1. Introduzzjoni

This instruction manual provides essential information for the safe and effective use of your Invacare Low Homecare Full-Electric Bed, Model 5410LOW. This bed is designed to offer comfort and convenience in a homecare setting, featuring motorized adjustments for various bed positions. Please read this manual thoroughly before assembly, operation, or maintenance to ensure proper usage and to prevent injury or damage.

Important Note: This product is intended solely for homecare use and is NOT a hospital bed.

2. Informazzjoni dwar is-Sigurtà

Your safety is paramount. Adhere to all warnings and instructions provided in this manual. Failure to do so may result in serious injury or damage to the product.

Prekawzjonijiet Ġenerali tas-Sigurtà:

  • Always ensure the bed is placed on a stable, level surface.
  • Keep the area around the bed clear of obstructions.
  • Do not allow children or unauthorized persons to operate the bed controls.
  • Ensure all electrical cords are properly routed to prevent tripping hazards or damage.
  • Regularly inspect the bed for any signs of wear, damage, or loose components.
  • Taqbiżx il-kapaċità ta 'piż massimu ta' 350 lbs.
  • Dan il-prodott fih kimiċi magħrufa mill-Istat ta’ Kalifornja li jikkawżaw kanċer u difetti fit-twelid jew ħsara riproduttiva oħra.

3. Karatteristiċi tal-prodott

The Invacare Low Homecare Full-Electric Bed is engineered with several features to enhance user comfort and safety:

  • Full-Electric Adjustments: Motorized controls allow for independent adjustment of the upper body, knee sections, and overall bed height.
  • Low Bed Profile: Designed to minimize the risk of injury from falls, offering a lower minimum height.
  • Kostruzzjoni Durabbli: Features reinforced steel sections and high-impact bed ends for extended product lifespan.
  • Operazzjoni tal-Mutur kwieta: Electrical components are designed for quiet performance, with a waterproof enclosed motor.
  • Waterproof Hand Pendant: Ergonomic and easy to clean, ensuring reliable operation.
  • Split-Spring Design: Facilitates easier delivery and assembly by a single person.
  • Kapaċità tal-piż: Jappoġġja individwi sa 350 lbs.
Invacare Low Homecare Full-Electric Bed in a home setting with a user and caregiver.

Figure 3.1: The Invacare Low Homecare Full-Electric Bed in use, demonstrating its integration into a home environment.

Diagram of Invacare bed frame highlighting features like double insulation, casters, thermal overload protection, 350lb weight capacity, washable electronics, crank through motors, and durable rubber pendant.

Figure 3.2: Key features of the Invacare bed frame, including safety and operational components.

4. Setup u Assemblea

The Invacare Low Homecare Full-Electric Bed is designed for straightforward assembly. It is recommended that two people perform the assembly for ease and safety.

Passi tal-Assemblea:

  1. Ħoll il-Komponenti: Neħħi l-partijiet kollha mill-imballaġġ bir-reqqa. Ivverifika li l-komponenti kollha elenkati fil-lista tal-imballaġġ huma preżenti.
  2. Arma l-Qafas tas-Sodda: Connect the head and foot sections to the main bed frame. The split-spring design allows for easier handling. Ensure all connections are secure.
  3. Install Motors: Attach the motors to their designated positions on the bed frame.
  4. Qabbad il-Komponenti Elettriċi: Plug in the motor cables to the control box. Ensure all connections are firm and correctly seated. The electrical components are double-insulated for safety.
  5. Attach Hand Pendant: Connect the hand pendant to the control box.
  6. Position Bed: Move the assembled bed to its desired location. Ensure the locking casters on the head section and steering lock casters on the foot section are engaged to prevent unintended movement.
  7. Test Inizjali: Plug the bed into a grounded electrical outlet. Use the hand pendant to test all functions (head up/down, knee up/down, bed height up/down) before placing a mattress or user on the bed.
Invacare bed frame showing the adjustable head and foot sections.

Figure 4.1: The adjustable bed frame, illustrating the head and foot sections.

Close-up of the Invacare bed's electrical connection panel with color-coded ports.

Figure 4.2: Detail of the electrical connection panel, showing color-coded ports for easy setup.

5. Istruzzjonijiet Operattivi

The Invacare Low Homecare Full-Electric Bed is operated using the ergonomic hand pendant.

Hand Pendant Functions:

Invacare hand pendant with buttons for adjusting bed positions.

Figure 5.1: The Invacare hand pendant for bed adjustments.

  • Head Section Adjustment: Press and hold the designated buttons to raise or lower the head section of the bed.
  • Knee Section Adjustment: Press and hold the designated buttons to raise or lower the knee section of the bed.
  • Bed Height Adjustment: Press and hold the designated buttons to raise or lower the entire bed frame vertically.
  • Combined Adjustments: Some pendants may offer buttons for simultaneous adjustment of head and knee sections for a comfortable seated position.

Release the button once the desired position is reached. The quiet motor ensures minimal disturbance during adjustments.

6. Manutenzjoni

Regular maintenance ensures the longevity and safe operation of your Invacare bed.

