ResMed AirFit F30

Manwal tal-Istruzzjonijiet tas-Sistema tal-Qafas ResMed AirFit F30

Model: AirFit F30

Informazzjoni Importanti dwar is-Sigurtà

Magnetic Interference Warning:

Keep the mask magnets at a safe distance of at least 6 inches (150 mm) away from implants or medical devices that may be adversely affected by magnetic interference. This warning applies to you or anyone in close physical contact with your mask. The magnets are located in the frame and lower headgear clips, with a magnetic field strength of up to 400mT. While designed to connect securely, they may inadvertently detach during sleep.

Kontra-indikazzjonijiet:

Masks with magnetic components are contraindicated for use by patients, or anyone in close physical contact with the patient while using the mask, who have the following:

  • Impjanti mediċi attivi li jinteraġixxu ma' kalamiti (eż. pacemakers, defibrillaturi kardjoverter impjantabbli (ICD), newrostimulaturi, shunts tal-fluwidu ċerebrospinali (CSF), pompi tal-insulina/infużjoni).
  • Impjanti/oġġetti metalliċi li fihom materjal ferromanjetiku (eż., klipps/apparati li jfixklu l-fluss tal-anevriżmi, kojls emboliċi, stents, valvi, elettrodi, impjanti biex jirrestawraw is-smigħ jew il-bilanċ b'kalamiti impjantati, impjanti okulari, biċċiet metalliċi fl-għajn).

Prodott Overview

The ResMed AirFit F30 Frame System is designed for use with the ResMed AirFit F30 full-face CPAP mask. This system provides a relaxed fit and is intended to support sleep apnea therapy. It features a minimal-contact design, positioning the cushion under the nose, which can be beneficial for individuals who wear glasses, watch television, or sleep on their side.

ResMed AirFit F30 Frame System, showing the clear mask frame, cushion, and elbow connector.

Image: The ResMed AirFit F30 Frame System, featuring its clear, minimal-contact design with blue accents on the side clips and a white elbow connector.

Komponenti

The ResMed AirFit F30 Frame System includes the following components:

  • Sistema tal-qafas
  • Minkeb
  • Full-face mask cushion (designed specifically for the AirFit F30 mask)

Note: The AirFit F30 headgear is not included with this frame system replacement.

Sploda view of ResMed AirFit F30 mask components, including frame, cushion, elbow, and headgear clips.

Immaġni: Sploda view illustrating the individual components of the AirFit F30 Frame System, including the frame, cushion, elbow, and headgear clips, separated for clarity.

Twaqqif u Twaħħil

To ensure effective therapy and comfort, proper setup and fitting of your AirFit F30 Frame System are essential.

  1. Iċċekkja d-Daqs tal-Kuxxin: Verify that you have the correct cushion size for your face. The size is typically indicated on the cushion itself.
  2. Hands holding the ResMed AirFit F30 mask, pointing to the 'Cushion Size M' label.

    Image: Hands holding the AirFit F30 mask, with an arrow pointing to the 'Cushion Size M' indicator on the mask frame, emphasizing the importance of checking the size.

  3. Arma Komponenti: Attach the cushion to the frame system and connect the elbow. Ensure all connections are secure.
  4. Attach Headgear (Not Included): If you are replacing an existing frame system, attach your AirFit F30 headgear to the frame. The magnetic clips on the frame are designed for easy attachment and detachment of the headgear.
  5. Pożizzjona l-Maskra: Place the mask on your face. The minimal-contact design positions the cushion under your nose, covering both the nose and mouth area without obstructing your field of vision.
  6. Adjust Headgear: Adjust the headgear straps to achieve a comfortable and secure fit. The mask should feel snug but not overly tight. Avoid overtightening, as this can cause discomfort and leaks.
  7. Woman wearing the ResMed AirFit F30 mask, showing proper fit and minimal facial contact.

    Image: A woman wearing the AirFit F30 mask, demonstrating its minimal-contact design and how it sits comfortably on the face, allowing for clear vision.

    Ġenb view of a woman wearing the ResMed AirFit F30 mask connected to CPAP tubing.

    Immaġni: Naħa waħda view of a woman wearing the AirFit F30 mask, showing the connection to the CPAP tubing and the overall profile of the mask during use.

  8. Iċċekkja għal Tnixxijiet: While your CPAP device is running, check for any air leaks around the edges of the mask. Make minor adjustments to the headgear straps as needed to seal any leaks.

Operazzjoni

Once properly fitted, the ResMed AirFit F30 Frame System operates as part of your full-face CPAP mask setup. Its design is intended to provide comfort during therapy, particularly for users who prefer a mask that does not cover the bridge of the nose. The under-the-nose cushion allows for activities like reading or watching TV before sleep and accommodates side sleepers.

Manutenzjoni u Tindif

Regular cleaning and maintenance are crucial for the hygiene and longevity of your AirFit F30 Frame System.

