1. Matulview
The SINOTIMER TM618 timer module is designed to automatically control the power supply to various electrical apparatus, such as streetlights, neon signs, billboards, and other appliances, based on a preset time schedule. This digital timer switch features a rechargeable internal battery to maintain program settings during power outages.

Figura 1.1: Quddiem view of the TM618 Timer Module.
2. Karatteristiċi ewlenin
- Disinn kompatt u li jiffranka l-ispazju.
- Engineered with advanced digital timing technology.
- High functionality for precise time control.
- Built-in rechargeable battery for program retention.
- Multiple ON/OFF programs for weekly scheduling.
3. Setup u Installazzjoni
3.1. Dijagramma tal-Wajers
Proper wiring is crucial for the safe and correct operation of the TM618 timer module. Refer to the diagram below for connection details. Ensure power is disconnected before performing any wiring.

Figure 3.1: Wiring Terminals and Specifications.
- Input (200-250VAC): Connect your main power supply to terminals 1 and 2.
- Output (16 AMP / 250VAC, 20 AMP @30 VDC): Terminals 3, 4, and 5 are for the controlled output. Terminal 3 is common, Terminal 4 is normally open (NO), and Terminal 5 is normally closed (NC). Connect your load to the appropriate terminals based on your application (e.g., between 3 and 4 for normally off, turning on when timed).
3.2. Initial Power-Up and Battery
Upon initial power-up, the timer's internal rechargeable battery (40mAh) will begin charging. This battery saves your programmed settings during power interruptions. Allow the unit to be powered for at least 30 minutes for the battery to gain sufficient charge before programming or disconnecting power.

Figure 3.2: Internal 40mAh Rechargeable Battery.

Figure 3.3: TM618 Operating Voltage (220V AC shown).
4. Istruzzjonijiet Operattivi
The TM618 timer allows for precise control with up to 16 ON/OFF programs per day or week. The buttons on the front panel are used for setting the time and programs.

Figure 4.1: Timer Module with Manual.
4.1. Issettjar tal-Ħin Kurrenti
- Agħfas il- ARLOĠĠ button and hold it.
- Waqt li żżomm ARLOĠĠ, agħfas ĠIMGĦA biex tissettja l-ġurnata kurrenti tal-ġimgħa.
- Waqt li żżomm ARLOĠĠ, agħfas SIEGĦA biex tissettja s-siegħa kurrenti.
- Waqt li żżomm ARLOĠĠ, agħfas MIN biex tissettja l-minuta kurrenti.
- Irrilaxxa l- ARLOĠĠ buttuna. Il-ħin issa huwa ssettjat.
4.2. Programmazzjoni tal-Ħinijiet ON/OFF
It-tajmer jappoġġja sa 16 programm ON/OFF. Kull programm jikkonsisti minn ħin ON u ħin OFF.
- Agħfas il- PROGRAMM Agħfas il-buttuna darba. Id-displej se juri "1 ON".
- Agħfas ĠIMGĦA to select the day(s) for this program (e.g., MO, TU, WE, TH, FR, SA, SU, or combinations like MO-FR, SA-SU, MO-SA, etc.).
- Agħfas SIEGĦA biex tissettja s-siegħa mixgħula mixtieqa.
- Agħfas MIN biex tissettja l-minuta ON mixtieqa.
- Agħfas PROGRAMM għal darb'oħra. Id-displej se juri "1 OFF".
- Irrepeti l-passi 2-4 biex tissettja l-ġurnata(jiet), is-siegħa u l-minuta mixtieqa ta' MITFIJA għal dan il-programm.
- Agħfas PROGRAMM to advance to the next program ("2 ON") or to exit programming mode if no more programs are needed.
- To clear a program, press IFAKKAR filwaqt li viewing the specific ON or OFF program you wish to clear.
4.3. Override Manwali
Agħfas il- MANWAL button to cycle through different operating modes:
- AUTO ON: The timer is currently ON and will follow the programmed schedule.
- AUTO OFF: The timer is currently OFF and will follow the programmed schedule.
- FUQ: The timer is forced ON, overriding any programs.
- MITFI: The timer is forced OFF, overriding any programs.
4.4. Recall Function
Il- IFAKKAR button (often marked 'R' or 'RESET') is used to clear specific program settings or to reset the timer. A small pinhole button (R) is typically used for a full reset, which clears all programs and resets the time.
5. Manutenzjoni
5.1. Kura tal-batterija
The TM618 features a built-in rechargeable battery. To ensure its longevity and proper function, keep the timer connected to power for regular charging. If the timer is stored for extended periods without power, the battery may discharge, requiring a full charge upon reconnection.
5.2. Tindif
Clean the exterior of the timer module with a soft, dry cloth. Do not use abrasive cleaners or solvents, as these can damage the plastic casing or display. Ensure no liquids enter the device.
6 Issolvi l-problemi
- Il-wiri huwa vojt: Check power connections. Ensure the unit has been powered for at least 30 minutes to charge the internal battery.
- Programmi mhux qed jiġu esegwiti: Verify that the current time is set correctly. Check that the timer is in "AUTO ON" or "AUTO OFF" mode, not forced ON/OFF. Review your programmed ON/OFF times for accuracy.
- Timer not responding to buttons: Perform a full reset using the small 'R' pinhole button. If issues persist, ensure proper power supply.
7. Speċifikazzjonijiet
| Attribut | Valur |
|---|---|
| Isem tad-Ditta | Sinotimer |
| Numru tal-Mudell | TM618N-2 (Item model number: WN-5KCF-8SVQ) |
| Input Voltage | 200-250VAC |
| Kapaċità tal-Output | 16 AMP / 250VAC, 20 AMP @30 VDC |
| Numru ta' Programmi | 16 ON/OFF programs |
| Medda ta' Żmien | Minuta sa 168 siegħa (7 ijiem) |
| Batterija Interna | 40mAh rikarikabbli |
| Materjal | Plastik |
| Kulur | Abjad |
| Dimensjonijiet tal-Prodott | 25 x 18 x 8 ċm; 11 g |
7.1. Dimensjonijiet

Figure 7.1: Front Dimensions.

Figure 7.2: Side Dimensions.
8. Garanzija u Appoġġ
For information regarding product warranty, technical support, or service, please refer to the documentation provided with your purchase or contact your retailer. Keep your proof of purchase for any warranty claims.