The TRU COMPONENTS TC-9539292 is a robust and durable LED signal column designed for industrial applications. It provides clear visual and audible indications for various operational states. This manual provides essential information for the safe and effective installation, operation, and maintenance of your signal column.

TRU COMPONENTS TC-9539292 LED Signal Column with red and green light segments and attached power cable.

Image: TRU COMPONENTS TC-9539292 LED Signal Column. This image displays the TRU COMPONENTS TC-9539292 LED Signal Column. The column features two distinct light segments: an upper red segment and a lower green segment. A black power cable with exposed wires at the end is shown coiled next to the column, indicating its electrical connection. The base of the signal column includes a threaded section for mounting.

Informazzjoni dwar is-Sigurtà

Dejjem osserva l-prekawzjonijiet ta' sigurtà li ġejjin biex tevita korrimenti u ħsara lill-apparat:

  • Ensure the power supply is disconnected before installation, maintenance, or troubleshooting.
  • Installation should only be performed by qualified personnel in accordance with local electrical codes and regulations.
  • Do not expose the device to excessive moisture, dust, or extreme temperatures outside its specified operating range.
  • Ivverifika l-vol korretttage (24 Volts) before connecting the device.
  • Tippruvax timmodifika jew issewwi l-apparat int stess. Irreferi għal persunal tas-servizz kwalifikat.

Setup u Installazzjoni

Follow these steps for proper installation of the signal column:

  1. Immuntar: The signal column features a threaded base (M2x15, Hexagonal head style) for secure mounting. Ensure the mounting surface is stable and capable of supporting the device's weight (119 grams).
  2. Wiring: Connect the signal column to a 24 Volt power supply. The cable includes multiple wires; refer to the specific wiring diagram provided with your equipment for correct connections to control the red and green LED segments and the audible alarm. Ensure all connections are secure and insulated.
  3. Konsiderazzjonijiet Ambjentali: Install the column in an environment that is free from excessive vibration and within the recommended operating temperature range. The material is plastic.

Istruzzjonijiet Operattivi

The TRU COMPONENTS signal column offers both visual and audible indications:

  • Indikazzjoni Viżwali: The red and green LED segments can be configured for either continuous illumination or iteptep. The specific control signals for these modes will depend on your system's integration.
  • Audible Indication: The integrated sounder can produce either a ton kontinwu jew a discontinuous tone (intermittent sound). Consult your system's control logic for activating these audible alerts.

The signal column is designed to integrate with industrial control systems to provide real-time status updates.

Manutenzjoni

The TRU COMPONENTS signal column is designed for durability and requires minimal maintenance. However, regular checks can extend its lifespan and ensure reliable operation:

  • Tindif: Periodically clean the exterior of the column with a soft, damp drapp. Tużax tindif jew solventi li joborxu.
  • Spezzjoni: Regularly inspect the wiring and connections for any signs of wear, damage, or loose connections. Ensure the mounting is secure.
  • Verifika tal-LED: Verify that both red and green LED segments illuminate correctly when activated.
  • Sounder Check: Confirm the sounder functions as expected when activated.

Dejjem skonnettja l-enerġija qabel ma tagħmel xi manutenzjoni.

Issolvi l-problemi

If you encounter issues with your signal column, refer to the following common problems and solutions:

ProblemaKawża PossibbliSoluzzjoni
Ebda dawl jew ħossNo power supply; Incorrect wiring; Faulty unitCheck power connection (24V); Verify wiring against diagram; Contact support if power and wiring are correct.
Only one LED segment illuminatesIncorrect wiring for specific segment; Faulty LED segmentCheck wiring for the non-illuminating segment; If wiring is correct, the segment may be faulty.
Sounder not workingIncorrect wiring for sounder; Faulty sounderVerify sounder wiring; If wiring is correct, the sounder may be faulty.
Operazzjoni intermittentiLoose connections; Unstable power supplyCheck all wiring connections for tightness; Ensure power supply is stable.

