Introduzzjoni
This manual provides essential information for the safe and efficient operation of your Optimus Instant Water Heater, Model OI-05 B Gas L.P. This appliance is designed to provide continuous hot water on demand, offering efficiency and convenience for a single service point. Please read these instructions thoroughly before installation and use, and retain them for future reference.
Key features include continuous hot water flow, automatic ignition upon hot water demand, and compatibility with both high and low water pressure systems.
Informazzjoni dwar is-Sigurtà
Istruzzjonijiet Importanti dwar is-Sigurtà:
- L-installazzjoni għandha titwettaq minn professjonist kwalifikat skont il-kodiċijiet u r-regolamenti lokali kollha.
- Ensure adequate ventilation for the appliance to prevent carbon monoxide buildup.
- Taħżinx materjali fjammabbli ħdejn il-water heater.
- Regularly inspect gas connections for leaks. Use a soapy water solution, never an open flame.
- Do not block the exhaust vent.
- Żomm it-tfal u l-annimali domestiċi 'l bogħod mill-apparat waqt it-tħaddim.
- In case of gas odor, immediately shut off the gas supply, open windows, and contact a qualified technician.
Prodott Overview
The Optimus OI-05 B is an instant water heater designed for indoor installation, providing hot water for one service point. It operates on LP (Liquid Propane) gas and features a compact design for wall mounting.

Immaġni: Quddiem view of the Optimus Instant Water Heater, Model OI-05 B. The unit is white with the Optimus logo at the top and a control knob at the bottom.

Immaġni: Angolat view of the Optimus Instant Water Heater, showing the side vents and the compact design. The unit is white with the Optimus logo at the top and a control knob at the bottom.
The unit's dimensions are approximately 30 cm (length) x 13.5 cm (width) x 48.8 cm (height), making it suitable for various indoor spaces.

Immaġni: Diagram illustrating the dimensions of the Optimus Instant Water Heater. The height is 48.8 cm, length is 30 cm, and width is 13.5 cm.
Setup u Installazzjoni
The Optimus OI-05 B water heater is designed for indoor wall-mounted installation. Due to the nature of gas and water connections, installazzjoni professjonali hija rakkomandata ħafna biex tiġi żgurata s-sigurtà u l-funzjonalità xierqa.
Passi ta' Installazzjoni (Fuqview):
- Għażla tal-Post: Choose a well-ventilated indoor location, away from flammable materials, with easy access to water and gas lines. The unit is designed for wall mounting.
- Immuntar: Securely mount the water heater to a sturdy wall using appropriate hardware. Ensure it is level.
- Konnessjonijiet tal-Ilma: Connect the cold water inlet and hot water outlet pipes. Ensure all connections are tight and leak-free.
- Konnessjoni tal-gass: Connect the LP gas supply line to the water heater. Use appropriate gas-rated fittings and ensure a leak-free connection. Perform a leak test with soapy water.
- Ventilazzjoni: Ensure the exhaust vent is properly installed and unobstructed, directing combustion gases safely outdoors.
- Istartjar Inizjali: After all connections are secure and checked, slowly open the gas supply valve. Open a hot water faucet to allow water to flow through the unit and purge air from the system.

Immaġni: The Optimus Instant Water Heater mounted on a brick wall, demonstrating a typical indoor installation. The unit is white and blends with the wall.
Refer to the detailed installation guide provided with the product packaging for specific diagrams and instructions.
Istruzzjonijiet Operattivi
The Optimus OI-05 B water heater features automatic ignition, simplifying its operation.
Operazzjoni Bażika:
- Ensure Gas Supply: Verify that the LP gas supply valve is open.
- Fluss tal-Ilma: Open any hot water faucet in your home. The water heater will detect the flow and automatically ignite to heat the water.
- Aġġustament tat-temperatura: Use the control knob on the front of the unit to adjust the desired water temperature. Turning the knob towards the '+' symbol increases the temperature, and towards the '-' symbol decreases it.
- Itfi: When the hot water faucet is closed, the water heater will automatically turn off.
The unit is designed to work effectively with both high and low water pressure, ensuring consistent performance.
Manutenzjoni
Regular maintenance ensures the longevity and efficient operation of your Optimus Instant Water Heater. It is recommended to have the unit inspected by a qualified technician annually.
Kontrolli ta' Rutina:
- Ventilazzjoni: Ensure the area around the water heater is clear and the exhaust vent is free from obstructions.
- Konnessjonijiet tal-gass: Periodically check gas connections for any signs of leaks (e.g., using a soapy water solution).
- Tnixxijiet tal-Ilma: Inspect water pipes and connections for any drips or leaks.
- Tindif: Żomm il-barra tal-unità nadifa. Tużax prodotti tat-tindif li joborxu.
For any internal maintenance or repairs, always contact a certified service professional.
Issolvi l-problemi
Din it-taqsima tindirizza kwistjonijiet komuni li tista’ tiltaqa’ magħhom bil-water heater tiegħek.
| Problema | Kawża Possibbli | Soluzzjoni |
|---|---|---|
| L-ebda ilma sħun / L-unità ma tixgħelx |
|
|
| Ilma mhux sħun biżżejjed |
|
|
| L-unità tnixxi l-ilma |
|
|
If troubleshooting steps do not resolve the issue, contact customer support or a certified technician.
Speċifikazzjonijiet
| Brand | Optimus |
| Numru tal-Mudell | OI-05 B Gas L.P. |
| Kapaċità | 5 Liters/minute (for 1 service) |
| Sors tal-Enerġija | Liquid Propane (LP Gas) |
| Stil ta 'installazzjoni | Installazzjoni fuq ġewwa |
| Tip ta 'Immuntar | Mount Wall |
| Dimensjonijiet tal-Prodott (L x W x H) | 30 ċm x 13.5 ċm x 48.8 ċm |
| Piż tal-oġġett | 5.58 kg |
| ASIN | B0B191GCX7 |
Garanzija u Appoġġ
For warranty information, technical support, or service requests, please refer to the documentation included with your product or contact Optimus customer service directly. Keep your purchase receipt as proof of purchase for warranty claims.
Manifattur: Optimus
Għal aktar għajnuna, żur il- Optimus Brand Store.