Tindif:

  • Disconnect the bed from the power outlet before cleaning.
  • Wipe down the bed frame and bed ends with a damp drapp u deterġent ħafif. Evita cleaners li joborxu.
  • The hand pendant and enclosed motor are waterproof and can be cleaned with a damp drapp. Tgħaddasx.
  • Ensure all surfaces are dry before reconnecting to power.

Spezzjoni:

  • Periodically check all electrical cords for fraying or damage.
  • Inspect all nuts, bolts, and fasteners for tightness. Tighten if necessary.
  • Ensure casters roll freely and locks engage properly.
  • Check for any unusual noises during operation, which may indicate a need for professional service.

7 Issolvi l-problemi

This section addresses common issues you might encounter with your Invacare bed.

ProblemaKawża PossibbliSoluzzjoni
Is-sodda ma taħdimx.Power cord unplugged; circuit breaker tripped; loose electrical connection.Check power cord connection; reset circuit breaker; ensure all motor and pendant connections are secure.
One section (head/knee/height) does not move.Motor cable for that section is loose or disconnected; motor malfunction.Check the specific motor cable connection to the control box. If issue persists, contact support.
Bed makes unusual noises during operation.Loose components; motor issue.Inspect for loose bolts or frame components. If noise continues, discontinue use and contact support.
Qawwa outage.L-ebda enerġija elettrika.In case of power failure, the bed features crank-through motors allowing for manual adjustment. Consult the specific instructions for manual operation if needed.

If you encounter a problem not listed here or if the suggested solutions do not resolve the issue, please contact Invacare Customer Support.

8. Speċifikazzjonijiet

KaratteristikaDettall
Numru tal-Mudell5410BAXXA
Dimensjonijiet tal-Prodott (Ġenerali)88 inches (L) x 36 inches (W) x 9.5-20 inches (H, adjustable)
Sleep Surface Dimensions80 pulzier (L) x 36 pulzier (W)
Kapaċità tal-piż350 lbs.
Piż tal-Prodott170 Liri
ManifatturInvacare

9. Garanzija u Appoġġ

Invacare stands behind the quality of its products. For specific warranty details, please refer to the warranty card included with your product or visit the official Invacare websit.

Appoġġ għall-Klijent:

For technical assistance, troubleshooting, or warranty inquiries, please contact Invacare Customer Support:

Telefon: 1 (800) 333-6900

Please have your model number (5410LOW) and purchase information ready when contacting support.

Dokumenti Relatati - 5410BAXXA

Preview Truf tas-Sodda - Manwali, Sħiħ / Semi Elettriċi 5301IVC Lista tal-Partijiet
Lista dettaljata tal-partijiet u informazzjoni dwar l-assemblaġġ għas-sodda 5301IVC Bed Ends, sodda manwali, sħiħa, jew semi-elettrika. Tinkludi n-numri tal-partijiet, id-deskrizzjonijiet, u l-kwantitajiet għal kull assemblaġġ għall-komponenti tat-tarf tar-ras u tas-saqajn.
Preview Katalgu tal-Partijiet tas-Sodod Invacare Homecare: Mudelli Manwali, Semi-Elettriċi, Elettriċi Sħaħ u Barjatriċi
Katalogu komprensiv tal-partijiet għal Sodod Invacare HomeCare, inklużi mudelli Manwali, Semi-Elettriċi, Elettriċi Sħaħ, u Bariatriċi bħal CareGuard. Sib in-numri tal-partijiet u l-ispeċifikazzjonijiet għas-sodod Invacare.
Preview Invacare Bed Rail Entrapment Risk Notification Guide | Safety Information and Warnings
Comprehensive guide from Invacare detailing the risks of bed rail entrapment, safety precautions, benefits, and user guidelines for medical beds. Includes warnings and recommendations from the FDA.
Preview Manwal tal-Utent tal-Invacare Medley Ergo u Medley Ergo Low
Dan il-manwal tal-utent jipprovdi struzzjonijiet komprensivi għas-sodod mediċi Invacare Medley Ergo u Medley Ergo Low. Ikopri linji gwida essenzjali dwar is-sigurtà, proċeduri ta' installazzjoni, dettalji operattivi, skedi ta' manutenzjoni, passi għas-soluzzjoni tal-problemi, u speċifikazzjonijiet tekniċi biex jiġi żgurat użu sikur u effettiv tas-sodod mediċi.
Preview Manwal tal-Utent tas-Sodda tal-Isptar Invacare Medley Ergo & Medley Ergo Low
Dan il-manwal tal-utent jipprovdi struzzjonijiet komprensivi għas-sodod tal-isptar elettriċi Invacare Medley Ergo u Medley Ergo Low. Ikopri informazzjoni essenzjali dwar is-sigurtà, it-twaqqif, it-tħaddim, il-manutenzjoni, is-soluzzjoni tal-problemi, u l-ispeċifikazzjonijiet tekniċi biex jiżgura użu xieraq u sikur tal-prodott.
Preview Invacare Medley Ergo Bed User Manual - Safety, Setup, Operation & Maintenance
Comprehensive user manual for the Invacare Medley Ergo and Medley Ergo Low electric hospital beds. Covers setup, operation, safety guidelines, maintenance, troubleshooting, and technical specifications.