Daily Care Instructions:

  • Ibdel meta jkun hemm sinjali ta’ deterjorament.
  • Jekk meħtieġ, imsaħ in-naħa ta' barra tal-fowm b'imsaħ tas-CPAP jew b'imsaħ simili mingħajr alkoħol.
  • Imtedd ċatt fuq xugaman biex jinxef bl-arja.

Evita dan li ġej:

  • Tesponix għad-dawl tax-xemx dirett.
  • Tpoġġix fil-magna tal-ħasil tal-platti jew fil-magna tal-ħasil.
  • Tużax alkoħol jew bliċ biex tnaddaf.
Infographic showing daily care instructions for the AirFit frame system, including what to do and what to avoid.

Image: An infographic detailing the recommended daily care for the AirFit frame system, listing actions to take (replace, wipe, air dry) and actions to avoid (direct sunlight, dishwasher, alcohol/bleach).

Skeda ta' Sostituzzjoni

It is recommended to replace your AirFit F30 Frame System every 3 months to maintain optimal performance and hygiene.

Sinjali li jista’ jkun wasal iż-żmien li tissostitwixxi s-sistema tal-qafas tiegħek:

  • Qed tesperjenza tnixxijiet eċċessivi.
  • It-terapija tiegħek tħossha inqas effettiva mis-soltu.
  • Is-sistema tal-qafas tiegħek tibda turi xedd u kedd (eż., xquq, tibdil fil-kulur, telf ta' elastiċità).
Infographic recommending replacement of the frame system every 3 months and listing signs of wear.

Image: An infographic advising replacement of the frame system every 3 months, accompanied by visual cues and a list of indicators for when replacement is necessary.

Issolvi l-problemi

If you encounter issues with your AirFit F30 Frame System, consider the following:

  • Excessive Leaks:
    • Re-adjust headgear straps for a snug but not overly tight fit.
    • Inspect the cushion for signs of wear, tears, or improper seating on the frame.
    • Check the elbow connection for secure attachment and any visible damage.
  • Magnets Detaching:
    • Ensure the headgear is correctly attached to the magnetic clips.
    • If detachment occurs frequently during sleep, review your sleeping position or consider if the headgear tension needs minor adjustment.
    • Refer to the Important Safety Information regarding magnetic interference.
  • Elbow Leaks Air:
    • Ensure the elbow is fully and correctly inserted into the mask frame.
    • Inspect the elbow for any cracks or damage that could cause air leakage. If damaged, replace the elbow.

Speċifikazzjonijiet

KaratteristikaDettall
Dimensjonijiet tal-Prodott6 x 4 x 3 pulzieri
Piż tal-oġġett2.72 uqija
Numru tal-MudellAirFit F30
ManifatturResMed
ASINB09V76SDTW

Garanzija u Appoġġ

For detailed warranty information regarding your ResMed AirFit F30 Frame System, please refer to the documentation provided with your original purchase or contact ResMed directly.

For additional support, product information, or to explore other ResMed products, please visit the official ResMed store:

Visit the ResMed Store

Dokumenti Relatati - AirFit F30

Preview ResMed AirFit F30 Gwida għall-Utent tal-Makra CPAP Full Face
User guide for the ResMed AirFit F30 full face CPAP mask, detailing components, assembly, fitting, features like QuietAir technology, and performance specifications.
Preview ResMed AirFit F30i Full Face Mask User Guide and Instructions
Comprehensive user guide for the ResMed AirFit F30i full face mask, covering intended use, contraindications, fitting, cleaning, reassembly, technical specifications, and warranty information.
Preview ResMed AirTouch F20 Full Face CPAP Mask: Features & Fitting Guide
Explore the ResMed AirTouch F20 full face CPAP mask, highlighting its innovative UltraSoft memory foam cushion for superior comfort, breathable seal, and easy fitting. Learn about its modular design, quiet operation, and patient benefits.
Preview Mudell tat-Twaħħil u Gwida tad-Daqsijiet tal-Maskra ResMed AirFit F40 CPAP
Iddetermina b'mod preċiż id-daqs tal-kuxxin tal-maskra ResMed AirFit F40 CPAP tiegħek b'dan il-mudell ta' twaħħil stampabbli. Jinkludi struzzjonijiet u gwidi viżwali għal twaħħil u kumdità ottimali.
Preview Gwida għall-Immuntar tal-Maskra tal-Wiċċ Sħiħ ResMed AirFit F20
Gwida dwar kif titwaħħal il-Maskra tal-Wiċċ Sħiħ ResMed AirFit F20, inklużi struzzjonijiet u mudell li jista' jiġi pprintjat biex jiġi ddeterminat id-daqs korrett tal-kuxxin.
Preview ResMed AirFit F10 Full Face Mask User Guide - Instructions and Specifications
Comprehensive user guide for the ResMed AirFit F10 full face mask. Includes instructions for fitting, cleaning, troubleshooting, technical specifications, and component details. Designed for positive airway pressure therapy.