it locks securely into place.
- Irrestawra l-Enerġija: Turn on the power at the circuit breaker. The detector will perform a self-test.

Interconnection for Full Coverage
This detector supports interconnection with up to 18 X-Sense 2-in-1 hardwired alarms. When one interconnected alarm is triggered, all connected alarms will sound simultaneously, providing early warning throughout your home.


4. Istruzzjonijiet Operattivi
Status tal-Indikatur LED:
- LED aħdar: Indicates normal operation and AC power.
- LED isfar: Indicates a fault or low battery condition.
- LED aħmar: Indicates an alarm (smoke or carbon monoxide detected).
Ittestjar tal-allarm:
Press and hold the 'Test/Silence' button located on the center of the detector. The alarm will sound, and the LED indicator will flash. Release the button to stop the test. Test the alarm weekly.

Issikket l-allarm:
In case of a non-emergency alarm (e.g., cooking fumes), press the 'Test/Silence' button to temporarily silence the alarm. The alarm will automatically reset after a few minutes if the air clears. If the hazard persists, the alarm will reactivate.
5. Manutenzjoni
Sostituzzjoni tal-batterija:
The 9V backup battery should be replaced annually. When the battery is low, the detector will chirp and the yellow LED will flash. To replace the battery:
- Twist the detector counter-clockwise to remove it from the mounting bracket.
- Iftaħ il-kompartiment tal-batterija.
- Remove the old 9V battery and insert a new one, ensuring correct polarity.
- Close the battery compartment and reattach the detector to the mounting bracket by twisting clockwise.
- Test the alarm after battery replacement.
Tindif:
Clean your detector at least once a month to remove dust and debris. Use a soft brush or a vacuum cleaner with a soft brush attachment to clean the vents and cover. Do not use water, cleaners, or solvents.
6 Issolvi l-problemi
| Problema | Kawża Possibbli | Soluzzjoni |
|---|---|---|
| Alarm chirps periodically (Yellow LED flashes) | Batterija baxxa | Replace the 9V backup battery. |
| Alarm sounds without apparent smoke/CO | Dust, high humidity, cooking fumes, or chemical vapors | Clean the detector, ventilate the area, or relocate if false alarms persist due to environmental factors. |
| L-allarm ma jdoqqx waqt it-test | No power, faulty battery, or device malfunction | Check AC power, replace battery, or contact customer support if issues persist. |
| Red LED flashes, but no alarm sound | Faulty speaker or internal malfunction | Ikkuntattja l-appoġġ tal-klijent għall-assistenza. |
7. Speċifikazzjonijiet
- Ditta: X-Sense
- Mudell: XP04
- Sors tal-Enerġija: AC (Hardwired) with 9V Battery Backup
- Dimensjonijiet tal-Prodott: 5.5"D x 5.5"W x 1.5"H
- Piż tal-oġġett: 4.58 liri (madwar 2.08 kg)
- Volum tal-allarm: 85 dB f'10 piedi
- Tip ta' Sensor: Fotoelettriku (Duħħan), Elettrokimiku (Monossidu tal-Karbonju)
- Materjal: Polikarbonat
- Interkonnessjoni: Up to 18 compatible X-Sense hardwired units
- It-tul tal-ħajja: Sa 10 snin
- Komponenti Inklużi: 1 × User Manual, 2 × Screws and Anchor Plugs, 1 × 9 V Backup Battery, 1 × AC Hardwired Cable, 1 × Smoke and Carbon Monoxide Alarm XP04 (per unit in pack)
8. Garanzija u Appoġġ
X-Sense provides the following support for your XP04 detector:
- Garanzija ta' Flus lura: 60 jum
- Garanzija tal-Kwalità: 5-sena
- Appoġġ Tekniku: Ħajja
For technical assistance, warranty claims, or further information, please visit the official X-Sense websit jew ikkuntattja lid-dipartiment tas-servizz tal-konsumatur tagħhom.