For issues not listed above, or if solutions do not resolve the problem, please contact TRU Components customer support.

Speċifikazzjonijiet

Numru tal-MudellTC-9539292
ManifatturKOMPONENTI TRU
Dimensjonijiet (L x W x H)10 x 10 x 15 ċm
Piż119 gramma
KulurAħmar, Aħdar
MaterjalPlastik
Voltage24 Volts
Numru ta' Biċċiet1
Tip ta' KapEżagonali
Sistema ta' KejlMetriku
Daqs tal-ħajt1/4"-20 UNC
KaratteristiċiContinuous or flashing illumination, Continuous or discontinuous sounder

Garanzija u Appoġġ

TRU Components provides a Disponibbiltà ta' sentejn għal spare parts for the TC-9539292 LED Signal Column from the date of purchase.

For technical support, warranty claims, or further assistance, please contact your point of purchase or visit the official TRU Components website. Ensure you have your model number (TC-9539292) and purchase details ready when contacting support.

Dokumenti Relatati - TC-9539292

Preview Skeda tad-Data tad-Dawl tas-Sinjal LED USB TRU COMPONENTS
Dejta teknika u struzzjonijiet dwar it-tħaddim għad-Dawl tas-Sinjal LED USB TRU COMPONENTS (Nru. tal-oġġett 2804760), b'7 kuluri u funzjonalità ta' buzzer.
Preview Manwal tal-Utent u Speċifikazzjonijiet Tekniċi tat-Trasformatur LED TRU Components
Manwal komprensiv għall-utent u speċifikazzjonijiet tekniċi għat-transformers LED ta' TRU Components, inklużi n-numri tal-mudelli, id-dejta elettrika, il-kundizzjonijiet tat-tħaddim, u l-linji gwida tas-sigurtà għal applikazzjonijiet tad-dawl LED fuq ġewwa.
Preview Dejta Teknika u tas-Sigurtà tal-Provvista tal-Enerġija tal-Ferrovija DIN tal-Komponenti TRU
Istruzzjonijiet komprensivi dwar is-sigurtà, l-użu maħsub, spjegazzjonijiet tas-simboli, u speċifikazzjonijiet tekniċi għall-Provvisti tal-Enerġija DIN Rail ta' TRU Components, inklużi n-numri tal-mudelli u l-parametri operattivi.
Preview TRU KOMPONENTI DIN-rail Voedingen Gebruiksaanwijzing mt Speċifikazzjonijiet
Gedetailleerde gebruiksaanwijzing en technische specifications voor TRU KOMPONENTI DIN-rail voedingen. Bevat installie-instructions, veiligheidsinformatie en modelgegevens għal diversi uitvoeringen.
Preview TRU COMPONENTS Provvista tal-Enerġija DIN Rail - Manwal tal-Utent u Speċifikazzjonijiet
Istruzzjonijiet komprensivi dwar l-operat u speċifikazzjonijiet tekniċi għal TRU COMPONENTS DIN Rail Power Supplies, li jkopru s-sigurtà, l-installazzjoni, u dejta dettaljata tal-prodott. Jinkludi numri tal-mudelli, karatteristiċi elettriċi, dimensjonijiet, u linji gwida dwar is-sigurtà.
Preview Manwal tal-Utent u Speċifikazzjonijiet tal-Provvista tal-Enerġija DIN Rail ta' TRU COMPONENTS
Manwal komprensiv għall-utent u speċifikazzjonijiet tekniċi għall-provvisti tal-enerġija DIN rail ta' TRU COMPONENTS, inklużi l-mudelli tas-serje DPN, DPS, u DPH. Ikopri l-użu maħsub, l-istruzzjonijiet tas-sigurtà, l-installazzjoni, it-tindif, u l-ispeċifikazzjonijiet elettriċi u fiżiċi dettaljati.